Quantification of left ventricular functional parameter values using 3D spiral bSSFP and through-time Non-Cartesian GRAPPA
详细信息    查看全文
  • 作者:Kestutis J Barkauskas ; Prabhakar Rajiah…
  • 关键词:Left ventricular functional CMR ; Spiral ; GRAPPA ; Non ; Cartesian ; Parallel imaging
  • 刊名:Journal of Cardiovascular Magnetic Resonance
  • 出版年:2014
  • 出版时间:December 2014
  • 年:2014
  • 卷:16
  • 期:1
  • 全文大小:2,433 KB
  • 参考文献:1. Patel, MR, White, RD, Abbara, S, Bluemke, DA, Herfkens, RJ, Picard, M, Shaw, LJ, Silver, M, Stillman, AE, Udelson, J (2013) ACCF/ACR/ASE/ASNC/SCCT/SCMR appropriate utilization of cardiovascular imaging in heart failure: a joint report of the American College of Radiology Appropriateness Criteria Committee and the American College of Cardiology Foundation Appropriate Use C. J Am Coll Cardiol 2013: pp. 2207-31 CrossRef
    2. Atkinson, DJ, Edelman, RR (1991) Cineangiography of the heart in a single breath hold with a segmented turboFLASH sequence. Radiology 178: pp. 357-60 CrossRef
    3. Scott, AD, Keegan, J, Firmin, DN (2009) Motion in cardiovascular MR. Radiology 250: pp. 331-351 CrossRef
    4. Pattynama, PM, Lamb, HJ, Velde, EA, Wall, EE, Roos, A (1993) Left ventricular measurements with cine and spin-echo MR imaging: a study of reproducibility with variance component analysis. Radiology 187: pp. 261-8 CrossRef
    5. Maroules, CD, McColl, R, Khera, A, Peshock, RM (2008) Interstudy reproducibility of SSFP cine magnetic resonance: impact of magnetic field strength and parallel imaging. J Magn Reson Imaging 27: pp. 1139-45 CrossRef
    6. Gandy, SJ, Waugh, SA, Nicholas, RS, Rajendra, N, Martin, P, Houston, JG (2008) MRI comparison of quantitative left ventricular structure, function and measurement reproducibility in patient cohorts with a range of clinically distinct cardiac conditions. Int J Cardiovasc Imaging 24: pp. 627-32 CrossRef
    7. Gay, SB, Sistrom, CL, Holder, CA, Suratt, PM (1994) Breath-holding capability of adults. Implications for spiral computed tomography, fast-acquisition magnetic resonance imaging, and angiography. Invest Radiol 29: pp. 848-51 CrossRef
    8. Marks, B, Mitchell, DG, Simelaro, JP (1997) Breath-holding in healthy and pulmonary-compromised populations: effects of hyperventilation and oxygen inspiration. J Magn Reson Imaging 7: pp. 595-597 CrossRef
    9. Mascarenhas, NB, Muthupillai, R, Cheong, B, Pereyra, M, Flamm, SD (2006) Fast 3D cine steady-state free precession imaging with sensitivity encoding for assessment of left ventricular function in a single breath-hold. AJR Am J Roentgenol 187: pp. 1235-9 CrossRef
    10. Makowski, MR, Wiethoff, AJ, Jansen, CHP, Uribe, S, Parish, V, Schuster, A, Botnar, RM, Bell, A, Kiesewetter, C, Razavi, R, Schaeffter, T, Greil, GF (2012) Single breath-hold assessment of cardiac function using an accelerated 3D single breath-hold acquisition technique–comparison of an intravascular and extravascular contrast agent. J Cardiovasc Magn Reson 14: pp. 53 CrossRef
    11. Kozerke, S, Tsao, J, Razavi, R, Boesiger, P (2004) Accelerating cardiac cine 3D imaging using k-t BLAST. Magn Reson Med 52: pp. 19-26 CrossRef
    12. Greil, GF, Germann, S, Kozerke, S, Baltes, C, Tsao, J, Urschitz, MS, Seeger, A, Tangcharoen, T, Bialkowsky, A, Miller, S, Sieverding, L (2008) Assessment of left ventricular volumes and mass with fast 3D cine steady-state free precession k-t space broad-use linear acquisition speed-up technique (k-t BLAST). J Magn Reson Imaging 27: pp. 510-5 CrossRef
    13. Nezafat, R, Herzka, D, Stehning, C, Peters, DC, Nehrke, K, Manning, WJ (2008) Inflow quantification in three-dimensional cardiovascular MR imaging. J Magn Reson Imaging 28: pp. 1273-9 CrossRef
    14. Huber, S, Muthupillai, R, Mojibian, H, Cheong, B, Kouwenhoven, M, Flamm, SD (2008) Rapid assessment of regional and global l
  • 刊物主题:Imaging / Radiology; Angiology; Cardiology;
  • 出版者:BioMed Central
  • ISSN:1532-429X
文摘
Background The standard clinical acquisition for left ventricular functional parameter analysis with cardiovascular magnetic resonance (CMR) uses a multi-breathhold multi-slice segmented balanced SSFP sequence. Performing multiple long breathholds in quick succession for ventricular coverage in the short-axis orientation can lead to fatigue and is challenging in patients with severe cardiac or respiratory disorders. This study combines the encoding efficiency of a six-fold undersampled 3D stack of spirals balanced SSFP sequence with 3D through-time spiral GRAPPA parallel imaging reconstruction. This 3D spiral method requires only one breathhold to collect the dynamic data. Methods Ten healthy volunteers were recruited for imaging at 3?T. The 3D spiral technique was compared against 2D imaging in terms of systolic left ventricular functional parameter values (Bland-Altman plots), total scan time (Welch’s t-test) and qualitative image rating scores (Wilcoxon signed-rank test). Results Systolic left ventricular functional values were not significantly different (i.e. 3D-2D) between the methods. The 95% confidence interval for ejection fraction was ?.1?±-.6% (mean?±-.96*SD). The total scan time for the 3D spiral technique was 48?s, which included one breathhold with an average duration of 14?s for the dynamic scan, plus 34?s to collect the calibration data under free-breathing conditions. The 2D method required an average of 5min40s for the same coverage of the left ventricle. The difference between 3D and 2D image rating scores was significantly different from zero (Wilcoxon signed-rank test, p--.05); however, the scores were at least 3 (i.e. average) or higher for 3D spiral imaging. Conclusion The 3D through-time spiral GRAPPA method demonstrated equivalent systolic left ventricular functional parameter values, required significantly less total scan time and yielded acceptable image quality with respect to the 2D segmented multi-breathhold standard in this study. Moreover, the 3D spiral technique used just one breathhold for dynamic imaging, which is anticipated to reduce patient fatigue as part of the complete cardiac examination in future studies that include patients.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700