First Indonesian proficiency testing scheme using reference values for cadmium, copper, and iron in drinking water
详细信息    查看全文
  • 作者:Rosi Ketrin ; Eka Mardika Handayani ; Isna Komalasari…
  • 关键词:Proficiency testing ; Reference value ; Drinking water ; Candidate reference material ; z ; Score
  • 刊名:Accreditation and Quality Assurance: Journal for Quality, Comparability and Reliability in Chemical Measurement
  • 出版年:2015
  • 出版时间:August 2015
  • 年:2015
  • 卷:20
  • 期:4
  • 页码:281-285
  • 全文大小:239 KB
  • 参考文献:1.UNE-EN ISO/IEC 17025 (2005) General requirements for the competence of testing and calibration laboratories. International Organization for Standardization, Geneva
    2.Nielsen HS (2003) Silver hazards to fish, wildlife and invertebrates: a synoptic review, contaminant hazard reviews report (biological report 32, September 1996). Wildlife Research Center U.S. National Biological Service, Patuxent
    3.Heydorn K (2006) Accred Qual Assur 10:479-84View Article
    4.Rienitz O, Sch iel D, Guttler B, Koch M, Borchers U (2007) Accred Qual Assur 12:615-22View Article
    5.Detaille R, Maetz P (2006) Accred Qual Assur 11:408-13View Article
    6.ISO 13528 (2005) Statistical methods for use in proficiency testing by interlaboratory comparisons. International Organization for Standardization, Geneva
    7.Horwitz W, Kamps LR, Boyer KW (1980) J Assoc off Anal Chem 1344:63-8
    8.ISO Guide 35 (2006) Reference materials—general and statistical principles for certification. International Organization for Standardization, Geneva
    9. http://?www.?quodata.?de/?en/?software/?for-interlaboratory-tests/?software-for-interlaboratory-studies-prolab.?html
    10.Walker R, Lumley I (1999) TrAC 18:594-16
    11.ISO (1995) Guide to the expression of uncertainty measurement. GUM, International Organization for Standardization, Geneva
    12.Baldan A, van der Veen AMH, Prause D, Recknagel A, Boley N, Evans S, Woods D (2001) Accred Qual Assur 6:164-67View Article
  • 作者单位:Rosi Ketrin (1)
    Eka Mardika Handayani (1)
    Isna Komalasari (1)
    Christine Elishian (1)

    1. Research Center for Chemistry, Indonesian Institute of Sciences (RCChem-LIPI), Kawasan PUSPIPTEK, Serpong, Indonesia
  • 刊物类别:Chemistry and Materials Science
  • 刊物主题:Chemistry
    Analytical Chemistry
    Food Science
    Biochemistry
    Commercial Law
    Monitoring, Environmental Analysis and Environmental Ecotoxicology
    Marketing
  • 出版者:Springer Berlin / Heidelberg
  • ISSN:1432-0517
文摘
Proficiency testing (PT) performance evaluation based on a consensus value for the assigned value is commonly used because it is considered cheap and thus easily approachable, and also gives a good confidence to the PT participants, since their results contribute to the establishment of the assigned value. However, the consensus value has a weakness in that it could be significantly different from the true value due to largely inexperienced laboratories participating in the PT scheme. Starting from 2013, the Research Center for Chemistry, Indonesian Institute of Sciences, tried to conduct a PT scheme using reference values for cadmium, copper, and iron in drinking water samples in order to increase the reliability of measurement results from Indonesian testing laboratories. The PT sample is a candidate reference material with reference values which were calculated from the measurement results using two comparable methods of inductively coupled plasma optical emission spectrometry and graphite furnace atomic absorption spectrometry. Data evaluation of the PT results was based on ISO 13528 and calculated with the z-score statistic method using PROLAB software. Sixty-two laboratories from the whole Indonesian region participated, and about 94?% and 71?% showed good performance for copper and iron, respectively, since the values were above the quantification limit, and the mean of the result was close to the reference values. However, there was a big difference between the mean and the reference value for cadmium due to the lack of knowledge and experience of most laboratories in Indonesia to measure the trace concentrations of elements such as cadmium. The results of the participants all together were so poor, that the use of consensus value would have been of less quality than the reference value. Therefore, the only way to evaluate cadmium in this PT scheme was by using the reference value.