Multi-channel PMMA microfluidic biosensor with integrated IDUAs for electrochemical detection
详细信息    查看全文
  • 作者:Nongnoot Wongkaew (1) (2)
    Peng He (2)
    Vanessa Kurth (2)
    Werasak Surareungchai (1)
    Antje J. Baeumner (2)
  • 关键词:Microfluidic chip ; Multi ; channel ; Electrochemical biosensor ; Ultramicroelectrode ; PMMA
  • 刊名:Analytical and Bioanalytical Chemistry
  • 出版年:2013
  • 出版时间:July 2013
  • 年:2013
  • 卷:405
  • 期:18
  • 页码:5965-5974
  • 全文大小:470KB
  • 参考文献:1. Choi S, Goryll M, Sin LYM, Wong PK, Chae J (2011) Microfluidic-based biosensors toward point-of-care detection of nucleic acids and proteins. Microfluid Nanofluid 10:231-47 CrossRef
    2. Lien KY, Lee GB (2010) Miniaturization of molecular biological techniques for gene assay. Analyst 135:1499-518 CrossRef
    3. Selvaganapathy PR, Carlen ET, Mastrangelo CH (2003) Recent progress in microfluidic devices for nucleic acid and antibody assays. Proc IEEE 91:954-75 CrossRef
    4. Noh J, Kim HC, Chung TD (2011) Biosensors in microfluidic chips. Top Curr Chem 304:117-52 CrossRef
    5. Hervás M, López MA, Escarpa A (2012) Electrochemical immunosensing on board microfluidic chip platforms. TrAC-Trend Anal Chem 31:109-28 CrossRef
    6. Mir M, Homs A, Samitier J (2009) Integrated electrochemical DNA biosensors for lab-on-a-chip devices. Electrophoresis 30:3386-397 CrossRef
    7. Sassa F, Morimoto K, Satoh W, Suzuki H (2008) Electrochemical techniques for microfluidic applications. Electrophoresis 29:1787-800 CrossRef
    8. Amatore C, Da Mota N, Sella C, Thouin L (2008) General concept of high-performance amperometric detector for microfluidic (bio)analytical chips. Anal Chem 80:4976-985 CrossRef
    9. Chen SP, Wu J, Yu XD, Xu JJ, Chen HY (2010) Preparation of metal nanoband microelectrode on poly(dimethylsiloxane) for chip-based amperometric detection. Anal Chim Acta 665:152-59 CrossRef
    10. Do J, Ahn CH (2008) A polymer lab-on-a-chip for magnetic immunoassay with on-chip sampling and detection capabilities. Lab Chip 8:542-49 CrossRef
    11. Gao Y, Bhattacharya S, Chen X, Barizuddin S, Gangopadhyay S, Gillis KD (2009) A microfluidic cell trap device for automated measurement of quantal catecholamine release from cells. Lab Chip 9:3442-446 CrossRef
    12. Ordeig O, Ortiz P, Mu?oz-Berbel X, Demming S, Büttgenbach S, Fernández-Sánchez C, Llobera A (2012) Dual photonic-electrochemical lab on a chip for online simultaneous absorbance and amperometric measurements. Anal Chem 84:3546-553 CrossRef
    13. Wang Y, Luo J, Chen H, He Q, Gan N, Li T (2008) A microchip-based flow injection-amperometry system with mercaptopropionic acid modified electroless gold microelectrode for the selective determination of dopamine. Anal Chim Acta 625:180-87 CrossRef
    14. Yamaguchi A, Jin P, Tsuchiyama H, Masuda T, Sun K, Matsuo S, Misawa H (2002) Rapid fabrication of electrochemical enzyme sensor chip using polydimethylsiloxane microfluidic channel. Anal Chim Acta 468:143-52 CrossRef
    15. Niwa O, Morita M, Tabei H (1990) Electrochemical behavior of reversible redox species at interdigitated array electrodes with different geometries: consideration of redox cycling and collection efficiency. Anal Chem 62:447-52 CrossRef
    16. Hintsche R, Paeschke M, Woflenberger U, Schnakenberg U, Wagner B, Lisec T (1994) Microelectrode arrays and application to biosensing devices. Biosens Bioelectron 9:697-05 CrossRef
    17. Heo JI, Shim DS, Teixidor GT, Oh S, Madou MJ, Shin H (2011) Carbon interdigitated array nanoelectrodes for electrochemical applications. J Electrochem Soc 158:J76–J80 CrossRef
