Heat transfer coefficient and thermal losses of solar collector and Nusselt number correlation for rectangular solar air heater duct with longitudinal fins hold under the absorber plate
详细信息    查看全文
  • 作者:Foued Chabane (1)
    Noureddine Moummi (1)
    Djamel Bensahal (1)
    Abdelhafid Brima (1)
  • 刊名:Applied Solar Energy
  • 出版年:2014
  • 出版时间:January 2014
  • 年:2014
  • 卷:50
  • 期:1
  • 页码:19-26
  • 全文大小:
  • 参考文献:1. Akpinar, E.K. and Ko?yigit, F., / Int. Commun. Heat Mass, 2010, vol. 37, no. 4, pp. 416-21. CrossRef
    2. Karsli, S., / Renew. Energy, 2007, vol. 32, no. 10, pp. 1645-660. doi:10.1016/j.renene.2006.08.005 CrossRef
    3. McAdams, W., / Heat Transmission, New York: McGraw-Hill, 1954.
    4. Klein, S.A., / Solar Energy, 1975, vol. 17, pp. 79-0. CrossRef
    5. Azad, E., / Energy Sust. Develop., 2012, vol. 16, no. 1, pp. 68-3. doi:10.1016/j.esd.2011.10.006 CrossRef
    6. Saini, R.P. and Saini, J.S., / Int. J. Heat Mass Transfer, 1997, vol. 40, no. 4, pp. 973-86. CrossRef
    7. Tiwari, G.N., / Solar Energy: Fundamentals, Design Modeling and Applications, New York, New Delhi: CRC Press and Narosa Publ., 2002.
    8. Chabane, F., Moummi, N., and Benramache, S., / J. Power Technol., 2013, vol. 93, no. 1, pp. 52-8.
    9. Chabane, F., Moummi, N., and Benramache, S., / J. Adv. Res., doi:10.1016/j.jare.2013.03.001.
    10. Chabane, F., Moummi, N., Benramache, S., et al., / Int. J. Energy Technol., 2013, vol. 5, no. 8, pp. 1-.
    11. Chabane, F., Moummi, N., Benramache, S., et al., / J. Sci. Eng.
    12. Chabane, F. and Moummi, N., and Benramache, S., / Experimental Study on Heat Transfer of Solar Air Heater, Lambert Academic Publ., 2013.
  • 作者单位:Foued Chabane (1)
    Noureddine Moummi (1)
    Djamel Bensahal (1)
    Abdelhafid Brima (1)

    1. University of Biskra, Biskra, Algeria
  • ISSN:1934-9424
文摘
An experimental investigation has been carried out for a series of system and operating parameters in order to analyze the effect of mass flow rate on heat transfer and Nusselt number characteristics in solar air heater. Experiments are performed at different air mass flow rates; varying from 0.012 to 0.016 kg/s, about hot summer days of Mai 2012. Hourly values of global solar radiation and some meteorological data (temperature, wind speed, relative humidities, etc.) for measuring days are obtained from the Biskra city of Algeria. The experiments encompassed the flow Reynolds number in the range 965.48-301.4. Longitudinal fins were used inferior the absorber plate for an increase the heat exchange and render the flow fluid in the channel uniform. The effects of mass flow rate of air on the outlet temperature, Nusselt Number, Reynolds Number, Prandtl Number, the heat transfer in the thickness and length of the solar air collector were studied. For this effect was have created a new correlation correspondent of solar air collector with using fins it was written Nu = κ0Re1.36Pr?.68exp(0.342m)h [?.018Pr].