Determination of cadmium(II) using carbon paste electrode modified with a Cd-ion imprinted polymer
详细信息    查看全文
  • 作者:Hamid Ashkenani (12) hamid6730@gmail.com
    Mohammad Ali Taher (1)
  • 关键词:Cd(II) – Ion ; imprinted polymer – Modified carbon paste electrode – Voltammetry – Water and food samples
  • 刊名:Microchimica Acta
  • 出版年:2012
  • 出版时间:July 2012
  • 年:2012
  • 卷:178
  • 期:1-2
  • 页码:53-60
  • 全文大小:333.4 KB
  • 参考文献:1. Liu Y, Chang X, Wang S, Yong G, Din B, Meng S (2004) Solid-phase extraction and preconcentration of cadmium(II) in aqueous solution with Cd(II)-imprinted resin (poly-Cd(II)-DAAB-VP) packed columns. Anal Chim Acta 519:173–179
    2. Singh DK, Mishra S (2009) Synthesis, characterization and removal of Cd(II) using Cd(II)-ion imprinted polymer. J Hazard Mater 164:1547–1551
    3. Yiin SJ, Chern CL, Sheu JY, Lin TH (1999) Cadmium induced lipid peroxidation in rat testes and protection by selenium. BioMetals 12:353–359
    4. Zhu X, Zhu X, Wang B (2006) Determination of trace cadmium in water samples by graphite furnace atomic absorption spectrometry after cloud point extraction. Microchim Acta 154:95–100
    5. Liang P, Li J, Yang X (2005) Cloud point extraction preconcentration of trace cadmium as 1-Phenyl-3-methyl-4-benzoyl-5-pyrazolone complex and determination by flame atomic absorption spectrometry. Microchim Acta 152:47–51
    6. Chen Z-S, Hiraide M, Kawaguchi H (1996) Preconcentration of trace heavy metals in water by coprecipitation with magnesium oxinate for electrothermal atomic absorption spectrometry. Microchim Acta 124:27–34
    7. Tokal?oglu S, Oymak T, Kartal S (2007) Coprecipitation of lead and cadmium using copper(II) mercaptobenzothiazole prior to flame atomic absorption spectrometric determination. Microchim Acta 159:133–139
    8. Jia X, Han Y, Liu X, Duan T, Chen H (2010) Dispersive liquid–liquid microextraction combined with flow injection inductively coupled plasma mass spectrometry for simultaneous determination of cadmium, lead and bismuth in water samples. Microchim Acta 171:49–56
    9. Rivas RE, López-García I, Hernández-Córdoba M (2009) Determination of traces of lead and cadmium using dispersive liquid-liquid microextraction followed by electrothermal atomic absorption spectrometry. Microchim Acta 166:355–361
    10. Taher MA (2003) Flame atomic absorption spectrometric determination of trace cadmium in alloys and biological samples after solid–liquid extraction and preconcentration with use of nitroso-S. Microchim Acta 141:101–106
    11. Xiang G, Huang Y, Luo Y (2009) Solid phase extraction of trace cadmium and lead in food samples using modified peanut shell prior to determination by flame atomic absorption spectrometry. Microchim Acta 165:237–242
    12. Suneetha Y, Naresh Kumar B, Harinath Y, Harikishore Kumar Reddy D, Seshaiah K (2011) Functionalization of cross linked chitosan with 2-aminopyridine-3-carboxylic acid for solid phase extraction of cadmium and zinc ions and their determination by atomic absorption spectrometry. Microchim Acta. doi:10.1007/s00604-011-0707-z
    13. Afkhami A, Madrakian T, Ahmadi R, Bagheri H, Tabatabaee M (2011) Chemically modified alumina nanoparticles for selective solid phase extraction and preconcentration of trace amounts of Cd(II). Microchim Acta 175:69–77
    14. Samczynski Z, Dybczynski R (2004) Ion exchange behavior of cadmium, mercury, silver and zinc on Retardion 11A8 and Chelex 100 ion exchangers in ammonia medium and its application for radiochemical separations. Microchim Acta 144:103–114
    15. Mahmood T, Saddique MT, Naeem A, Mustafa S, Dilara B, Raza ZA (2011) Cation exchange removal of Cd from aqueous solution by NiO. J Hazard Mater 85:824–834
