Analytical performance of glucometers in a tertiary care hospital
详细信息    查看全文
  • 作者:Angela Somavilla Higioka…
  • 关键词:Point ; of ; care tests ; Capillary glucose ; Glucometer ; Accuracy assessment
  • 刊名:Accreditation and Quality Assurance: Journal for Quality, Comparability and Reliability in Chemical Measurement
  • 出版年:2016
  • 出版时间:April 2016
  • 年:2016
  • 卷:21
  • 期:2
  • 页码:143-149
  • 全文大小:384 KB
  • 参考文献:1.Umpierrez GE, Hellman R, Korytkowski MT, Kosiborod M, Maynard GA, Montori VM, Seley JJ, Van den Berghe G (2012) Management of hyperglycemia in hospitalized patients in non-critical care setting: an endocrine society clinical practice guideline. J Clin Endocrinol Metab 97:16–38CrossRef
    2.Moghissi ES, Korytkowski MT, DiNardo M, Einhorn D, Hellman R, Hirsch IB, Inzucchi SE, Ismail-Beigi F, Kirkman MS, Umpierrez GE (2009) American Association of Clinical Endocrinologists and American Diabetes Association consensus statement on inpatient glycemic control. Diabetes Care 32:1119–1131CrossRef
    3.Murad MH, Coburn JA, Coto-Yglesias F, Dzyubak S, Hazem A, Lane MA, Prokop LJ, Montori VM (2012) Glycemic control in non-critically ill hospitalized patients: a systematic review and meta-analysis. J Clin Endocrinol Metab 97:49–58CrossRef
    4.Lode PV (2005) Point-of-care immunotesting approaching the analytical performance of Central Laboratory methods. Clin Biochem 38:591–606CrossRef
    5.American Diabetes Association (ADA) (2013) Standards of medical care in diabetes 2013 (position statement). Diabetes Care 36:11–66CrossRef
    6.Nichols JH (2006) Quality in point-of-care testing: taking POC to the next level. Accred Qual Assur 11:273–277CrossRef
    7.Plebani M (2006) Laboratory network of excellence: enhancing patient safety and service effectiveness. Clin Chem Lab Med 44:150–156
    8.ANVISA. RDC No. 302, de 13 de outubro de 2005 (2005) Dispõe sobre o Regulamento Técnico para funcionamento de Laboratórios Clínicos. Ministério da Saúde, Brasília
    9.Wang J (2008) Electrochemical glucose biosensors. Chem Rev 108:814–825CrossRef
    10.ISO 15197 (2013) In vitro diagnostic test systems—requirements for blood-glucose monitoring systems for self-testing in managing diabetes mellitus. International Organization for Standardization. Geneva, Switzerland
    11.Clinical and Laboratory Standards Institute (CLSI) (2013) POCT 12-A3 point-of-care blood glucose testing in acute and chronic care facilities. Approved Guideline—3rd edn, vol 33. CLSI, Pennsylvania
    12.Sacks DB, Bruns DE, Goldstein DE, Maclaren NK, McDonald JM, Parrott M (2002) Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus. Clin Chem 48:426–472
    13.Bruns DE, Knowler WC (2009) Stabilization of glucose in blood samples: why it matters. Clin Chem 5:850CrossRef
    14.ISO 13528 (2005) Statistical methods for use in proficiency testing by interlaboratory comparisons. International Organization for Standardization, Geneva, Switzerland
    15.Food and Drug Administration (FDA) (2014) Blood glucose monitoring test systems for prescription point-of-care use. Draft Guidance for Industry and Food and Drug Administration Staff. http://​www.​fda.​gov . Accessed 15 May 2015
    16.Kuwa K, Nakayama T, Hoshino T, Tominaga M (2001) Relationships of glucose concentrations in capillary whole blood, venous whole blood and venous plasma. Clin Chim Acta 307:187–192CrossRef
    17.D’Orazio P, Burnett RW, Fogh-Andersen N, Jacobs E, Kuwa K, Külpmann WR, Larsson L, Lewenstam A, Maas AH, Mager G, Naskalski JW, Okorodudu AO (2005) Approved IFCC recommendation on reporting results for blood glucose. Clin Chem 9:51
    18.Dungan K, Chapman J, Braithwaite SS, Buse J (2007) Glucose measurement: confounding issues in setting targets for inpatient management. Diabetes Care 30:403–409CrossRef
    19.Walsh J, Roberts R, Vigersky RA, Schwartz F (2012) New criteria for assessing the accuracy of blood glucose monitors meeting. J Diabetes Sci Technol 6:466–474CrossRef
    20.Ginsberg B (2009) Factors affecting blood glucose monitoring: sources of errors in measurement. J Diabetes Sci Technol 3:903–913CrossRef
