Influence of Different Mesh Filter Module Configurations on Effluent Quality and Long-Term Filtration Performance
详细信息    查看全文
  • 作者:Christian Loderer ; Anna W枚rle ; Werner Fuchs
  • 刊名:Environmental Science & Technology (ES&T)
  • 出版年:2012
  • 出版时间:April 3, 2012
  • 年:2012
  • 卷:46
  • 期:7
  • 页码:3844-3850
  • 全文大小:371K
  • 年卷期:v.46,no.7(April 3, 2012)
  • ISSN:1520-5851
文摘
Recently, a new type of wastewater treatment system became the focus of scientific research: the mesh filter activated sludge system. It is a modification of the membrane bioreactor (MBR), in which a membrane filtration process serves for sludge separation. The main difference is that a mesh filter is used instead of the membrane. The effluent is not of the same excellent quality as with membrane bioreactors due to the much lager pore sizes of the mesh. Nevertheless, it still resembles the quality of currently used standard treatment system, the activated sludge process. The new process shows high future potential as an alternative where a small footprint of these plants is required (3 times lower footprint than conventional activated sludge systems because of neglecting the secondary clarifier and reducing the biological stage). However, so far only limited information on this innovative process is available. In this study, the effect of different pore sizes and different mesh module configurations on the effluent quality was investigated varying the parameters cross-flow velocity (CFV) and flux rate. Furthermore the long-term filtration performance was studied in a pilot reactor system and results were compared to the full-scale conventional activated sludge process established at the same site. The results demonstrate that the configuration of the filter module has little impact on effluent quality and is only of importance with regard to engineering aspects. Most important for a successful operation are the hydrodynamic conditions within the filter module. The statement 鈥渢he higher the pore size the higher the effluent turbidity鈥?was verified. Excellent effluent quality with suspended solids between 5 and 15 mg L鈥? and high biological elimination rates (chemical oxygen demand (COD) 90鈥?5%, biological oxygen demand (BOD5) 94鈥?8%, total nitrogen (TN) 70鈥?0%, and ammonium nitrogen (NH4-N) 95鈥?9%) were achieved and also compared to those of conventional activated sludge systems. Regarding the air requirement for module aeration, which is the main cost factor in MBR technology, an astonishing optimization could be achieved. During the long-term filtration experiments only 4 N m3/m3 was necessary to keep a stable filtration process for more than 3 weeks (MBR 20鈥?0 N m3/m3).

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700