Contaminants in water: non-target UHPLC/MS analysis
详细信息    查看全文
  • 作者:Fabio Gosetti ; Eleonora Mazzucco ; Maria Carla Gennaro…
  • 关键词:UHPLC ; High ; resolution mass spectrometry ; Non ; target analysis ; Unknown compounds ; Emerging contaminants ; Surface water
  • 刊名:Environmental Chemistry Letters
  • 出版年:2016
  • 出版时间:March 2016
  • 年:2016
  • 卷:14
  • 期:1
  • 页码:51-65
  • 全文大小:1,570 KB
  • 参考文献:Andreozzi R, Raffaele M, Nicklas P (2003) Pharmaceuticals in STP effluents and their solar photodegradation in aquatic environment. Chemosphere 50(10):1319–1330. doi:10.​1016/​S0045-6535(02)00769-5 CrossRef
    Berset J-D, Brenneisen R, Mathieu C (2010) Analysis of licit and illicit drugs in waste, surface and lake water samples using large volume direct injection high performance liquid chromatography–electrospray tandem mass spectrometry (HPLC-MS/MS). Chemosphere 81(7):859–866. doi:10.​1016/​j.​chemosphere.​2010.​08.​011 CrossRef
    Boreen AL, Arnold WA, McNeill K (2003) Photodegradation of pharmaceuticals in the aquatic environment: a review. Aquat Sci 65(4):320–341. doi:10.​1016/​j.​chemosphere.​2009.​09.​065 CrossRef
    Bristow AWT (2006) Accurate mass measurement for the determination of elemental formula—a tutorial. Mass Spectrom Rev 25(1):99–111. doi:10.​1002/​mas.​20058:​99-111 CrossRef
    Chiaia AC, Banta-Green C, Field J (2008) Eliminating solid phase extraction with large-volume injection LC/MS/MS analysis of illicit and legal drugs and human urine indicators in US wastewaters. Environ Sci Technol 42(23):8841–8848. doi:10.​1021/​es802309v CrossRef
    Chitescu CL, Oosterink E, de Jong J, Stolker AAML (2012) Accurate mass screening of pharmaceuticals and fungicides in water by U-HPLC–Exactive Orbitrap MS. Anal Bioanal Chem 403(10):2997–3011. doi:10.​1007/​s00216-012-5888-8 CrossRef
    Cooper HJ, Marshall AG (2001) Electrospray ionization Fourier transform mass spectrometric analysis of wine. J Agric Food Chem 49(12):5710–5718. doi:10.​1021/​jf0108516 CrossRef
    Cortés-Francisco N, Flores C, Moyano E, Caixach J (2011) Accurate mass measurements and ultrahigh-resolution: evaluation of different mass spectrometers for daily routine analysis of small molecules in negative electrospray ionization mode. Anal Bioanal Chem 400(10):3595–3606. doi:10.​1007/​s00216-011-5046-8 CrossRef
    Cunliffe JM, Maloney TD (2007) Fused-core particle technology as an alternative to sub-2-µm particles to achieve high separation efficiency with low backpressure. J Sep Sci 30(18):3104–3109. doi:10.​1002/​jssc.​200700260 CrossRef
    Cuyckens F, Hurkmans R, Castro-Perez J, Leclercq L, Mortishire-Smith RJ (2009) Extracting metabolite ions out of a matrix background by combined mass defect, neutral loss and isotope filtration. Rapid Commun Mass Spectrom 23(2):327–332. doi:10.​1002/​rcm.​3881 CrossRef
    Del Mar G-RM, Pérez-Parada A, García-Reyes JF, Fernández-Alba AR, Agüera A (2011) Use of an accurate-mass database for the systematic identification of transformation products of organic contaminants in wastewater effluents. J Chromatogr A 1218(44):8002–8012. doi:10.​1016/​j.​chroma.​2011.​09.​003 CrossRef
    Díaz R, Ibáñez M, Sancho JV, Hernández F (2011) Building an empirical mass spectra library for screening of organic pollutants by ultra-high-pressure liquid chromatography/hybrid quadrupole time-of-flight mass spectrometry. Rapid Commun Mass Spectrom 25(2):355–369. doi:10.​1002/​rcm.​4860 CrossRef
    Díaz R, Ibáñez M, Sancho JV, Hernández F (2012) Target and non-target screening strategies for organic contaminants, residues and illicit substances in food, environmental and human biological samples by UHPLC-QTOF-MS. Anal Methods 4(1):196–209. doi:10.​1039/​c1ay05385j CrossRef
