Clinical evaluation of low-power laser and a desensitizing agent on dentin hypersensitivity
详细信息    查看全文
  • 作者:Anely Oliveira Lopes ; Carlos de Paula Eduardo
  • 关键词:Dentin hypersensitivity ; Desensitizer ; Laser ; Non ; carious cervical lesion
  • 刊名:Lasers in Medical Science
  • 出版年:2015
  • 出版时间:February 2015
  • 年:2015
  • 卷:30
  • 期:2
  • 页码:823-829
  • 全文大小:160 KB
  • 参考文献:1. Orchardson R, Gangarosa LP, Holland GR et al (1994) Dentine hypersensitivity into the 21st century. Arch Oral 39:113-19 CrossRef
    2. Bartold PM (2006) Dentinal hypersensitivity: a review. Aust Dent J 51(3):212-18 CrossRef
    3. Bartlett DW, Shah P (2006) A critical review of non-carious cervical (wear) lesions and the role of abfraction, erosion, and abrasion. J Dent Res 85(4):306-2 CrossRef
    4. Lussi A (2006) Erosive tooth wear—a multifactorial condition of growing concern and increasing knowledge. Monogr Oral Sci 20:1- CrossRef
    5. Coleman TA, Grippo JO, Kinderknecht KE (2000) Cervical dentin hypersensitivity, part II: associations with abfractive lesions. Quintessence Int 31(7):466-3
    6. Walters PA (2005) Dentinal hypersensitivity: a review. J Contemp Dent Pract 6(2):107-7
    7. West NX (2008) Dentine hypersensitivity: preventive and therapeutic approaches to treatment. Periodontol 2000(48):31-1 CrossRef
    8. Ladalardo TC, Pinheiro A, Campos RAC et al (2002) Laser therapy in the treatment of dentine hypersensitivity. Braz Dent J 15(2):780-5
    9. Br?nnstr?m M (1966) Sensitivity of dentine. Oral Surgery 21(4):517-26 CrossRef
    10. Orchardson R, Gillam DG (2006) Managing dentin hypersensitivity. JADA 137(7):990-98
    11. Chabanski MB, Gillam DG (1997) Etiology, prevalence and clinical features of cervical dentin sensitivity. J Oral Rehabil 24(1):15-9 CrossRef
    12. Kakaboura A, Rahiotis C, Thomaidis S, Doukoudakis S (2005) Clinical effectiveness of two agents on the treatment of tooth cervical hypersensitivity. Am J Dent 18(4):291-95
    13. Pamir T, Dalgar H, Onal B (2007) Clinical evaluation of three desensitizing agents in relieving dentin hypersensitivity. Oper Dent 32(6):544-48 CrossRef
    14. Olusile AO, Bamise CT, Oginni AO, Dosumu OO (2008) Short-term clinical evaluation of four desensitizing agents. J Contemp Dent Pract 9(1):22-9
    15. Aranha ACC, Pimenta LA, Marchi GM (2009) Clinical evaluation of desensitizing treatments for cervical dentin hypersensitivity. Braz Oral Res 23(3):333-39 CrossRef
    16. Al-Sabbagh M, Brown A, Thomas MV (2009) In-office treatment of dentinal hypersensitivity. Dent Clin North Am 53(1):61-0 CrossRef
    17. Orsini G, Procaccini M, Manzoli L, Giuliodori F, Lorenzini A, Putignano A (2010) A double-blind randomized-controlled trial comparing the desensitizing efficacy of a new dentifrice containing carbonate/hydroxyapatite nanocrystals and a sodium fluoride/potassium nitrate dentifrice. J Clin Periodontol 37(6):510-17 CrossRef
    18. Pradeep AR, Sharma A (2010) Comparison of clinical efficacy of a dentifrice containing calcium sodium phosphosilicate to a dentifrice containing potassium nitrate and to a placebo on dentinal hypersensitivity: a randomized clinical trial. J Periodontol 81(8):1167-173 CrossRef
    19. Aranha ACC, Eduardo CP (2011) In vitro effects of Er, Cr:YSGG laser on dentine hypersensitivity. Dentine permeability and scanning electron microscopy analysis. Lasers Med Sci 27:1-
    20. Aranha ACC, Eduardo CP (2011) Effects of Er:YAG and Er, Cr:YSGG lasers on dentine hypersensitivity. Short-term clinical evaluation. Lasers Med Sci 13:1-
    21. Lopes AL, Aranha ACC (2013) Comparative evaluation of the effects of the Nd:YAG laser and a desensitizer agent on the treatment of dentin hypersensitivity. A clinical study. Photomed Laser Surg 31(3):132-38
  • 刊物类别:Medicine
  • 刊物主题:Medicine & Public Health
    Medicine/Public Health, general
    Dentistry
    Laser Technology and Physics and Photonics
    Quantum Optics, Quantum Electronics and Nonlinear Optics
    Applied Optics, Optoelectronics and Optical Devices
  • 出版者:Springer London
  • ISSN:1435-604X
文摘
The aim of this randomized, longitudinal clinical study was to evaluate different protocols for dentin hypersensitivity treatment with low-power laser at different dosages, desensitizing agent, and associations, for a period of 6?months. After analysis of the inclusion and exclusion criteria of volunteer participants, those who present pain resulting from non-carious cervical lesions were selected. Twenty-seven patients participated in the study, and 55 lesions were recorded. The lesions were divided into five groups (n--1), treated, and evaluated: G1: Gluma Desensitizer (Heraeus); G2: low-power laser (Photon Lase, DMC) at low dose (three vestibular points and one apical point of irradiation: 30?mW, 10?J/cm2, 9?s per point with wavelength of 810?nm), three sessions were performed with an interval of 72?h between them; G3: low-power laser at high dose (application at one cervical and one apical point: 100?mW, 90?J/cm2, 11?s per point with wavelength of 810?nm), three sessions were performed with an interval of 72?h between irradiations; G4: low-power laser at low dose + Gluma Desensitizer; and G5: low-power laser at high dose + Gluma Desensitizer, the level of sensitivity of each volunteer was evaluated with a visual analog scale of pain (VAS) with the use of air from a triple syringe and exploration with a probe after time intervals of 5?min, 1?week, and 1, 3, and 6?months after treatment. Data were collected and subjected to statistical analysis. Kolmogorov–Smirnov test was used to verify the distribution of the data, and nonparametric Kruskal–Wallis and Friedman tests were performed for comparison among the experimental groups and time intervals studied, respectively. Statistically significant differences between the studied time intervals (p--.05) were detected. From the difference in pain, it was observed that for both stimuli, the protocol with the Gluma desensitizing agent presented immediate effects of pain reduction. For low-level lasers, it was observed that there were distinct effects for the different doses; however, both were efficient in reducing pain up to the 6?months of clinical follow-up. Therefore, it could be concluded that all the desensitizing protocols were effective in reducing dentin hypersensitivity, but with different effects. The combination of protocols is an interesting alternative in the treatment of cervical dentin hypersensitivity.