Cardiac MR Elastography: Comparison with left ventricular pressure measurement
详细信息    查看全文
  • 作者:Thomas Elgeti (1)
    Michael Laule (2)
    Nikola Kaufels (1)
    J?rg Schnorr (1)
    Bernd Hamm (1)
    Abbas Samani (3) (4)
    Jürgen Braun (5)
    Ingolf Sack (1)
  • 刊名:Journal of Cardiovascular Magnetic Resonance
  • 出版年:2009
  • 出版时间:December 2009
  • 年:2009
  • 卷:11
  • 期:1
  • 全文大小:1173KB
  • 参考文献:1. Sengupta PP, Krishnamoorthy VK, Korinek J, Narula J, Vannan MA, Lester SJ, Tajik JA, Seward JB, Khandheria BK, Belohlavek M: Left ventricular form and function revisited: applied translational science to cardiovascular ultrasound imaging. / J Am Soc Echocardiogr 2007, 20 (5) : 539-51. CrossRef
    2. Axel L: Biomechanical dynamics of the heart with MRI. / Annu Rev Biomed Eng 2002, 4: 321-47. CrossRef
    3. Finn JP, Nael K, Deshpande V, Ratib O, Laub G: Cardiac MR imaging: state of the technology. / Radiology 2006, 241 (2) : 338-54. CrossRef
    4. Beek AM, Bondarenko O, Afsharzada F, van Rossum AC: Quantification of late gadolinium enhanced CMR in viability assessment in chronic ischemic heart disease: a comparison to functional outcome. / J Cardiovasc Magn Reson 2009, 11 (1) : 6. CrossRef
    5. Kass DA: Assessment of diastolic dysfunction. Invasive modalities. / Cardiol Clin 2000, 18 (3) : 571-86. CrossRef
    6. Strobeck JE, Sonnenblick EH: Myocardial and ventricular function. Part II: Intact heart. / Herz 1981, 6 (5) : 275-87.
    7. Mandinov L, Eberli FR, Seiler C, Hess OM: Diastolic heart failure. / Cardiovasc Res 2000, 45 (4) : 813-25. CrossRef
    8. Muthupillai R, Lomas DJ, Rossman PJ, Greenleaf JF, Manduca A, Ehman RL: Magnetic resonance elastography by direct visualization of propagating acoustic strain waves. / Science 1995, 269 (5232) : 1854-857. CrossRef
    9. Rump J, Klatt D, Braun J, Warmuth C, Sack I: Fractional encoding of harmonic motions in MR elastography. / Magn Reson Med 2007, 57 (2) : 388-95. CrossRef
    10. Elgeti T, Rump J, Hamhaber U, Papazoglou S, Hamm B, Braun J, Sack I: Cardiac magnetic resonance elastography. Initial results. / Invest Radiol 2008, 43 (11) : 762-72. CrossRef
    11. Sack I, Rump J, Elgeti T, Samani A, Braun J: MR elastography of the human heart: noninvasive assessment of myocardial elasticity changes by shear wave amplitude variations. / Magn Reson Med 2009, 61 (3) : 668-77. CrossRef
    12. Klatt D, Asbach P, Rump J, Papazoglou S, Somasundaram R, Modrow J, Braun J, Sack I: In vivo determination of hepatic stiffness using steady-state free precession magnetic resonance elastography. / Invest Radiol 2006, 41 (12) : 841-48. CrossRef
    13. Papazoglou S, Xu C, Hamhaber U, Siebert E, Bohner G, Klingebiel R, Braun J, Sack I: Scatter-based magnetic resonance elastography. / Phys Med Biol 2009, 54 (7) : 2229-241. CrossRef
    14. Burkhoff D, Mirsky I, Suga H: Assessment of systolic and diastolic ventricular properties via pressure-volume analysis: a guide for clinical, translational, and basic researchers. / Am J Physiol Heart Circ Physiol 2005, 289 (2) : H501-12. CrossRef
    15. Magorien DJ, Shaffer P, Bush CA, Magorien RD, Kolibash AJ, Leier CV, Bashore TM: Assessment of left ventricular pressure-volume relations using gated radionuclide angiography, echocardiography, and micromanometer pressure recordings. A new method for serial measurements of systolic and diastolic function in man. / Circulation 1983, 67 (4) : 844-53.
    16. Oh JK, Tajik J: The return of cardiac time intervals: the phoenix is rising. / J Am Coll Cardiol 2003, 42 (8) : 1471-474. CrossRef
  • 作者单位:Thomas Elgeti (1)
    Michael Laule (2)
    Nikola Kaufels (1)
    J?rg Schnorr (1)
    Bernd Hamm (1)
    Abbas Samani (3) (4)
    Jürgen Braun (5)
    Ingolf Sack (1)

    1. Department of Radiology, Charité - Universit?tsmedizin Berlin, Campus Mitte, Charitéplatz 1, 10117, Berlin, Germany
    2. Department of Medicine (Cardiology, Angiology, Pulmonology), Charité - Universit?tsmedizin Berlin, Campus Mitte, Berlin, Germany
    3. Department of Medical Biophysics, University of Western Ontario, Ontario, Canada
    4. Department of Electrical and Computer Engineering, University of Western Ontario, Ontario, Canada
    5. Institute of Medical Informatics, Charité - Universit?tsmedizin Berlin, Campus Benjamin Franklin, Hindenburgdamm 30, 12200, Berlin, Germany
文摘
Purpose of study To compare magnetic resonance elastography (MRE) with ventricular pressure changes in an animal model. Methods Three pigs of different cardiac physiology (weight, 25 to 53 kg; heart rate, 61 to 93 bpm; left ventricular [LV] end-diastolic volume, 35 to 70 ml) were subjected to invasive LV pressure measurement by catheter and noninvasive cardiac MRE. Cardiac MRE was performed in a short-axis view of the heart and applying a 48.3-Hz shear-wave stimulus. Relative changes in LV-shear wave amplitudes during the cardiac cycle were analyzed. Correlation coefficients between wave amplitudes and LV pressure as well as between wave amplitudes and LV diameter were determined. Results A relationship between MRE and LV pressure was observed in all three animals (R2 ?0.76). No correlation was observed between MRE and LV diameter (R2 ?0.15). Instead, shear wave amplitudes decreased 102 ± 58 ms earlier than LV diameters at systole and amplitudes increased 175 ± 40 ms before LV dilatation at diastole. Amplitude ratios between diastole and systole ranged from 2.0 to 2.8, corresponding to LV pressure differences of 60 to 73 mmHg. Conclusion Externally induced shear waves provide information reflecting intraventricular pressure changes which, if substantiated in further experiments, has potential to make cardiac MRE a unique noninvasive imaging modality for measuring pressure-volume function of the heart.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700