    Erve JCL, Gu M, Wang Y, De Maio W, Talaat RE (2009) Spectral accuracy of molecular ions in an ltq/orbitrap mass spectrometer and implications for elemental composition determination. J Am Soc Mass Spectrom 20(11):2058–2069. doi:10.​1016/​j.​jasms.​2009.​07.​014 CrossRef
    Ferrer I, Thurman EM (2003) Liquid chromatography/time-of-flight/mass spectrometry (LC/TOF/MS) for the analysis of emerging contaminants. TrAC Trends Anal Chem 22(10):750–756. doi:10.​1016/​S0165-9936(03)01013-6 CrossRef
    Ferrer I, Fernandez-Alba A, Zweigenbaum JA, Thurman EM (2006) Exact-mass library for pesticides using a molecular-feature database. Rapid Commun Mass Spectrom 20(24):3659–3668. doi:10.​1002/​rcm.​2781 CrossRef
    Gerssen A, Muldera PPJ, de Boerb J (2011) Screening of lipophilic marine toxins in shellfish and algae: development of a library using liquid chromatography coupled to orbitrap mass spectrometry. Anal Chim Acta 685(2):176–185. doi:10.​1016/​j.​aca.​2010.​11.​036 CrossRef
    Godejohann M, Heintz L, Daolio C, Berset J-D, Muff D (2009) Comprehensive non-targeted analysis of contaminated groundwater of a former ammunition destruction site using 1H-NMR and HPLC-SPE-NMR/TOF-MS. Environ Sci Technol 43(18):7055–7061. doi:10.​1021/​es901068d CrossRef
    Gómez MJ, Gómez-Ramos MM, Malato O, Mezcua M, Férnandez-Alba AR (2010) Rapid automated screening, identification and quantification of organic micro-contaminants and their main transformation products in wastewater and river waters using liquid chromatography–quadrupole-time-of-flight mass spectrometry with an accurate-mass database. J Chromatogr A 1217(45):7038–7054. doi:10.​1016/​j.​chroma.​2010.​08.​070 CrossRef
    González-Mariño I, Quintana JB, Rodríguez I, González-Díez CR (2012) Screening and selective quantification of illicit drugs in wastewater by mixed-mode solid-phase extraction and quadrupole-time-of-flight liquid chromatography–mass spectrometry. Anal Chem 84(3):1708–1717. doi:10.​1021/​ac202989e CrossRef
    Gosetti F, Bottaro M, Gianotti V, Mazzucco E, Frascarolo P, Zampieri D, Oliveri C, Viarengo A, Gennaro MC (2010a) Sun light degradation of 4-chloroaniline in waters and its effect on toxicity. A high performance liquid chromatography–Diode array–Tandem mass spectrometry study. Environ Pollut 158(2):592–598. doi:10.​1016/​j.​envipol.​2009.​08.​012 CrossRef
    Gosetti F, Chiuminatto U, Zampieri D, Mazzucco E, Marengo E, Gennaro MC (2010b) A new on-line solid phase extraction high performance liquid chromatography tandem mass spectrometry method to study the sun light photodegradation of mono-chloroanilines in river water. J Chromatogr A 1217(20):3427–3434. doi:10.​1016/​j.​chroma.​2010.​02.​080 CrossRef
    Gosetti F, Mazzucco E, Zampieri D, Gennaro MC (2010c) Signal suppression/enhancement in high-performance liquid chromatography tandem mass spectrometry. J Chromatogr A 1217(25):3929–3937. doi:10.​1016/​j.​chroma.​2009.​11.​060 CrossRef
    Gosetti F, Mazzucco E, Gennaro MC, Marengo E (2015) Non-target UHPLC/MS analysis of emerging contaminants in water. In: Lichtfouse E et al (eds) Pollutants in buildings, water and living organisms. Springer International Publishing, Switzerland
    Hager JW (2002) A new linear ion trap mass spectrometer. Rapid Commun Mass Spectrom 16(6):512–526. doi:10.​1002/​rcm.​607 CrossRef
    Hager JW, le Blanc JCY (2002) Product ion scanning using a Q-q-Q linear ion trap (Q TRAP) mass spectrometer. Rapid Commun Mass Spectrom 17(10):1056–1064. doi:10.​1002/​rcm.​1020 CrossRef
