Experimental investigation of beam-to-column connection with SHN490 steel under cyclic loading
详细信息    查看全文
文摘
Seismic performance of beam-to-column connections used in the middle-low rise buildings was investigated through the cyclic loading test. Four joint specimens were prepared in accordance with the variables of material and connection type. In two cases of welded connection, the brittle fracture in weld did not occur but cracked at heat-affected zone (HAZ) and/or near weld access hole. In the connections with extended end-plate, punching failure followed by end-plate failure occurred at the flange of column around bolt head. The moment capacities based on failure modes were calculated and compared with the test results. The connections were classified as rigid, semi-rigid, flexible in terms of bending stiffness and strength.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700