Shortened breath-hold contrast-enhanced MRI of the liver using a new parallel imaging technique, CAIPIRINHA (controlled aliasing in parallel imaging results in higher acceleration): a comparison with conventional GRAPPA technique
详细信息    查看全文
  • 作者:Masaki Ogawa ; Tatsuya Kawai ; Hirohito Kan ; Susumu Kobayashi…
  • 关键词:Controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) ; Short breath hold ; 3 ; Dimensional volumetric interpolated breath ; hold examination (3D ; VIBE) ; Parallel imaging technique ; High acceleration factor (AF) ; Gadoxetic acid ; enhanced liver MRI
  • 刊名:Abdominal Imaging
  • 出版年:2015
  • 出版时间:October 2015
  • 年:2015
  • 卷:40
  • 期:8
  • 页码:3091-3098
  • 全文大小:803 KB
  • 参考文献:1.Lee VS, Lavelle MT, et al. (2000) Hepatic MR imaging with a dynamic contrast-enhanced isotropic volumetric interpolated breath-hold examination: feasibility, reproducibility, and technical quality. Radiology 215(2):365鈥?72. doi:10.鈥?148/鈥媟adiology.鈥?15.鈥?.鈥媟00ma16365 CrossRef PubMed
    2.Riffel P, Attenberger UI, Kannengiesser S, et al. (2013) Highly accelerated T1-weighted abdominal imaging using 2-dimensional controlled aliasing in parallel imaging results in higher acceleration: a comparison with generalized autocalibrating partially parallel acquisitions parallel imaging. Invest Radiol 48(7):554鈥?61. doi:10.鈥?097/鈥婻LI.鈥?b013e31828654ff鈥?/span> CrossRef PubMed
    3.Yoon JH, Lee JM, Yu MH, et al. (2014) High-resolution T1-weighted gradient echo imaging for liver MRI using parallel imaging at high-acceleration factors. Abdom Imaging 39(4):711鈥?21. doi:10.鈥?007/鈥媠00261-014-0099-8 CrossRef PubMed
    4.Yu MH, Lee JM, Yoon JH, et al. (2013) Clinical application of controlled aliasing in parallel imaging results in a higher acceleration (CAIPIRINHA)-volumetric interpolated breathhold (VIBE) sequence for gadoxetic acid-enhanced liver MR imaging. J Magn Reson Imaging 38(5):1020鈥?026. doi:10.鈥?002/鈥媕mri.鈥?4088 CrossRef PubMed
    5.Zech CJ, Herrmann KA, Reiser MF, Schoenberg SO (2007) MR imaging in patients with suspected liver metastases: value of liver-specific contrast agent Gd-EOB-DTPA. Magn Reson Med Sci 6(1):43鈥?2.CrossRef PubMed
    6.Akai H, Kiryu S, Matsuda I, et al. (2011) Detection of hepatocellular carcinoma by Gd-EOB-DTPA-enhanced liver MRI: comparison with triple phase 64 detector row helical CT. Eur J Radiol 80(2):310鈥?15. doi:10.鈥?016/鈥媕.鈥媏jrad.鈥?010.鈥?7.鈥?26 CrossRef PubMed
    7.Muhi A, Ichikawa T, Motosugi U, et al. (2011) Diagnosis of colorectal hepatic metastases: comparison of contrast-enhanced CT, contrast-enhanced US, superparamagnetic iron oxide-enhanced MRI, and gadoxetic acid-enhanced MRI. J Magn Reson Imaging 34(2):326鈥?35. doi:10.鈥?002/鈥媕mri.鈥?2613 CrossRef PubMed
    8.Wright KL, Harrell MW, Jesberger JA, et al. (2014) Clinical evaluation of CAIPIRINHA: comparison against a GRAPPA standard. J Magn Reson Imaging 39(1):189鈥?94. doi:10.鈥?002/鈥媕mri.鈥?4105 CrossRef PubMed
    9.Pruessmann KP, Weiger M, Scheidegger MB, Boesiger P (1999) SENSE: sensitivity encoding for fast MRI. Magn Reson Med 42(5):952鈥?62. doi:10.鈥?002/鈥?SICI)1522-2594 CrossRef PubMed
    10.Glockner JF, Hu HH, Stanley DW, Angelos L, King K (2005) Parallel MR imaging: a user鈥檚 guide. Radiographics 25(5):1279鈥?297. doi:10.鈥?148/鈥媟g.鈥?55045202 CrossRef PubMed