    18. Min J, Baeumner AJ (2004) Characterization and optimization of interdigitated ultramicroelectrode arrays as electrochemical biosensor transducers. Electroanalysis 16:724-29 CrossRef
    19. Goral VN, Zaytseva NV, Baeumner AJ (2006) Electrochemical microfluidic biosensor for the detection of nucleic acid sequences. Lab Chip 6:414-21 CrossRef
    20. Kwakye S, Goral VN, Baeumner AJ (2006) Electrochemical microfluidic biosensor for nucleic acid detection with integrated minipotentiostat. Biosens Bioelectron 21:2217-223 CrossRef
    21. Bunyakul N, Edwards KA, Promptmas C, Baeumner AJ (2009) Cholera toxin subunit B detection in microfluidic devices. Anal Bioanal Chem 393:177-86 CrossRef
    22. Nugen SR, Asiello PJ, Connelly JT, Baeumner AJ (2009) PMMA biosensor for nucleic acids with integrated mixer and electrochemical detection. Biosens Bioelectron 24:2428-433 CrossRef
    23. Benhabib M, Chiesl TN, Stockton AM, Seherer JR, Mathies RA (2010) Multichannel capillary electrophoresis microdevice and instrumentation for in situ planetary analysis of organic molecules and biomarkers. Anal Chem 82:2372-379 CrossRef
    24. Chen SP, Wu J, Yu XD, Xu JJ, Chen HY (2010) Multi-parameter detection of diabetes mellitus on multichannel poly(dimethylsiloxane) analytical chips coupled with nanoband microelectrode arrays. Electrophoresis 31:3097-106 CrossRef
    25. Ding X, Lin SCS, Lapsley MI, Li S, Guo X, Chan CY, Chiang IK, Wang L, McCoy JP, Huang TJ (2012) Standing surface acoustic wave (SSAW) based multichannel cell sorting. Lab Chip 12:4228-231 CrossRef
    26. Gao Y, Shen Z, Wang H, Dai Z, Lin B (2005) Chiral separations on multichannel microfluidic chips. Electrophoresis 26:4774-779 CrossRef
    27. Irawan R, Tjin SC, Fang X, Fu CY (2007) Integration of optical fiber light guide, fluorescence detection system, and multichannel disposable microfluidic chip. Biomed Microdevices 9:413-19 CrossRef
    28. Kim SJ, Gobi KV, Iwasaka H, Tanaka H, Miura N (2007) Novel miniature SPR immunosensor equipped with all-in-one multi-microchannel sensor chip for detecting low-molecular-weight analytes. Biosens Bioelectron 23:701-07 CrossRef
    29. Pan X, Jiang L, Liu K, Lin Bingcheng B, Qin Jianhua J (2010) A microfluidic device integrated with multichamber polymerase chain reaction and multichannel separation for genetic analysis. Anal Chim Acta 674:110-15 CrossRef
    30. Shadpour H, Hupert ML, Patterson D, Liu C, Galloway M, Stryjewski W, Goettert J, Soper SA (2007) Multichannel microchip electrophoresis device fabricated in polycarbonate with an integrated contact conductivity sensor array. Anal Chem 79:870-78 CrossRef
    31. Siew Bang C, Skinner CD, Taylor J, Attiya S, Lee WE, Picelli G, Harrison DJ (2001) Development of a multichannel microfluidic analysis system employing affinity capillary electrophoresis for immunoassay. Anal Chem 73:1472-479 CrossRef
    32. Wu MS, Shi HW, He LJ, Xu JJ, Chen HY (2010) Microchip device with 64-site electrode array for multiplexed immunoassay of cell surface antigens based on electrochemiluminescence resonance energy transfer. Anal Chem 84:4207-213 CrossRef
    33. Ymeti A, Kanger JS, Greve J, Besselink GAJ, Lambeck PV, Wijn R, Heideman RG (2005) Integration of microfluidics with a four-channel integrated optical Young interferometer immunosensor. Biosens Bioelectron 20:1417-421 CrossRef
    34. Moreira NH, De Jesus De Almeida AL, De Oliveira Piazzeta MH, De Jesus DP, Deblire A, Gobbi AL, Fracassi Da Silva JA (2009) Fabrication of a multichannel PDMS/glass analytical microsystem with integrated electrodes for amperometric detection. Lab Chip 9:115-21 CrossRef
