APMP Scale Comparison with Three Radiation Thermometers and Six Fixed-Point Blackbodies
详细信息    查看全文
  • 作者:Y. Yamada ; Y. Shimizu ; J. Ishii
  • 关键词:Calibration and measurement capability ; Fixed ; point blackbody ; International comparison ; Radiation thermometry scale ; Size ; of ; source effect
  • 刊名:International Journal of Thermophysics
  • 出版年:2015
  • 出版时间:August 2015
  • 年:2015
  • 卷:36
  • 期:8
  • 页码:1813-1824
  • 全文大小:425 KB
  • 参考文献:1.F. Sakuma, Metrologia, 47, Tech. Suppl. 03002 (2010)
    2.F. Sakuma, S.N. Park, M. Ballico, L. Wang, Z. Yuan, Metrologia, 44, Tech. Suppl. 03003 (2007)
    3.The BIPM Key Comparison Database (Bureau International des Poids et Mesures-BIPM, S猫vres, France), http://鈥媖cdb.鈥媌ipm.鈥媜rg/鈥?/span> . Accessed 2 Feb 2015
    4.M.J. de Groot, E.W.M. van der Ham, R. Monshouwer, CCT-K5: Comparison of Local Realizations of the ITS-90 Between the Silver Point and 1700 \(^{\circ }\) C Using Vacuum Tungsten Strip Lamps as Transfer Standards, Final Report (Bureau International des Poids et Mesures-BIPM, S猫vres, France, 2008), http://鈥媖cdb.鈥媌ipm.鈥媜rg/鈥婣ppendixB/鈥媋ppbresults/鈥媍ct-k5/鈥媍ct-k5_鈥媐inal_鈥媟eport.鈥媝df . Accessed 2 Feb 2015
    5.IR-RST Series Standard Radiation Thermometers (Chino Corp. Tokyo, Japan), http://鈥媤ww.鈥媍hino.鈥媍o.鈥媕p/鈥媏nglish/鈥媝roducts/鈥媡raceability/鈥媔r-rst.鈥媓tml . Accessed 2 Feb 2015
    6.F. Sakuma, L. Ma, T. Kobayashi, A. Nakanishi, in Proceedings SICE Annual Conference 2004, Sapporo (Society of Instrument and Control Engineers, Tokyo, 2004), pp. 72鈥?6
    7.F. Sakuma, L. Ma, T. Kobayashi, Int. J. Thermophys. 29, 312 (2008)CrossRef ADS
    8.K. Hiraka, Y. Yamada, J. Ishii, H. Oikawa, T. Shimizu, S. Kadoya, T. Kobayashi, in Proceedings of Ninth International Temperature Symposium (Los Angeles), Temperature: Its Measurement and Control in Science and Industry, vol. 8, ed. by C.W. Meyer, AIP Conference Proceedings 1552 (AIP, Melville, NY, 2013), pp. 300鈥?04
    9.K. Hiraka, Y. Yamada, J. Ishii, H. Oikawa, T. Shimizu, S. Kadoya, T. Kobayashi, inProceedings SICE Annual Conference 2012, Akita (Society of Instrument and Control Engineers, Tokyo, 2012), pp. 35鈥?9
    10.Y. Yamada, Y. Wang, Acta Metrol. Sin. 29, 46 (2008)
    11.F. Sakuma, L. Ma, in聽Proceedings SICE-ICASE International Joint Conference 2006, Busan (Society of Instrument and Control Engineers, Tokyo, 2006), pp. 3336鈥?341
    12.Y. Shimizu, J. Ishii, Int. J. Thermophys. 32, 2560 (2011)CrossRef ADS
    13.Y. Shimizu, J. Ishii, F. Sakuma, A. Ono, in Proceedings of TEMPMEKO 2004, 9th International Symposium on Temperature and Thermal Measurements Industry and Science, ed. by D. Zvizdi膰, L.G. Bermanec, T. Veliki, T. Sta拧i膰 (FSB/LPM, Zagreb, Croatia, 2004), pp. 509鈥?14
    14.J. Ishii, Y. Yamada, N. Sasajima, Y. Shimizu, in Proceedings of Ninth International Temperature Symposium (Los Angeles), Temperature: Its Measurement and Control in Science and Industry, vol. 8, ed. by C.W. Meyer, AIP Conference Proceedings 1552 (AIP, Melville, NY, 2013), pp. 666鈥?71
    15.N. Sasajima, Y. Yamada, B.M. Zailani, K. Fan, A. Ono, in Proceedings of TEMPMEKO 2001, 8th International Symposium on Temperature and Thermal Measurements Industry and Science, ed. by B. Fellmuth, J. Seidel, G. Scholz (VDE Verlag, Berlin, 2002), pp. 501鈥?06
    16.P. Bloembergen, in Proceedings of TEMPMEKO 鈥?9, 7th International Symposium on Temperature and Thermal Measurements Industry and Science, ed. by J.F. Dubbeldam, M.J. de Groot (Edauw Johannissen bv, Delft, 1999), pp. 607鈥?12