    Hager JW, le Blanc JCY (2003) High-performance liquid chromatography–tandem mass spectrometry with a new quadrupole/linear ion trap instrument. J Chromatogr A 1020(1):3–9. doi:10.​1016/​S0021-9673(03)00426-6 CrossRef
    Ham BM (2008) Even electron mass spectrometry with biomolecule applications, 1st edn. Wiley Interscience, United States of America. ISBN: 978-0-470-11802-3
    Hernández F, Pozo ÓJ, Sancho JV, López FJ, Marín JM, Ibáñez M (2005) Strategies for quantification and confirmation of multi-class polar pesticides and transformation products in water by LC-MS2 using triple quadrupole and hybrid quadrupole time-of-flight analyzers. TrAC Trends Anal Chem 24(7):596–612. doi:10.​1016/​j.​trac.​2005.​04.​007 CrossRef
    Hernández F, Bijlsma L, Sancho JV, Díaz R, Ibáñez M (2011a) Rapid wide-scope screening of drugs of abuse, prescription drugs with potential for abuse and their metabolites in influent and effluent urban wastewater by ultra high pressure liquid chromatography–quadrupole-time-of-flight-mass spectrometry. Anal Chim Acta 684(1–2):96–106. doi:10.​1016/​j.​aca.​2010.​10.​043 CrossRef
    Hernández F, Ibáñez M, Gracia-Lor E, Sancho JV (2011b) Retrospective LC-QTOF-MS analysis searching for pharmaceutical metabolites in urban wastewater. J Sep Sci 34:3517–3526. doi:10.​1002/​jssc.​201100540 CrossRef
    Hernández F, Sancho JV, Ibáñez M, Abad E, Portolés T, Mattioli L (2012) Current use of high-resolution mass spectrometry in the environmental sciences. Anal Bioanal Chem 403:1251–1264. doi:10.​1007/​s00216-012-5844-7 CrossRef
    Herniman JM, Langley GJ, Bristow AWT, O’Connor G (2005) The validation of exact mass measurements for small molecules using FT-ICRMS for improved confidence in the selection of elemental formulas. J Am Soc Mass Spectrom 16(7):1100–1108. doi:10.​1016/​j.​jasms.​2005.​02.​027 CrossRef
    Hill DW, Kertesz TM, Fontaine D, Friedman R, Grant DF (2008) Mass spectral metabonomics beyond elemental formula: chemical database querying by matching experimental with computational fragmentation spectra. Anal Chem 80(14):5574–5582. doi:10.​1021/​ac800548g CrossRef
    Hogenboom AC, van Leerdam JA, de Voogta P (2009) Accurate mass screening and identification of emerging contaminants in environmental samples by liquid chromatography–hybrid linear ion trap Orbitrap mass spectrometry. J Chromatogr A 1216(3):510–519. doi:10.​1016/​j.​chroma.​2008.​08.​053 CrossRef
    Hu Q, Noll RJ, Hongyan L, Makarov A, Hardman M, Cooks RG (2005) The Orbitrap: a new mass spectrometer. J Mass Spectrom 40(4):430–443. doi:10.​1002/​jms.​856 CrossRef
    Hughey CA, Hendrickson CL, Rodgers RP, Marshall AG (2001) Elemental composition analysis of processed and unprocessed diesel fuel by electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry. Energy Fuels 15(5):1186–1193. doi:10.​1021/​ef010028b CrossRef
    Ibáñez M, Sancho JV, Pozo ÓJ, Hernández F, Niessen WMA (2005) Use of quadrupole time-of-flight mass spectrometry in the elucidation of unknown compounds present in environmental water. Rapid Commun Mass Spectrom 19(2):169–178. doi:10.​1002/​rcm.​1764 CrossRef
    Ibáñez M, Sancho JV, McMillan D, Rao R, Hernández F (2008) Rapid non-target screening of organic pollutants in water by ultra performance liquid chromatography coupled to time-of flight mass spectrometry. TrAC Trends Anal Chem 27(5):481–489. doi:10.​1016/​j.​trac.​2008.​03.​007 CrossRef
    Ibáñez M, Guerrero C, Sancho JV, Hernández F (2009) Screening of antibiotics in surface and wastewater samples by ultra-high-pressure liquid chromatography coupled to hybrid quadrupole time-of-flight mass spectrometry. J Chromatogr A 1216(12):2529–2539. doi:10.​1016/​j.​chroma.​2009.​01.​073 CrossRef
