参考文献:1. H. R. Zare, N. Rajabzadeh, N. Nasirizadeh, and M. M. Ardakani, J. Electroanal. Chem., 589, 60 (2006). 2. J. A. Drisko, J. Chapman, and V. J. Hunter, J. Am. Coll. Nutr., 22, 118 (2003). 3. R. D. Blakely, Science, 293, 2407 (2001). 4. F. M. Benes, Trends Pharmacol. Sci., 22, 46 (2001). 5. K. Anderson, A. Kuruvilla, N. Uretsky, and D. D. Miller, J. Med. Chem., 24, 683 (1981). 6. Z. Gao and H. Huang, Chem. Commun., 2107 (1998). 7. M. A. Dayton and A. G. Ewing, R. M. Wightman, Anal. Chem., 52, 2392 (1980). 8. C. R. Raj, K. Tokuda, and T. Ohsaka, Bioelectrochemistry, 53, 183–191 (2001). 9. G. P. Jin, X. Q. Lin, and J. M. Gong, J. Electroanal. Chem., 69, 135–142 (2004). 10. G. Y. Jin, Y. Z. Zhang, and W. X. Cheng, Sens. Actuat. B: Chem., 107, 528–534 (2005). 11. A. Domenech, H. Garcia, M. T. Domenech-Carbo, and M. S. Galletero, Anal. Chem., 74, 562 (2002). 12. F. Bosch-Reig and P. Campins-Falco, Analyst, 113, 1011–1016 (1988). 13. F. Bosch-Reig, P. Campins-Falco, and J. Verdu-Andres, Anal. Chim. Acta, 283, 831–844 (1993). 14. F. Bosch-Reig, P. Campins-Falco, A. Sevillano-Cabeza, R. Herraez-Hernandez, and C. Molins-Legua, Anal. Chem., 63, 2424–2429 (1991). 15. J. Yang, G. Zhou, N. Jie, R. Han, C. Lin, and J. Hu, Anal. Chim. Acta, 325, 195–200 (1996). 16. P. Campins-Falco, J. Verdu-Andres, and F. Bosch-Reig, Anal. Chim. Acta, 348, 39–49 (1997). 17. P. Campins-Falco, F. Bosch-Reig, and F. Blasco-Gomez, Talanta, 47, 193–202 (1998). 18. J. Verdu-Andres, F. Bosch-Reig, and P. Campins-Falco, J. Chemom., 12, 27–40 (1998). 19. A. Safavi, H. Abdollahi, F. Sedaghatpour, and S. Zeinali, Anal. Chim. Acta, 409, 275–282 (2000). 20. A. Safavi and H. Abdollahi, Talanta, 54, 727–734 (2001). 21. A. Safavi, H. Abdollahi, and M. R. Hormozi Nezhad, Talanta, 56, 699–704 (2002). 22. A. Safavi, H. Abdollahi, and M. Bagheri, Anal. Chim. Acta, 459, 119–131 (2002). 23. A. Safavi, H. Abdollahi, F. Sedaghatpour, and M.R. Hormozi Nezhad, Talanta, 59, 147–153 (2003). 24. H. Abdollahi and S. Zeinali, Talanta, 62, 151–163 (2004). 25. A. Safavi and O. Moradlou, Anal. Lett., 37, 2337–2349 (2004). 26. A. Safavi, F. Towhidi, and H. Abdollahi, Can. J. Anal. Sci. Spectrosc., 49, 309–313 (2004). 27. T. C. O’Haver, Anal. Proc., 19, 22 (1982). 28. Nian Bing Li, Wang Ren, and Hong Qun Luo, J. Sol. St. Electrochem., 12, 693–699 (2008). 29. Zl. D. Peterson, D. C. Collins, C. R. Bowerbank, M. L. Lee, and S. W. Graves, J. Chromatogr. B, 776, 221–229 (2002). 30. Quanmin Li, Juan Li, and Zhanjun Yang, Anal. Chim. Acta, 583, 147–152 (2007). 31. Faten A. Nour El-Dien, Eman Y. A. Frag, and Gehad G. Mohamed, Drug Test. Anal., 2, 234–242 (2010). 32. Masoud Rohani Moghadam, Shayessteh Dadfarnia, Ali Mohammad Haji Shabani, and Parviz Shahbazikhah, Anal. Biochem., 410, 289–295 (2011).
A highly sensitive H-point standard addition method (HPSAM) was investigated for identification of dopamine and ascorbic acid in some synthetic and pharmaceutical samples in an aqueous medium at pH 9.2 using a universal buffer. The most suitable wavelengths for dopamine and ascorbic acid detection are 260:271 nm and 248:270 nm respectively. Recovery values are between 99.0–101 %. Also, the effect of most common interferents was studied. Detection ranges for dopamine and ascorbic acid are 2·10–6–5·10–5 M and 6·10–6–3·10–5 M respectively with an RSD range between 1.3 and 2.0 %. The method was used to determine both reagents in real and synthesized samples.