Comparison of digitally reconstructed radiographs generated from axial and helical CT scanning modes: a phantom study
详细信息    查看全文
  • 作者:Vinod Nelson (1)
    Shrikant Deshpande (1) (2)
    Alison Gray (1)
    Phillip Vial (1) (3)
    Lois Holloway (1) (2) (3)
  • 关键词:Digitally reconstructed radiographs ; Modulation transfer function ; CT simulation phantom ; Helical CT
  • 刊名:Australasian Physical & Engineering Sciences in Medicine
  • 出版年:2014
  • 出版时间:June 2014
  • 年:2014
  • 卷:37
  • 期:2
  • 页码:285-290
  • 全文大小:
  • 参考文献:1. Baker GR (2006) Localization: conventional and CT simulation. Br J Radiol 79:S36–S49 CrossRef
    2. Mutic S, Palta JR, Butker EK et al (2003) Quality assurance of computed-tomography simulators and the computed tomography simulation process: report of the AAPM Radiation Therapy Committee Task Group No. 66. Med Phys 30(10):2762-792 CrossRef
    3. McGee KP, Das IJ, Sims C (1995) Evaluation of digitally reconstructed radiographs (DRRs) used for clinical radiotherapy: a phantom study. Med Phys 22(11):1815-827 CrossRef
    4. Rathee S, Fallone BG, Robinson D (2002) Modulation transfer function of digitally reconstructed radiographs using helical computed tomography. Med Phys 29(1):86-9 CrossRef
    5. Primak AN, McCollough CH, Bruesewitz MR, Zhang J, Fletcher JG (2006) Relationship between noise, dose, and pitch in cardiac multi-detector row CT. Radiographics 26(6):1785-794 CrossRef
    6. McDermott A, White AR, Mc-Nitt-Gray M (2009) Pediatric organ dose measurements in axial and helical multislice CT. Med Phys 36(5):1494-499 CrossRef
    7. Pitman AG, Budd RS, McKenzie AF (1997) Radiation dose in computed tomography of the pelvis: comparison of helical and axial scanning. Australas Radiol 41(4):329-35 CrossRef
    8. Lakits A, Prokesch R, Scholda C, Nowotny R, Kaider A, Bankier A (2000) Helical and conventional CT in the imaging of metallic foreign bodies in the orbit. Acta Ophthalmol Scand 78(1):79-3 CrossRef
    9. Yen SY, Rubin GD, Napel S (1999) Spatially varying longitudinal aliasing and resolution in computed tomography. Med Phys 26(12):2617-625 CrossRef
    10. Kirwin SL, Langmack KA (2005) Determination of the modulation transfer function of digitally reconstructed radiographs in radiotherapy treatment planning using a point phantom. Phys Med Biol 50:N251–N255 CrossRef
    11. Mayles P, Nahum AE, Rosenwald J-C (2002) Handbook of radiotherapy physics: theory and practice. CRC Press, Bristol, pp 677-79
    12. Moseley DJ, White EA, Wiltshire KL et al (2007) Comparison of localization performance with implanted fiducial markers and cone-beam computed tomography for online image-guided radiotherapy of prostate. Int J Radiat Oncol Biol Phys 67(3):942-53 CrossRef
    13. Operators manual: CT simulation phantom model 76-417 (2007) Fluke Biomedical, Radiation Management Services, Cleveland
    14. XiO User’s Manual, V 4.40 (2009) Digitally reconstructed radiographs—technical considerations
    15. Droege RT, Morin RL (1982) A practical method to measure the MTF of CT scanners. Med Phys 9(5):758-60 CrossRef
    16. De Hauwere A, Bacher K, Smeets P, Verstraete K, Thierens H (2005) Analysis of image quality in digital chest imaging. Radiat Prot Dosim 117(1-):174-77
    17. Sung-Woo L, Jian-Yue J, Huaiqun G, Flavious M, Jae Ho K, Fang-Fang Y (2008) Clinical assessment and characterization of a dual-tube kilovoltage X-ray localization system in the radiotherapy treatment room. J Appl Clin Med Phys 9(1):1-5
    18. Hui H (1999) Multislice helical CT: scan and reconstruction. Med Phys 26(1):5-7 CrossRef
    19. Tanaka C, Ueguchi T, Shimosegawa E, Sasaki N, Johkoh T, Nakamura H, Hatazawa J (2006) Effect of CT acquisition parameters in the detection of subtle hypoattenuation in acute cerebral infarction: a phantom study. Am J Neuroradiol 27:40-5
    20. Apfaltrer P, Hanna EL, Schoepf UJ, Spears JR, Schoenberg SO, Fink C, Vliegenthart R (2012) Radiation dose and image quality at high pitch CT angiography of the aorta:intraindividual and interindividual comparisons with conventional CT angiograpy. Am J Roentgenol 199:1402-409 CrossRef
    21. Niu YT, Olszewski ME, Zhang YX, Liu YF, Xian JF, Wang ZC (2011) Experimental study and optimization of scan parameters that influence radiation dose in temporal bone high-resolution multidetector row CT. Am J Neuroradiol 32:1783-788 CrossRef
  • 作者单位:Vinod Nelson (1)
    Shrikant Deshpande (1) (2)
    Alison Gray (1)
    Phillip Vial (1) (3)
    Lois Holloway (1) (2) (3)

    1. Department of Medical Physics, Liverpool & Macarthur Cancer Therapy Centres, Campbelltown Hospital, PO Box 149, Campbelltown, NSW, 2560, Australia
    2. Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW, 2522, Australia
    3. Institute of Medical Physics, School of Physics, University of Sydney, Camperdown, NSW, 2050, Australia
  • ISSN:1879-5447
文摘
Digitally reconstructed radiographs (DRRs) play a vital role for verifying patient position for many radiotherapy treatments. As DRRs are generated from CT scans, image quality may be affected by the scanning mode (axial or helical). The aim of this study was to investigate the high and low contrast resolution and the spatial linearity in DRRs as a function of CT scanning mode and to highlight the significance of this variation, if any. A commercial CT phantom (Fluke Biomedical Model 76-417) was scanned with a Siemens Somatom Sensation 4 CT scanner using six variations of field of view, scanning mode and helical pitch. The image quality of the DRR’s produced from the scans was evaluated in terms of high contrast resolution using the modulation transfer function, low contrast resolution using Image Quality Score method and spatial linearity. The results indicated that the high contrast resolution for the axial mode was comparable to that for the helical modes. The low contrast resolution with axial scanning was comparable to scans performed with a helical pitch of 1 but deteriorated at pitches greater than 1. The field of view was not found to impact the low contrast resolution. When changing scanning parameters the impact on DRR quality should be considered. For DRRs, particularly where visualisation of low contrast structures is desired, a helical scan with a pitch of 1 is recommended.