    Ibáñez M, Sancho JV, Pozo ÓJ, Hernández F (2011) Use of quadrupole time-of-flight mass spectrometry to determine proposed structures of transformation products of the herbicide bromacil after water chlorination. Rapid Commun Mass Spectrom 25:3103–3113. doi:10.​1002/​rcm.​5183 CrossRef
    Ibáñez M, Portolés T, Rúbies A, Muñoz E, Muñoz G, Pineda L, Serrahima E, Sancho JV, Centrich F, Hernández F (2012) The power of hyphenated chromatography/time-of-flight mass spectrometry in public health laboratories. J Agric Food Chem 60:5311–5323. doi:10.​1021/​jf300796d CrossRef
    Kaufmann A, Butcher P, Maden K, Walker S, Widmer M (2011) Semi-targeted residue screening in complex matrices with liquid chromatography coupled to high resolution mass spectrometry: current possibilities and limitations. Analyst 136(9):1898–1909. doi:10.​1039/​c0an00902d CrossRef
    Kellmann M, Muenster H, Zomer P, Mol H (2009) Full scan MS in comprehensive qualitative and quantitative residue analysis in food and feed matrices: how much resolving power is required? J Am Soc Mass Spectrom 20(8):1464–1476. doi:10.​1016/​j.​jasms.​2009.​05.​010 CrossRef
    Kern S, Fenner K, Singer HP, Schwarzenbach RP, Hollender J (2009) Identification of transformation products of organic contaminants in natural waters by computer-aided prediction and high-resolution mass spectrometry. Environ Sci Technol 43(18):7039–7046. doi:10.​1021/​es901979h CrossRef
    Kind T, Fiehn O (2006) Metabolomic database annotations via query of elemental compositions: mass accuracy is insufficient even at less than 1 ppm. BMC Bioinform. doi:10.​1186/​1471-2105-7-234234
    Kind T, Fiehn O (2007) Seven golden rules for heuristic filtering of molecular formulas obtained by accurate mass spectrometry. BMC Bioinform. doi:10.​1186/​1471-2105-8-105
    Kosjek T, Heath E, Petrovic M, Barceló D (2007) Mass spectrometry for identifying pharmaceutical biotransformation products in the environment. TrAC Trends Anal Chem 26(11):1076–1085. doi:10.​1016/​j.​trac.​2007.​10.​005 CrossRef
    Krauss M, Singer H, Hollender J (2010) LC–high resolution MS in environmental analysis: from target screening to the identification of unknowns. Anal Bioanal Chem 397(3):943–951. doi:10.​1007/​s00216-010-3608-9 CrossRef
    Li AC, Alton D, Bryant MS, Shou WZ (2005) Simultaneously quantifying parent drugs and screening for metabolites in plasma pharmacokinetic samples using selected reaction monitoring information-dependent acquisition on a QTrap instrument. Rapid Commun Mass Spectrom 19(14):1943–1950. doi:10.​1002/​rcm.​2008 CrossRef
    Li AC, Shou WZ, Mai TT, Jiang X (2007) Complete profiling and characterization of in vitro nefazodone metabolites using two different tandem mass spectrometric platforms. Rapid Commun Mass Spectrom 21(24):4001–4008. doi:10.​1002/​rcm.​3303 CrossRef
    Liao W, Draper WM, Perera SK (2008) Identification of unknowns in atmospheric pressure ionization mass spectrometry using a mass to structure search engine. Anal Chem 80(20):7765–7777. doi:10.​1021/​ac801166z CrossRef
    Lim H-K, Chen J, Sensenhauser C, Cook K, Subrahmanyam V (2007) Metabolite identification by data-dependent accurate mass spectrometric analysis at resolving power of 60,000 in external calibration mode using an LTQ/Orbitrap. Rapid Commun Mass Spectrom 21(12):1821–1832. doi:10.​1002/​rcm.​3024 CrossRef
    Makarov A, Denisov E, Kholomeev E, Balschun W, Lange O, Strupat K, Horning S (2006) Performance evaluation of a hybrid linear ion trap/orbitrap mass spectrometer. Anal Chem 78(7):2113–2120. doi:10.​1021/​ac0518811 CrossRef