    21.Lyon ME, DuBois JA, Fick GH, Lyon AW (2010) Estimates of total analytical error in consumer and hospital glucose meters contributed by hematocrit, maltose, and ascorbate. J Diabetes Sci Technol 4:1479–1494CrossRef
    22.Pfützner A, Schipper C, Ramljak S, Flacke F, Sieber J, Forst T, Musholt PB (2013) Evaluation of the effects of insufficient blood volume samples on the performance of blood glucose self-test meters. J Diabetes Sci Technol 7:1522–1529
    23.Sociedade Brasileira de Patologia Clínica/Medicina Laboratorial (SBPC/ML) (2012) Diretriz para a Gestão e Garantia da Qualidade de testes laboratoriais remotos (TLR) da SBPC/ML. http://​www.​sbpc.​org.​br/​?​C=​16 . Accessed 21 May 2015
    24.Blank FS, Miller M, Nichols J, Smithline H, Crabb G, Pekow P (2009) Blood glucose measurement in patients with suspected diabetic ketoacidosis: a comparison of Abbott MediSense PCx point-of-care meter values to reference laboratory values. J Emerg Nurs 35:93–96CrossRef
    25.Joint Commission on the Accreditation of Healthcare Organizations (JCAHO) (2010) Accreditation standards for clinical laboratories. http://​pt.​jointcommissioni​nternational.​org/​enpt/​Clinical-laboratory . Accessed 10 July 2013
    26.Nakhleh RE (2013) Quality management tools. College of American Pathologists. Surveys & Anatomic Pathology Education Programs http://​www.​cap.​org . Accessed 21 May 2015
  • 作者单位:Angela Somavilla Higioka (1) (2)
    Renata Cristina Messores Rudolf-Oliveira (2) (3)
    Flavia Martinello (1) (4)
    Maria Luiza Bazzo (1) (2) (3)

    1. Residência Multidisciplinar em Saúde, University Hospital, Federal University of Santa Catarina, Florianópolis, Brazil
    2. Laboratório de Pesquisa III (segundo andar), Divisão de Análises Clínicas, Hospital Universitário Professor Polydoro Ernani de São Thiago - Universidade Federal de Santa Catarina, Campus Universitário, s/no, Trindade, Florianópolis, SC, CEP 88040-900, Brazil
    3. Program of Post Graduation in Pharmacy, Department of Clinical Analysis, Federal University of Santa Catarina, Florianópolis, Brazil
    4. Departamento de Análises Clínicas, Centro de Ciências da Saúde, Universidade Federal de Santa Catarina, sala 109, bloco JK, Trindade, Florianópolis, SC, CEP 88040-900, Brazil
  • 刊物类别:Chemistry and Materials Science
  • 刊物主题:Chemistry
    Analytical Chemistry
    Food Science
    Biochemistry
    Commercial Law
    Monitoring, Environmental Analysis and Environmental Ecotoxicology
    Marketing
  • 出版者:Springer Berlin / Heidelberg
  • ISSN:1432-0517
文摘
Point-of-care (POC) testing of glucose (glucometers) represents a convenient alternative to monitor glycemia since the measurement procedure is performed without delay after sampling of the capillary blood, thereby avoiding the metabolism by the blood cells of glucose present in plasma. Likely because of sample instability, there is no proficiency test provider in Brazil for this type of POC sample. In this context, this study aimed to evaluate the analytical performance of glucometers used in a tertiary care hospital. The glucometers used were the Accu-Chek Performa® model from Roche Diagnostics, which use the principle of amperometry. The reference method was the reaction with modified hexokinase/glucose-6-phosphate in a Dimension® device. The stability evaluation of the control samples showed that it can be performed up to 90 min after the collection of whole blood samples. In the two rounds performed, only one result of the 17 glucometers evaluated was out of the threshold of two standard deviation. Thus, this method for control of glucometers met the expectations and enabled comparing the glucometers in a hospital. Given the current quality guidelines, daily internal quality control of glucometers is recommended, besides at least two annual comparisons between the results of the glucometers and the reference method and one EQA every 3 months.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700