A preliminary study of an image synthesis method to simulate the change in the incident X-ray spectrum by using thickness information
详细信息    查看全文
  • 作者:Seokmin Han ; Kihwan Choi ; Sang Wook Yoo
  • 关键词:Image synthesis ; Imaging parameters ; Mmammography ; Calibration ; Thickness ; Additive noise
  • 刊名:Journal of the Korean Physical Society
  • 出版年:2016
  • 出版时间:March 2016
  • 年:2016
  • 卷:68
  • 期:6
  • 页码:815-820
  • 全文大小:799 KB
  • 参考文献:[1]P. Massoumzadeh, S. Don, C. Hildebolt, K. Bae and B. Whiting, Med. Phys 36, 174 (2009).CrossRef
    [2]A. Bankier, C. Schaefer-Prokop, V. De Maertelaer, D. Tack, P. Jaksch, W. Klepetko and P. Gevenois, Radiology 242, 898 (2007).CrossRef
    [3]D. Frush, C. Slack, C. Hollingsworth, G. Bisset, L. Donnelly, J. Hsieh, T. Lavin-Wensell and J. Mayo, Am. J. Roentgenol. 179, 1107 (2002).CrossRef
    [4]B. Karmazyn, D. Frush, K. Applegate, C. Maxfield, M. Cohen and R. Jones, Am. J. Roentgenol. 192, 143 (2009).CrossRef
    [5]D. Tack, V. De Maertelaer, W Petit, P. Scillia, P. Muller, C. Suess and P. Gevenois, Radiology 236, 318(2005).CrossRef
    [6]R. van Gelder et al., Radiology 224, 25 (2002).CrossRef
    [7]R. van Gelder et al., Radiology 232, 611 (2004).CrossRef
    [8]Adam S. Wang and Norbert J. Pelc, Med. Phys. 38, 5551 (2011).CrossRef
    [9]Robert S. Saunders, and Ehsan Samei, Med. Phys. 30, 3006 (2003).CrossRef
    [10]Steven Don et al., in proceedings of SPIE 6142, Medical Imaging 2006 (San Diego, CA, February 11, 2006).
    [11]A. Svalkvist and M. Bth, Med. Phys. 37, 258 (2010).CrossRef
    [12]A. Mackenzie, D. R. Dance, A. Workman, M. Yip, K. Wells and K. C. Young, Med. Phys. 39, 2721 (2012).CrossRef
    [13]M. Bth, M. Hkansson, A. Tingberg and L. G. Mnsson, Radiat. Prot. Dosim. 114, 253 (2005).CrossRef
    [14]S. Han, D.-G. Kang, S. Kim, H. H. Oh, Y. H. Sung and S. D. Lee, in proceedings of IEEE NSS-MIC 2010 (Knoxville, TN, Oct. 30 - Nov. 6, 2010), p. 2822.
    [15]T. S. Curry, J. E. Dowdey and R. C. Murry, Christensen’s physics of diagnostic radiology (Lippincott Williams & Wilkins, 1990).
  • 作者单位:Seokmin Han (1)
    Kihwan Choi (1)
    Sang Wook Yoo (1)

    1. Samsung Electronics, Suwon, 16677, Korea
  • 刊物主题:Physics, general; Theoretical, Mathematical and Computational Physics; Particle and Nuclear Physics;
  • 出版者:Springer Netherlands
  • ISSN:1976-8524
文摘
The objective of this research is to suggest an image synthesis method to simulate the change in the incident X-ray spectrum, based on knowledge of the tissue thickness. The image of a reference phantom was acquired before acquiring the image of an object under the same condition. With knowledge of the thickness of an input pixel, the mapping region could be limited to a specific thickness region in the reference phantom. Taking advantage of the relation between the reference phantom and the imaging object mapped to a limited region, we could synthesize an image acquired at a different tube current and tube voltage. The noise difference was compensated for by the addition of zero-mean Gaussian noise, and RMSE(root mean-square error) between the synthesized image and the actual image was calculated. The average noise difference between the synthesized image and the actual image was about 4.5% (ranging from 0% to 7.7%). RMSE between those images was calculated to be about 1.4% of the average pixel intensity. The calculated results indicate that the proposed method can provide a synthesized image close to the actual image.