Retrograde Closure of Perimembranous Ventricular Septal Defect Using Muscular Ventricular Septal Occluder: A Single-Center Experience of a Novel Technique
详细信息    查看全文
  • 作者:Kalyanasundaram Muthusamy
  • 关键词:Ventricular septal defect ; Amplatzer muscular VSD device ; Cera Lifetech muscular VSD device ; Antegrade technique ; Retrograde technique ; Arteriovenous looping
  • 刊名:Pediatric Cardiology
  • 出版年:2015
  • 出版时间:January 2015
  • 年:2015
  • 卷:36
  • 期:1
  • 页码:106-110
  • 全文大小:653 KB
  • 参考文献:1. Bass JL, Karla GS, Arora R et al (2003) Initial human experience with the Amplatzer perimembranous ventricular septal occluder device. Catheter Cardiovasc Interv 58:238-45 CrossRef
    2. Fu YC, Bass J, Amin Z et al (2006) Transcatheter closure of perimembranous ventricular septal defects using the new Amplatzer membranous VSD occluder. Results of the U.S. phase I trial. J Am Coll Cardiol 47:319-25 CrossRef
    3. Gu X, Han YM, Titus JL et al (2000) Transcatheter closure of membranous ventricular septal defects with a new nitinol prosthesis in a natural swine model. Catheter Cardiovasc Interv 50:502-09 CrossRef
    4. Hijazi ZM, Hakim F, Abu Haweleh A et al (2002) Catheter closure of perimembranous ventricular septal defects using new Amplatzer membranous VSD occluder: initial clinical experience. Catheter Cardiovasc Interv 56:508-15 CrossRef
    5. Holzer R, de Giovanni J, Walsh KP et al (2006) Transcatheter closure of perimembranous ventricular septal defects using the Amplatzer membranous VSD occluder: immediate and midterm results of an international registry. Catheter Cardiovasc Interv 68:620-28 CrossRef
    6. Kramoh E, Dahdah N, Fournier A et al (2008) Invasive measurements of atrioventricular conduction parameters prior to and following ventricular septal defect closure with the Amplatzer device. J Invasive Cardiol 20:212-16
    7. Masura J, Gao W, Gavora P et al (2005) Percutaneous closure of perimembranous ventricular septal defects with the eccentric Amplatzer device: multicenter follow- up study. Pediatric Cardiol 26:216-19 CrossRef
    8. Miro J, Hosking M, Lee KJ, et al (2005) Closure of perimembranous ventricular septal defects with the Amplatzer device: multicenter Canadian experience. Pediatric interventional cardiac symposium and emerging new technologies in congenital heart surgery (PICS/ENTICHS-2005), Buenos Aires, 15-8 September 2005
    9. Pedra CAC, Pedra SRF, Esteves CA et al (2004) Percutaneous closure of perimembranous ventricular septal defects with the Amplatzer device: technical and morphological considerations. Catheter Cardiovasc Interv 61:403-10 CrossRef
    10. Pinto RJ, Dalvi BV, Sharma S (2006) Transcatheter closure of perimembranous ventricular septal defects using Amplatzer asymmetric ventricular septal defect occluder: preliminary experience with 18-month follow up. Catheter Cardiovasc Interv 68:145-52 CrossRef
    11. Rigby ML, Redington AN (1994) Primary transcatheter closure of perimembranous ventricular septal defects. Br Heart J 72:368-71 CrossRef
    12. Thanopoulos BD, Rigby ML, Karanasios E et al (2007) Transcatheter closure of perimembranous ventricular septal defects in infants and children using the Amplatzer perimembranous ventricular septal defect occluder. Am J Cardiol 99:984-89 CrossRef
    13. Yip WCL, Zimmerman F, Hijazi ZM (2005) Heart block and empirical therapy after transcatheter closure of perimembranous ventricular septal defect. Catheter Cardiovasc Interv 66:436-41 CrossRef
  • 刊物类别:Medicine
  • 刊物主题:Medicine & Public Health
    Cardiology
    Cardiac Surgery
    Vascular Surgery
  • 出版者:Springer New York
  • ISSN:1432-1971
文摘
We herein report the advantages of retrograde ventricular septal defect (VSD) closure using a muscular VSD device for perimembranous VSDs. Perimembranous VSDs are conventionally closed by an antegrade technique (arteriovenous looping technique) using a patent ductus arteriosus or asymmetric perimembranous VSD device. However, we used a symmetrical muscular VSD device in all cases described in this report. Use of the antegrade technique for the first few patients with VSD resulted in prolonged procedural and fluoroscopic times and frequent slippage of the device into the right ventricle. Subsequent use of the retrograde technique shortened the procedural time and allowed for easier closure of the perimembranous VSD. We performed retrograde closure of perimembranous VSDs using a symmetrical muscular VSD device in 130 patients. We obtained a high rate of successful deployment (88.5?%) and a low rate of complications (6.0?%). We also achieved shorter procedural and fluoroscopic times than those associated with the antegrade technique.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700