Stability evaluation and correction of a pulsed neutron generator prompt gamma activation analysis system
详细信息    查看全文
  • 作者:Roman J. Shypailo
  • 关键词:Body composition ; Neutron activation analysis ; Nitrogen ; Humans ; Neutron generator
  • 刊名:Journal of Radioanalytical and Nuclear Chemistry
  • 出版年:2016
  • 出版时间:March 2016
  • 年:2016
  • 卷:307
  • 期:3
  • 页码:1781-1786
  • 全文大小:636 KB
  • 参考文献:1.Barzilov AP, Novikov IS, Womble PC (2012) Gamma radiation. In: Adrovic F (ed.). InTech Open Access Publisher [eBooks]. http://​www.​healthwise.​org . Accessed 24 Feb 2014
    2.Nagai T, Fujii I, Muto H, Inouye T (1969) Total-body nitrogen and protein determined by in vivo fast-neutron activation analysis. J Nucl Med 10:192–196
    3.Gierlik M, Batsch T, Moszynski M, Szczesniak T, Wolski D, Klamra W, Perot B, Perret G (2006) Comparative study of large NaI(Tl) and BGO scintillators for the EURopean illicit TRAfficking countermeasures kit project. IEEE Trans Nucl Sci 53:1737–1743CrossRef
    4.Gordon CM, Peters CW (1990) A fast-neutron probe for tomography and bulk analysis. Intern J Appl Radiat Isot 41:1111–1116CrossRef
    5.Vourvopoulos G, Womble PC (2001) Pulsed fast/thermal neutron analysis: a technique for explosives detection. Talanta 54(3):459–468CrossRef
    6.Litz M, Waits C, Mullins J (2012) Neutron-activated gamma-emission: technology review, ARL-TR-5871. Army Research Lab, Adelphi
    7.Shypailo RJ, Workeneh B, Ellis KJ (2013) Assessment of the associated particle prompt gamma neutron activation technique for total body nitrogen measurement in vivo. J Radioanal Nucl Chem 296:143–148
    8.Beddoe AH, Zuidmeer A, Hill GL (1984) A prompt gamma in vivo neutron activation analysis facility for measurement of total body nitrogen in the critically ill. Phys Med Biol 29:371–383CrossRef
    9.Chichester DL, Simpson JD, Lemchak M (2007) Advanced compact accelerator neutron generator technology for active neutron interrogation field work. J Radioanal Nucl Chem 271:629–637CrossRef
    10.Reijonen J, Gicquel F, Hahto SK, King M, Lou TP, Leung KN (2005) D-D neutron generator development at LBNL. Appl Radiat Isot 63:757–763CrossRef
    11.Fantidis JG, Nicolaou GE, Potolias C, Vordos N, Bandekas DV (2011) The comparison of four neutron sources for Prompt Gamma Neutron Activation Analysis (PGNAA) in vivo detections of boron. J Radioanal Nucl Chem 290:289–295CrossRef
    12.Danon Y (2012) Pyroelectric crystal D-D and D-T neutron generators. J Instrum 7(4):C04002. doi:10.​1088/​1748-0221/​7/​04/​C04002 CrossRef
    13.Gillich D, Kovanen A, Herman B, Fullem T, Danon Y (2009) Pyroelectric crystal neutron production in a portable prototype vacuum system. Nucl Instrum Methods Phys Res Sect A 602:306–310CrossRef
    14.Kramer GH, Burns LC, Noel L (1991) The BRMD BOMAB phantom family. Health Phys 61:895–902CrossRef
    15.Russo P, Vo D (2005) Gamma-ray detectors for nondestructive analysis. Los Alamos National Laboratory. Report LA-UR-05-3813
  • 作者单位:Roman J. Shypailo (1)

    1. Department of Pediatrics, USDA/ARS Children’s Nutrition Research Center, Baylor College of Medicine, 1100 Bates Street, Houston, TX, 77030, USA
  • 刊物类别:Chemistry and Materials Science
  • 刊物主题:Chemistry
    Nuclear Chemistry
    Physical Chemistry
    Nuclear Physics, Heavy Ions and Hadrons
    Diagnostic Radiology
    Inorganic Chemistry
  • 出版者:Akad茅miai Kiad贸, co-published with Springer Science+Business Media B.V., Formerly Kluwer Academic
  • ISSN:1588-2780
文摘
Source output stability is important for accurate measurement in prompt gamma neutron activation. This is especially true when measuring low-concentration elements such as in vivo nitrogen (~2.5 % of body weight). We evaluated the stability of the compact DT neutron generator within an in vivo nitrogen measurement system. Review of gamma event/time patterns and data from an auxiliary detector showed significant variations among repeated phantom runs. Neutron generator instability had a significant effect on measurement precision. The neutron generator used in our system must be monitored for output consistency. Adjustments must be made to measurement results to correct for generator instability.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083