    16. Kokkinos C, Economou A, Raptis I, Efstathiou CE (2008) Lithographically fabricated disposable bismuth-film electrodes for the trace determination of Pb(II) and Cd(II) by anodic stripping voltammetry. Electrochim Acta 53:5294–5299
    17. Cao LY, Jia JB, Wang ZH (2008) Sensitive deter- mination of Cd and Pb by differential pulse stripping voltammetry with in situ bismuth-modified zeolite doped carbon paste electrodes. Electrochim Acta 53:2177–2182
    18. Li J, Liu S, Mao X, Gao P, Yan Z (2004) Trace determination of rare earths by adsorption voltammetry at a carbon paste electrode. J Electroanal Chem 561:137–142
    19. Hu C, Wu K, Dai X, Hu S (2003) Simultaneous determination of lead(II) and cadmium(II) at a diacetyldioxime modified carbon paste electrode by differential pulse stripping voltammetry. Talanta 60:17–24
    20. Li X, Sun Y (2007) Evaluation of ionic imprinted polymers by electrochemical recognition of rare earth ions. Hydrometallurgy 87:63–71
    21. Gawin M, Konefa? J, Trzewik B, Walas S, Tobiasz A, Mrowiec H, Witek E (2010) Preparation of a new Cd(II)-imprinted polymer and its application to determination of cadmium(II) via flow-injection-flame atomic absorption spectrometry. Talanta 80:1305–1310
    22. Le?niewska B, Kosińska M, Godlewska-?y?kiewicz B, Zambrzycka E, Wilczewska AZ (2011) Selective solid phase extraction of platinum on an ion imprinted polymers for its electrothermal atomic absorption spectrometric determination in environmental samples. Microchim Acta. doi:10.1007/s00604-011-0685-1
    23. Kan X, Liu T, Zhou H, Li C, Fang B (2010) Molecular imprinting polymer electrosensor based on gold nanoparticles for theophylline recognition and determination. Microchim Acta 171:423–429
    24. Alizadeh T, Ganjali MR, Nourozi P, Zare M, Hoseini M (2011) A carbon paste electrode impregnated with Cd2+ imprinted polymer as a new and high selective electrochemical sensor for determination of ultra-trace Cd2+ in water samples. J Electroanal Chem 657:98–106
    25. Alizadeh T, Akhoundian M (2010) Promethazine determination in plasma samples by using carbon paste electrode modified with molecularly imprinted polymer (MIP): coupling of extraction, preconcentration and electrochemical determination. Electrochim Acta 55:568–5873
    26. Guo J, Chai Y, Yuan R, Song Z, Zou Z (2011) Lead (II) carbon paste electrode based on derivatized multi-walled carbon nanotubes: application to lead content determination in environmental samples. Sensors Actuators B 155:639–645
    27. Li YH, Xie HQ, Zhou FQ (2005) Alizarin violet modified carbon paste electrode for the determination of trace silver(I) by adsorptive voltammetry. Talanta 67:28–33
    28. Kalcher K, Kauffmann JM, Wang J, Svancara I, Vytras K, Neuhold C, Yang Z (1995) Sensors based on carbon paste in electrochemical analysis: a review with particular emphasis on the period 1990–1993. Electroanalysis 7:5–22
    29. Yoe JH, Jones AL (1944) Colorimetric determination of iron with Disodium-1,2-dihydroxybenzene-3,5-disulfonate. Anal Chem 16:111–115
    30. Pourreza N, Zavvar Mousavi H (2004) Determination of cadmium by flame atomic absorption spectrometry after preconcentration on naphthalene-methyltrioctylammonium chloride adsorbent as tetraiodocadmate (II) ions. Anal Chim Acta 503:279–282
    31. Dadfarnia S, Talebi M, Haji Shabani AM, Amani Beni Z (2007) Determination of lead and cadmium in different samples by flow injection atomic absorption spectrometry incorporating a microcolumn of immobilized ammonium pyrrolidine dithiocarbamate on microcrystalline naphthalene. Croat Chem Acta 80:17–23