    11.Vogt FM, Antoch G, Hunold P, et al. (2005) Parallel acquisition techniques for accelerated volumetric interpolated breath-hold examination magnetic resonance imaging of the upper abdomen: assessment of image quality and lesion conspicuity. J Magn Reson Imaging 21(4):376鈥?82. doi:10.鈥?002/鈥媕mri.鈥?0288 CrossRef PubMed
    12.Yutzy SR, Seiberlich N, Duerk JL, Griswold MA (2011) Improvements in multislice parallel imaging using radial CAIPIRINHA. Magn Reson Med 65(6):1630鈥?637. doi:10.鈥?002/鈥媘rm.鈥?2752 PubMedCentral CrossRef PubMed
    13.Park YS, Lee CH, Kim IS, et al. (2014) Usefulness of controlled aliasing in parallel imaging results in higher acceleration in gadoxetic acid-enhanced liver magnetic resonance imaging to clarify the hepatic arterial phase. Invest Radiol 49(3):183鈥?88. doi:10.鈥?097/鈥婻LI.鈥?000000000000011鈥?/span> CrossRef PubMed
    14.Breuer FA, Blaimer M, Heidemann RM, et al. (2005) Controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) for multi-slice imaging. Magn Reson Med 53(3):684鈥?91. doi:10.鈥?002/鈥媘rm.鈥?0401 CrossRef PubMed
    15.Morani AC, Vicens RA, Wei W, et al. (2015) CAIPIRINHA-VIBE and GRAPPA-VIBE for liver MRI at 1.5 T: a comparative in vivo patient study. J Comput Assist Tomogr 39(2):263鈥?69. doi:10.鈥?097/鈥婻CT.鈥?000000000000200鈥?/span> CrossRef PubMed
    16.Motulsky H (1997) Appropriate simple size. In: Motulsky H (ed) trans Intuitive biostatics. Tokyo: Science Medical, pp 196鈥?05
    17.Kitoh Y, Imai H, Miyati T, et al. (2012) Effects of region of interest settings in signal-to-noise ratio measurement of clinical images using arrays of multiple receiver coils. Nihon Hoshasen Gijutsu Gakkai Zasshi 68(9):1269鈥?278CrossRef PubMed
    18.Dietrich O, Raya JG, Reeder SB, Reiser MF, Schoenberg SO (2007) Measurement of signal-to-noise ratios in MR images: influence of multichannel coils, parallel imaging, and reconstruction filters. J Magn Reson Imaging 26(2):375鈥?85. doi:10.鈥?002/鈥媕mri.鈥?0969 CrossRef PubMed
    19.Tanimoto A, Higuchi N, Ueno A (2012) Reduction of ringing artifacts in the arterial phase of gadoxetic acid-enhanced dynamic MR imaging. Magn Reson Med Sci 11(2):91鈥?7CrossRef PubMed
  • 作者单位:Masaki Ogawa (1)
    Tatsuya Kawai (1)
    Hirohito Kan (1)
    Susumu Kobayashi (2)
    Yoshihiro Akagawa (2)
    Kazushi Suzuki (1)
    Shunsuke Nojiri (3)
    Yoshiyuki Ozawa (1)
    Yuta Shibamoto (1)

    1. Department of Radiology, Nagoya City University Graduate School of Medical Sciences, 1, Kawasumi, Mizuho-cho, Mizuho-ku, Nagoya, 467-8601, Japan
    2. Department of Radiology, Toyokawa City Hospital, Toyokawa, Japan
    3. Department of Gastroenterology and Metabolism, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan
  • 刊物类别:Medicine
  • 刊物主题:Medicine & Public Health
    Imaging and Radiology
    Gastroenterology
    Hepatology
  • 出版者:Springer New York
  • ISSN:1432-0509
文摘
Purpose We examined whether the shortened breath-hold 3-dimensional volumetric interpolated breath-hold examination (3D-VIBE) sequence for high acceleration factor (AF) using the controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) could substitute for the conventional sequence using generalized autocalibrating partially parallel acquisition (GRAPPA) in patients undergoing routine gadoxetic acid-enhanced liver MRI.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700