K-t GRAPPA-accelerated 4D flow MRI of liver hemodynamics: influence of different acceleration factors on qualitative and quantitative assessment of blood flow
详细信息    查看全文
  • 作者:Zoran Stankovic ; Jury Fink…
  • 关键词:4D flow MRI ; Liver hemodynamics ; k ; t GRAPPA ; Quantification ; Wall shear stress
  • 刊名:Magnetic Resonance Materials in Physics, Biology and Medicine
  • 出版年:2015
  • 出版时间:April 2015
  • 年:2015
  • 卷:28
  • 期:2
  • 页码:149-159
  • 全文大小:912 KB
  • 参考文献:1. Bell, BP, Manos, MM, Zaman, A, Terrault, N, Thomas, A, Navarro, VJ, Dhotre, KB, Murphy, RC, Ness, GR, Stabach, N, Robert, ME, Bower, WA, Bialek, SR, Sofair, AN (2008) The epidemiology of newly diagnosed chronic liver disease in gastroenterology practices in the United States: results from population-based surveillance. Am J Gastroenterol 103: pp. 2727-2736 CrossRef
    2. Groszmann, RJ (1994) Hyperdynamic circulation of liver disease 40?years later: pathophysiology and clinical consequences. Hepatology 20: pp. 1359-1363 CrossRef
    3. Berzigotti, A, Seijo, S, Reverter, E, Bosch, J (2013) Assessing portal hypertension in liver diseases. Expert Rev Gastroenterol Hepatol 7: pp. 141-155 CrossRef
    4. Bintintan, A, Chira, RI, Mircea, PA (2013) Non-invasive ultrasound-based diagnosis and staging of esophageal varices in liver cirrhosis. A systematic review of the literature published in the third millenium. Med Ultrason 15: pp. 116-124 CrossRef
    5. Malek, AM, Jackman, R, Rosenberg, RD, Izumo, S (1994) Endothelial expression of thrombomodulin is reversibly regulated by fluid shear stress. Circ Res 74: pp. 852-860 CrossRef
    6. Lehoux, S, Tedgui, A (2003) Cellular mechanics and gene expression in blood vessels. J Biomech 36: pp. 631-643 CrossRef
    7. Truong, U, Fonseca, B, Dunning, J, Burgett, S, Lanning, C, Ivy, DD, Shandas, R, Hunter, K, Barker, AJ (2013) Wall shear stress measured by phase contrast cardiovascular magnetic resonance in children and adolescents with pulmonary arterial hypertension. J Cardiovasc Magn Reson 15: pp. 81 CrossRef
    8. Lorenz, R, Bock, J, Barker, AJ, Knobelsdorff-Brenkenhoff, F, Wallis, W, Korvink, JG, Bissell, MM, Schulz-Menger, J, Markl, M (2014) 4D flow magnetic resonance imaging in bicuspid aortic valve disease demonstrates altered distribution of aortic blood flow helicity. Magn Reson Med 71: pp. 1542-1553 CrossRef
    9. Markl, M, Frydrychowicz, A, Kozerke, S, Hope, M, Wieben, O (2012) 4D flow MRI. J Magn Reson Imaging 36: pp. 1015-1036 CrossRef
    10. Stankovic, Z, Allen, BD, Garcia, J, Jarvis, KB, Markl, M (2014) 4D flow imaging with MRI. Cardiovasc Diagn Ther 4: pp. 173-192
    11. Wentland, AL, Grist, TM, Wieben, O (2013) Repeatability and internal consistency of abdominal 2D and 4D phase contrast MR flow measurements. Acad Radiol 20: pp. 699-704 CrossRef
    12. Stankovic, Z, Frydrychowicz, A, Csatari, Z, Panther, E, Deibert, P, Euringer, W, Kreisel, W, Russe, M, Bauer, S, Langer, M, Markl, M (2010) MR-based visualization and quantification of three-dimensional flow characteristics in the portal venous system. J Magn Reson Imaging 32: pp. 466-475 CrossRef
    13. Frydrychowicz, A, Landgraf, BR, Niespodzany, E, Verma, RW, Roldan-Alzate, A, Johnson, KM, Wieben, O, Reeder, SB (2011) Four-dimensional velocity mapping of the hepatic and splanchnic vasculature with radial sampling at 3 tesla: a feasibility study in portal hypertension. J Magn Reson Imaging 34: pp. 577-584 CrossRef
    14. Stankovic, Z, Csatari, Z, Deibert, P, Euringer, W, Blanke, P, Kreisel, W, Abdullah Zadeh, Z, Kallfass, F, Langer, M, Markl, M (2012) Normal and altered three-dimensional portal venous hemodynamics in patients with liver cirrhosis. Radiology 262: pp. 862-873 CrossRef
    15. Roldan-Alzate, A, Frydrychowicz, A, Niespodzany, E, Landgraf, BR, Johnson, KM, Wieben, O, Reeder, SB (2013) In vivo validation of 4D flow MRI for assessing the hemodyn
  • 刊物主题:Imaging / Radiology; Computer Appl. in Life Sciences; Solid State Physics; Biomedical Engineering; Health Informatics;
  • 出版者:Springer Berlin Heidelberg
  • ISSN:1352-8661
文摘
Objective We sought to evaluate the feasibility of k-t parallel imaging for accelerated 4D flow MRI in the hepatic vascular system by investigating the impact of different acceleration factors. Materials and methods k-t GRAPPA accelerated 4D flow MRI of the liver vasculature was evaluated in 16 healthy volunteers at 3T with acceleration factors R?=?3, R?=?5, and R?=?8 (2.0?×?2.5?×?2.4?mm3, TR?=?82?ms), and R?=?5 (TR?=?41?ms); GRAPPA R?=?2 was used as the reference standard. Qualitative flow analysis included grading of 3D streamlines and time-resolved particle traces. Quantitative evaluation assessed velocities, net flow, and wall shear stress (WSS). Results Significant scan time savings were realized for all acceleration factors compared to standard GRAPPA R?=?2 (21-1?%) (p?R?=?3 and R?=?5 compared to standard GRAPPA R?=?2. Significantly increased leakage artifacts and noise were seen between standard GRAPPA R?=?2 and k-t GRAPPA R?=?8 (p?p?R?=?5, while significantly higher values were observed for the same acceleration with higher temporal resolution in two veins (p? Conclusion k-t acceleration of 4D flow MRI is feasible for liver hemodynamic assessment with acceleration factors R?=?3 and R?=?5 resulting in a scan time reduction of at least 40?% with similar quantitation of liver hemodynamics compared with GRAPPA R?=?2.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700