    32. Marino G, Bergamini MF, Teixeira MFS, Cavalheiro ETG (2003) Evaluation of a carbon paste electrode modified with organofunctionalized amorphous silica in the cadmium determination in a differential pulse anodic stripping voltammetric procedure. Talanta 59:1021–1028
    33. El Mhammedi MA, Achak M, Najih R, Bakassec M, Chtaini A (2009) Micro-extraction and trace determination of cadmium by square wave voltammetry at the carbon paste electrode impregnated with Ca10(PO4)6(OH)2. Mater Chem Phys 115:567–571
    34. Yantasee W, Lin Y, Fryxell GE, Busche BJ (2004) Simultaneous detection of cadmium, copper, and lead using a carbon paste electrode modified with carbamoylphosphonic acid self-assembled monolayer on mesoporous silica. (SAMMS). Anal Chim Acta 502:207–212
    35. Janegitz BC, Figueiredo-Filho LCS, Marcolino-Junior LH, Souza SPN, Pereira-Filho ER, Fatibello-Filho O (2011) Development of a carbon nanotubes paste electrode modified with crosslinked chitosan for cadmium(II) and mercury(II) determination. J Electroanal Chem 660:209–216
    36. Hocevar SB, Svancara I, Vytras K, Ogorevc B (2005) Novel electrode for electrochemical stripping analysis based on carbon paste modified with bismuth powder. Electrochim Acta 51:706–710
    37. Tesarova E, Baldrianova L, Hocevar SB, Svancara I, Vytras K, Ogorevc B (2009) Anodic stripping voltammetric measurement of trace heavy metals at antimony film carbon paste electrode. Electrochim Acta 54:1506–1510
    38. Estevez-Hernandez O, Cisneros JLH-H, Reguera E, Naranjo-Rodríguez I (2007) On the complex formation of CdCl2 with 1-furoylthioureas: preconcentration and voltammetric behavior of Cd(II) at carbon paste electrodes modified with 3-monosubstituted and 3,3-disubstituted derivatives. Sensors Actuators B 120:766–772
    39. Ganjali MR, Asgari M, Faridbod F, Norouzi P, Badiei A, Gholami J (2010) Thiomorpholine-functionalized nanoporous mesopore as a sensing material for Cd2+ carbon paste electrode. J Solid State Electrochem 14:1359–1366
    40. Mei HYP (2008) Determination of cadmium (II) using H2O2-oxidized activated carbon modified electrode. J Appl Electrochem 38:1623–1627
  • 作者单位:1. Department of Chemistry, Shahid Bahonar University of Kerman, Kerman, Iran2. Young Researchers Society, Shahid Bahonar University of Kerman, P.O. Box 76175-133, Kerman, Iran
  • 刊物类别:Chemistry and Materials Science
  • 刊物主题:Chemistry
    Analytical Chemistry
    Inorganic Chemistry
    Physical Chemistry
    Characterization and Evaluation Materials
    Monitoring, Environmental Analysis and Environmental Ecotoxicology
  • 出版者:Springer Wien
  • ISSN:1436-5073
文摘
We have synthesized cadmium(II) ion-imprinted polymers (IIP) and non-imprinted polymers (NIP) using 1-(2-pyridylazo)-2-naphthol as a ligand. The materials were used to prepare a carbon paste electrode for the determination of Cd(II). Polymerization was performed with (a) methacrylic acid as a functional monomer, (b) ethyleneglycol dimethacrylate as the crosslinking monomer, and (c) 2,2′-azobis(isobutyronitrile) as the initiator. Imprinted cadmium ion was removed from the polymeric matrix using nitric acid. The measurements were carried out in an closed circuit after accumulation at ?1.2 V, this followed by electrolysis of the accumulated Cd(II) by voltammetric scanning from ?1.0 to ?0.6 V. The parameters governing the response of the electrode were studied. Under optimized conditions, the response of the electrode is linear in the range from 2.0 to 200 ng mL?1. The detection limit is 0.31 ng mL?1. The relative standard deviations are ±3.4 and ±2.1 % for 7 successive determinations of 20.0 and 50.0 ng mL-1 of Cd(II), respectively. The method was applied to the determination of cadmium (II) in water and food samples.