    Mortishire-Smith RJ, O’Connor D, Castro-Perez J, Kirby J (2005) Accelerated throughput metabolic route screening in early drug discovery using high-resolution liquid chromatography/quadrupole time-of-flight mass spectrometry and automated data analysis. Rapid Commun Mass Spectrom 19(18):2659–2670. doi:10.​1002/​rcm.​2111 CrossRef
    Müller A, Schulz W, Ruck WKL, Weber WH (2011) A new approach to data evaluation in the non-target screening of organic trace substances in water analysis. Chemosphere 85(8):1211–1219. doi:10.​1016/​j.​chemosphere.​2011.​07.​009 CrossRef
    Nurmi J, Pellinen J (2011) Multiresidue method for the analysis of emerging contaminants in wastewater by ultra performance liquid chromatography-time-of-flight mass spectrometry. J Chromatogr A 1218:6712–6719. doi:10.​1016/​j.​chroma.​2011.​07.​071 CrossRef
    Nurmi J, Pellinen J, Rantalainen A-L (2012) Critical evaluation of screening techniques for emerging environmental contaminants based on accurate mass measurements with time-of-flight mass spectrometry. J Mass Spectrom 47(3):303–312. doi:10.​1002/​jms.​2964 CrossRef
    Ow SY, Noirel J, Salim M, Evans C, Watson R, Wright PC (2010) Balancing robust quantification and identification for iTRAQ: application of UHR-ToF MS. Proteomics 10(11):1–9. doi:10.​1002/​pmic.​200900746 CrossRef
    Pérez-Parada A, del Mar G-RM, Bueno MJM, Uclés S, Uclés A, Fernández-Alba AR (2012) Analytical improvements of hybrid LC-MS/MS techniques for the efficient evaluation of emerging contaminants in river waters: a case study of the Henares River (Madrid, Spain). Environ Sci Pollut Res 19(2):467–481. doi:10.​1007/​s11356-011-0585-2 CrossRef
    Perry RH, Cooks RG, Noll RJ (2008) Orbitrap mass spectrometry: instrumentation, ion motion and applications. Mass Spectrom Rev 27(6):661–699. doi:10.​1002/​mas.​20186 CrossRef
    Petrovic M, Barceló D (2006a) Liquid chromatography–mass spectrometry in the analysis of emerging environmental contaminants. Anal Bioanal Chem 385(3):422–424. doi:10.​1007/​s00216-006-0450-1 CrossRef
    Petrovic M, Barceló D (2006b) Application of liquid chromatography/quadrupole time-of-flight mass spectrometry (LC-QqTOF-MS) in the environmental analysis. J Mass Spectrom 41(10):1259–1267. doi:10.​1002/​jms.​1103 CrossRef
    Pitarc E, Portolés T, Marín JM, Ibáñez M, Albarrán F, Hernández F (2010) Analytical strategy based on the use of liquid chromatography and gas chromatography with triple-quadrupole and time-of-flight MS analyzers for investigating organic contaminants in wastewater. Anal Bioanal Chem 397:2763–2776. doi:10.​1007/​s00216-010-3692-x CrossRef
    Richardson S (2011) Water analysis: emerging contaminants and current issues. Anal Chem 83:4614–4648. doi:10.​1021/​ac200915r CrossRef
    Rousu T, Herttuainen J, Tolonen A (2010) Comparison of triple quadrupole, hybrid linear ion trap triple quadrupole, time-of-flight and LTQ-Orbitrap mass spectrometers in drug discovery phase metabolite screening and identification in vitro—amitriptyline and verapamil as model compounds. Rapid Commun Mass Spectrom 24(1):939–957. doi:10.​1002/​rcm.​4465 CrossRef
    Sancho JV, Pozo ÓJ, Ibáñez M, Hernández F (2006) Potential of liquid chromatography/time-of-flight mass spectrometry for the determination of pesticides and transformation products in water. Anal Bioanal Chem 386(4):987–997. doi:10.​1007/​s00216-006-0532-0 CrossRef
    Scripps Center for Metabolomics (2015) METLIN: Metabolite and Tandem MS Database, http://​metlin.​scripps.​edu/​ . Accessed Aug 2015
    Tiller PR, Yu S, Castro-Perez J, Fillgrove KL, Baillie TA (2008) High-throughput, accurate mass liquid chromatography/tandem mass spectrometry on a quadrupole time-of-flight system as a ‘first-line’ approach for metabolite identification studies. Rapid Commun Mass Spectrom 22(7):1053–1061. doi:10.​1002/​rcm.​3472 CrossRef
