Effect of heat loads and ambient conditions on thermal comfort for single-sided ventilation
详细信息    查看全文
  • 作者:David Park (1)
    Francine Battaglia (1)

    1. Department of Mechanical Engineering
    ; Virginia Tech ; Blacksburg ; VA ; 24061 ; USA
  • 关键词:single ; sided ventilation ; natural ventilation ; thermal comfort ; building energy
  • 刊名:Building Simulation
  • 出版年:2015
  • 出版时间:April 2015
  • 年:2015
  • 卷:8
  • 期:2
  • 页码:167-178
  • 全文大小:3,214 KB
  • 参考文献:1. Allocca, C, Chen, Q, Glicksman, LR (2003) Design analysis of single-sided natural ventilation. Energy and Buildings 35: pp. 785-795 CrossRef
    ANSYS FLUENT 12.0 User鈥檚 Guide. Ansys Inc, Canonsburg, PA, USA
    ASHRAE Standard 55-2010 Thermal Environment Standards for Human Occupancy. American Society of Heating, Refrigerating and Air Conditioning Engineers, Atlanta, GA, USA
    2. Awbi, HB (2003) Ventilation of Buildings. Spon Press, London
    3. Brodrick, JR, Westphalen, D (2001) Uncovering auxiliary energy use. ASHRAE Journal 43: pp. 58
    4. Cheuong, JOP, Liu, CH (2011) CFD simulations of natural ventilation behaviour in high-rise buildings in regular and staggered arrangements at various spacings. Energy and Buildings 43: pp. 1149-1158 CrossRef
    5. Cho, YJ, Awbi, HB (2007) A study of the effect of heat source location in a ventilated room using multiple regression analysis. Building and Environment 42: pp. 2072-2082 CrossRef
    6. Chow, WK, Li, J (2007) Numerical simulations on thermal plumes with k-蓻 types of tubulence models. Building and Environment 42: pp. 2819-2828 CrossRef
    7. El-Agouz, SA (2008) The effect of internal heat source and opening locations on environmental natural ventilation. Energy and Buildings 40: pp. 409-418 CrossRef
    8. Emmerich, SJ, Dols, WS, Axley, JW (2001) Natural Ventilation Review and Plan for Design and Analysis Tools. National Institue of Standards Technology, NISTIR 6781.
    9. Feng, J, Xu, Z, Jie, Y (2008) Natural ventilation potential analysis of office building in China. Journal of Tongji University 36: pp. 92-96
    10. Gan, G (2000) Effective depth of fresh air distribution in rooms with single-sided natural ventilation. Energy and Buildings 31: pp. 65-73 CrossRef
    11. Incropera, FP, Witt, DP, Bergman, TL, Lavine, AS (2007) Fundamentals of Heat and Mass Transfer. John Wiley and Sons, New York
    Quickspecs. HP L1908w 19-inch Widescreen LCD Monitor.
    12. Kaye, NB, Hunt, GR (2010) The effect of floor heat source area on the induced airflow in a room. Building and Environment 45: pp. 839-847 CrossRef
    Compact Refrigerator: 46-94683/9.
    13. Larsen, TS, Heiselberg, P (2008) Single-sided natural ventilation driven by wind pressure and temperature difference. Energy and Buildings 40: pp. 1031-1040 CrossRef
    14. Mahajan, BM (1987) Measurement of interzonal heat and mass transfer by natural convection. Solar Energy 38: pp. 437-466 CrossRef
    15. Patankar, SV (1980) Numerical Heat Transfer and Fluid Flow. Hemisphere Publishing, New York
    16. Ravikumar, P, Prakash, D (2009) Analysis of thermal comfort in an office room by varying the dimensions of the windows on adjacent walls using CFD: A case study based on numerical simulation. Building Simulation 2: pp. 187-196 CrossRef
    17. RIBA Royal Institue of British Architects (2014). Available at http://www.architecture.com/SustainabilityHub/Designstrategies/Air/1-2-1-2-Naturalventilation-stackventilation.aspx.
    18. Roache, PJ (1994) Perspective: A method for uniform reporting of grid refinement studies. ASME Journal of Fluids Engineering 116: pp. 405-413 CrossRef
    19. Schaelin, A, Moser, A, Mass, J (1992) Simulation of airflow through large openings in buildings. ASHRAE Transactions 98: pp. 319-328
    20. Starakakis, GM, Vrachopoulos, M, Markatos, NC, Koukou, MK (2008) Natural cross-ventilation in buildings: Building-scale experiments, numerical simulation and thermal comfort evaluation. Energy and Buildings 40: pp. 1666-1681 CrossRef
    21. Stoakes, P, Battaglia, F, Passe, U (2011) Predicting natural ventilation flows in whole buildings. Part 1: The Viipuri Library. Building Simulation 4: pp. 263-276 CrossRef
    22. Stoakes, P, Battaglia, F, Passe, U (2011) Predicting natural ventilation flows in whole buildings. Part 2: The Esherick House. Building Simulation 4: pp. 365-377 CrossRef
    Annual Energy Review 2007.
    International Energy Outlook 2013.
    23. Mass, J (1992) Air flow through large openings in buildings. Energy Conservation in Buildings and Community Systems Programme Annex 20 Technical Report (Subtask 2: Air Flows between Zones).
    24. Villi, G, Pasut, W, Carli, M (2009) CFD modeling and thermal performance analysis of a wooden ventilated roof structure. Building Simulation 2: pp. 215-228 CrossRef
  • 刊物类别:Engineering
  • 刊物主题:Building Construction, HVAC and Refrigeration
    Engineering Thermodynamics and Transport Phenomena
    Atmospheric Protection, Air Quality Control and Air Pollution
    Environmental Computing and Modeling
    Chinese Library of Science
  • 出版者:Tsinghua University Press, co-published with Springer-Verlag GmbH
  • ISSN:1996-8744
文摘
Natural ventilation is an effective method to save energy required to condition buildings and to improve indoor air quality. Designing a naturally ventilated building is a greater challenge than designing a mechanically ventilated building because natural ventilation highly depends on weather, which changes continuously. Another factor that may alter air movement and thermal conditions in the building is the presence of heat loads and furniture. The objective of the current study is to examine the effects of various environmental conditions and room configurations on both airflow distribution and thermal conditions in a room. In this study computational fluid dynamics (CFD) was used to model single-sided buoyancy-driven ventilation in a room with a door. Experimental and numerical data from the literature were used to initially validate the CFD, and the results agreed fairly well. Various heat loads and furniture were added to the room to examine their effects on airflow stratification and thermal conditions. Overall, the conditions in a room were not significantly affected by additional heat sources. Lastly, cooler ambient conditions at the doorway were modeled, and the room was unable to achieve comfortable thermal conditions.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700