    17.Y. Yamada, Y. Wang, Y. Shimizu, K. Minahiro, in聽Proceedings SICE Annual Conference 2013, Nagoya (Society of Instrument and Control Engineers, Tokyo, 2013), pp. 389鈥?94
    18.J. Fischer, M. Battuello, M. Sadli, M. Ballico, S.N. Park, P. Saunders, Y. Zundong, B. Carol Johnson, E. van der Ham, W. Li, F. Sakuma, G. Machin, N. Fox, S. Ugur, M. Matveyev, CCT-WG5 on Radiation Thermometry鈥擴ncertainty Budgets for Realisation of Scales by Radiation Thermometry, CCT Document CCT/03-03 (Bureau International des Poids et Mesures-BIPM, S猫vres, France, 2003), http://鈥媤ww.鈥媌ipm.鈥媜rg/鈥媍c/鈥婥CT/鈥婣llowed/鈥?2/鈥婥CT03-03.鈥媝df . Accessed 2 Feb 2015
    19.J. Fischer, P. Saunders, M. Sadli, M. Battuello, C.W. Park, Z. Yuan, H. Yoon, L. Wang, E. van der Ham, F. Sakuma, Y. Yamada, M. Ballico, G. Machin, N. Fox, J. Hollandt, M. Matveyev, P. Bloembergen, S. Ugur, CCT-WG5 on Radiation Thermometry鈥擴ncertainty Budgets for Calibration of Radiation Thermometers below the Silver Point, Version 1.71, Final Version (Bureau International des Poids et Mesures-BIPM, S猫vres, France, 2008), http://鈥媤ww.鈥媌ipm.鈥媜rg/鈥媤g/鈥婥CT/鈥婥CT-WG5/鈥婣llowed/鈥婱iscellaneous/鈥婰ow_鈥婽_鈥婾ncertainty_鈥婸aper_鈥媀ersion_鈥?.鈥?1.鈥媝df . Accessed 2 Feb 2015
    20.M.G. Cox, Metrologia 39, 589 (2002)CrossRef ADS MATH
    21.Radiation Thermometry Review Protocol (Bureau International des Poids et Mesures-BIPM, S猫vres, France, 2010), http://鈥媤ww.鈥媌ipm.鈥媜rg/鈥媤g/鈥婥CT/鈥婥CT-WG-CMC/鈥婣llowed/鈥婥MC_鈥婻eview_鈥婸rotocols/鈥婥MC-03-Radiation_鈥婽hermometry_鈥婻eview_鈥婸rotocol_鈥婻ev1_鈥?010_鈥?5_鈥?7_鈥媠p.鈥媝df . Accessed 2 Feb 2015
  • 作者单位:Y. Yamada (1)
    Y. Shimizu (1)
    J. Ishii (1)

    1. National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, 305-8563, Japan
  • 刊物类别:Physics and Astronomy
  • 刊物主题:Physics
    Condensed Matter
    Mechanics
    Industrial Chemistry and Chemical Engineering
    Physical Chemistry
  • 出版者:Springer Netherlands
  • ISSN:1572-9567
文摘
New Asia Pacific Metrology Programme (APMP) comparisons of radiation thermometry standards, APMP TS-11, and -12, have recently been initiated. These new APMP comparisons cover the temperature range from \(156\,^{\circ }\hbox {C}\) to \(2800\, ^{\circ }\hbox {C}\). Three radiation thermometers with central wavelengths of 1.6 \(\upmu \hbox {m}\), 0.9 \(\upmu \hbox {m}\), and 0.65 \(\upmu \hbox {m}\) are the transfer devices for the radiation thermometer scale comparison conducted in the so-called star configuration. In parallel, a compact fixed-point blackbody furnace that houses six types of fixed-point cells of In, Sn, Zn, Al, Ag, and Cu is circulated, again in a star-type comparison, to substantiate fixed-point calibration capabilities. Twelve APMP national metrology institutes are taking part in this endeavor, in which the National Metrology Institute of Japan acts as the pilot. In this article, the comparison scheme is described with emphasis on the features of the transfer devices, i.e., the radiation thermometers and the fixed-point blackbodies. Results of preliminary evaluations of the performance and characteristic of these instruments as well as the evaluation method of the comparison results are presented. Keywords Calibration and measurement capability Fixed-point blackbody International comparison Radiation thermometry scale Size-of-source effect