    Witt M, Fuchser J, Baykut G (2001) Fourier transform ion cyclotron resonance mass spectrometry with nano LC/micro electrospray ionization and matrix-assisted laser desorption/ionization: analytical performance in peptide mass fingerprint analysis. J Am Soc Mass Spectrom 1(6):553–561. doi:10.​1016/​S1044-0305(03)00138-7
    Wu J, Mc Allister H (2003) Exact mass measurement on an electrospray ionization time-of-flight mass spectrometer: error distribution and selective averaging. J Mass Spectrom 38(10):1043–1053. doi:10.​1002/​jms.​516 CrossRef
    Xia Y-Q, Miller JD, Bakhtiar R, Franklin RB, Liu DQ (2003) Use of a quadrupole linear ion trap mass spectrometer in metabolite identification and bioanalysis. Rapid Commun Mass Spectrom 17(11):1137–1145. doi:10.​1002/​rcm.​1037 CrossRef
    Yao M, Ma L, Duchoslav E, Zhu M (2009) Rapid screening and characterization of drug metabolites using multiple ion monitoring dependent product ion scan and post acquisition data mining on a hybrid triple quadrupole-linear ion trap mass spectrometer. Rapid Commun Mass Spectrom 23(11):1683–1693. doi:10.​1002/​rcm.​4045 CrossRef
    Zhu P, Ding W, Tong W, Ghosal W, Alton K, Chowdhury S (2009) A retention-time-shift-tolerant background subtraction and noise reduction algorithm (BgS-NoRA) for extraction of drug metabolites in liquid chromatography/mass spectrometry data from biological matrices. Rapid Commun Mass Spectrom 23(11):1563–1572. doi:10.​1002/​rcm.​4041 CrossRef
  • 作者单位:Fabio Gosetti (1)
    Eleonora Mazzucco (1)
    Maria Carla Gennaro (1)
    Emilio Marengo (1)

    1. Department of Science and Technological Innovation - DISIT, University of Piemonte Orientale, viale T. Michel 11, 15121, Alessandria, Italy
  • 刊物类别:Earth and Environmental Science
  • 刊物主题:Earth sciences
    Geochemistry
    Analytical Chemistry
    Biochemistry
    Monitoring, Environmental Analysis and Environmental Ecotoxicology
    Soil Science and Conservation
    Waste Water Technology, Water Pollution Control, Water Management and Aquatic Pollution
  • 出版者:Springer Berlin / Heidelberg
  • ISSN:1610-3661
文摘
Contamination of water resources is one of the major problems to be faced for environment preservation and sustainability. The monitoring of target compounds based on mass spectrometry and selected reaction monitoring mode is often insufficient to definitely assess the quality of surface water. Also potentially harmful non-target pollutants simultaneously present must be taken into account. Liquid chromatography coupled with tandem mass spectrometry is suitable to obtain complete information on water composition. Hybrid mass spectrometers such as triple quadrupole/linear ion trap, hybrid quadrupole/time-of-flight and linear ion trap/orbitrap analyzers should be used. Here, we review ultra-high performance liquid chromatography coupled with mass spectrometry methods developed for post-target and non-target screening analysis of water emerging contaminants, such as pesticides and their degradation products, pharmaceuticals and drug side-reaction products, surfactants and illicit drugs. The major points are the following: (1) the possibility of performing retrospective analysis only by high-resolution mass analyzer; (2) the compatibility of mass analyzer with ultra-high performance liquid chromatography; (3) the use of deconvolution software to detect unknowns; and (4) the limited availability of library database. Keywords UHPLC High-resolution mass spectrometry Non-target analysis Unknown compounds Emerging contaminants Surface water

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700