Retention of lepirudin at the tip of a silicone catheter: a better catheter flush solution?
详细信息    查看全文
  • 作者:McDonaldK. Horne and Elizabeth Inkellis
  • 关键词:Catheter ; Flushes ; Lepirudin ; Heparin
  • 刊名:Supportive Care in Cancer
  • 出版年:2004
  • 出版时间:April 2004
  • 年:2004
  • 卷:12
  • 期:4
  • 页码:278-281
  • 全文大小:156 KB
  • 刊物类别:Medicine
  • 刊物主题:Medicine & Public Health
    Oncology
    Nursing
    Nursing Management and Research
    Pain Medicine
    Rehabilitation Medicine
  • 出版者:Springer Berlin / Heidelberg
  • ISSN:1433-7339
文摘
Because central venous catheters often become blocked by clot at their tip despite heparin flushes, a more effective anticoagulant is needed. We hypothesize that lepirudin, a recently introduced protein anticoagulant, might be more effective than heparin because of its tendency to adsorb to silicone, a commonly used catheter material. We preliminarily tested this hypothesis in vitro by measuring residual lepirudin and heparin activity at the tip of a catheter that had been submerged in a flowing stream of water for various periods of time. We observed that lepirudin is less readily removed than heparin from the catheter by fluid washing over it. This slow-release property of lepirudin might provide prolonged protection against clot formation at the catheter tip. A clinical trial will be necessary, however, to determine whether this property translates into significant improvement in catheter function.