    35. Nugen SR, Asiello PJ, Baeumner AJ (2009) Design and fabrication of a microfluidic device for near-single cell mRNA isolation using a copper hot embossing master. Microsyst Technol 15:477-83 CrossRef
    36. Connelly JT, Nugen SR, Borejsza-Wysocki W, Durst RA, Montagna RA, Baeumner AJ (2008) Human pathogenic / Cryptosporidium species bioanalytical detection method with single oocyst detection capability. Anal Bioanal Chem 391:487-95 CrossRef
    37. Baeumner AJ, Humiston MC, Montagna RA, Durst RA (2001) Detection of viable oocysts of / Cryptosporidium parvum following nucleic acid sequence-based amplification. Anal Chem 73:1176-180 CrossRef
  • 作者单位:Nongnoot Wongkaew (1) (2)
    Peng He (2)
    Vanessa Kurth (2)
    Werasak Surareungchai (1)
    Antje J. Baeumner (2)

    1. School of Bioresources and Technology, King Mongkut’s University of Technology Thonburi, Bangkhuntien, Bangkok, 10150, Thailand
    2. Department of Biological and Environmental Engineering, Cornell University, 202 Riley Robb Hall, Ithaca, NY, 14853, USA
文摘
A novel multi-channel poly(methyl methacrylate) (PMMA) microfluidic biosensor with interdigitated ultramicroelectrode arrays (IDUAs) for electrochemical detection was developed. The focus of the development was a simple fabrication procedure and the realization of a reliable large IDUA that can provide detection simultaneously to several microchannels. As proof of concept, five microchannels are positioned over a large single IDUA where the channels are parallel with the length of the electrode finger. The IDUAs were fabricated on the PMMA cover piece and bonded to a PMMA substrate containing the microfluidic channels using UV/ozone-assisted thermal bonding. Conditions of device fabrication were optimized realizing a rugged large IDUA within a bonded PMMA device. Gold adhesion to the PMMA, protective coatings, and pressure during bonding were optimized. Its electrochemical performance was studied using amperometric detection of potassium ferri and ferro hexacyanide. Cumulative signals within the same chip showed very good linearity over a range of 0-8?μM (R 2--.98) and a limit of detection of 3.48?μM. The bonding of the device was optimized so that no cross talk between the channels was observed which otherwise would have resulted in unreliable electrochemical responses. The highly reproducible signals achieved were comparable to those obtained with separate single-channel devices. Subsequently, the multi-channel microfluidic chip was applied to a model bioanalytical detection strategy, i.e., the quantification of specific nucleic acid sequences using a sandwich approach. Here, probe-coated paramagnetic beads and probe-tagged liposomes entrapping ferri/ferro hexacyanide as the redox marker were used to bind to a single-stranded DNA sequence. Flow rates of the non-ionic detergent n-octyl-β-d-glucopyranoside for liposome lysis were optimized, and the detection of the target sequences was carried out coulometrically within 250?s and with a limit of detection of 12.5?μM. The robustness of the design and the reliability of the results obtained in comparison to previously published single-channel designs suggest that the multi-channel device offers an excellent opportunity for bioanalytical applications that require multianalyte detection and high-throughput assays. Figure Multi-channel microfluidic biosensor with integrated IDUAs for a sandwich nucleic acid hybridization assay

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700