4-D MRI flow analysis in the course of interrupted aortic arch reveals complex morphology and quantifies amount of collateral blood flow
详细信息    查看全文
  • 作者:Daniel Hirtler (1)
    Julia Geiger (2)
    Bernd Jung (2)
    Michael Markl (3)
    Raoul Arnold (4)
  • 关键词:Interrupted aortic arch ; Flow ; sensitive 4 ; D MR ; Collateral blood flow ; Congenital heart disease
  • 刊名:Pediatric Radiology
  • 出版年:2013
  • 出版时间:August 2013
  • 年:2013
  • 卷:43
  • 期:8
  • 页码:1037-1040
  • 全文大小:329KB
  • 参考文献:1. Yu L, Shi E, Gu T (2011) Single-stage repair of interrupted aortic arch with simultaneous coronary artery bypass grafting without cardiopulmonary bypass in an adult. Ann Thorac Surg 92:1110鈥?113 CrossRef
    2. Sai Krishna C, Bhan A, Sharma S et al (2005) Interruption of aortic arch in adults: surgical experience with extra-anatomic bypass. Tex Heart Inst J 32:147鈥?50
    3. Markl M, Harloff A, Bley TA et al (2007) Time-resolved 3D MR velocity mapping at 3聽T: improved navigator-gated assessment of vascular anatomy and blood flow. J Magn Reson Imaging 25:824鈥?31 CrossRef
    4. Riehle TJ, Oshinski JN, Brummer ME et al (2006) Velocity-encoded magnetic resonance image assessment of regional aortic flow in coarctation patients. Ann Thorac Surg 81:1002鈥?007
    5. Pujadas S, Reddy GP, Weber O et al (2006) Phase contrast MR imaging to measure changes in collateral blood flow after stenting of recurrent aortic coarctation: initial experience. J Magn Reson Imaging 24:72鈥?6 CrossRef
    6. Stalder AF, Russe MF, Frydrychowicz A et al (2008) Quantitative 2D and 3D phase contrast MRI: optimized analysis of blood flow and vessel wall parameters. Magn Reson Med 60:1218鈥?231 CrossRef
    7. Nordmeyer S, Riesenkampff E, Crelier G et al (2010) Flow-sensitive four-dimensional cine magnetic resonance imaging for offline blood flow quantification in multiple vessels: a validation study. J Magn Reson Imaging 32:677鈥?83 CrossRef
  • 作者单位:Daniel Hirtler (1)
    Julia Geiger (2)
    Bernd Jung (2)
    Michael Markl (3)
    Raoul Arnold (4)

    1. Department of Pediatric Cardiology and Congenital Heart Disease, University Hospital Freiburg, Mathildenstr. 1, 79106, Freiburg, Germany
    2. Department of Radiology, Medical Physics, University Hospital Freiburg, Freiburg, Germany
    3. Departments of Radiology and Biomedical Engineering, Northwestern University, Chicago, IL, USA
    4. Department of Pediatric Cardiology and Congenital Heart Disease, University Hospital Heidelberg, Heidelberg, Germany
文摘
We present findings in a 17-year-old with interrupted aortic arch, in whom standard imaging techniques missed functional and morphological problems. Flow-sensitive four-dimensional magnetic resonance (4-D MR) enabled assessment of the complex anatomy and blood-flow characteristics in the entire aorta and direct quantification of blood flow in collateral vessels. Our findings highlight the entire morphological and functional problem of interrupted aortic arch and illustrate the potential of flow-sensitive 4-D MR for surgical planning in congenital heart disease.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700