Ceramic Liner Fracture and Impingement in Total Hip Arthroplasty
详细信息    查看全文
  • 作者:Amy Steinhoff MD (1)
    Victor Hakim MD (2)
    Richard H. Walker MD (3)
    Clifford W. Colwell Jr. MD (3) (4)
    Steven N. Copp MD (3)

    1. Department of Orthopedics
    ; Kaiser Permanente ; San Diego ; CA ; USA
    2. Hakim Joint Replacement
    ; Plano ; TX ; USA
    3. Division of Orthopaedic Surgery
    ; Scripps Clinic ; 10666 North Torrey Pines Road ; MS116 ; La Jolla ; CA ; 92037 ; USA
    4. Shiley Center for Orthopaedic Research & Education at Scripps Clinic
    ; La Jolla ; CA ; USA
  • 关键词:total hip arthroplasty ; ceramic fracture ; metallosis ; ceramic bearing ; acoustic phenomenon
  • 刊名:HSS Journal?
  • 出版年:2015
  • 出版时间:February 2015
  • 年:2015
  • 卷:11
  • 期:1
  • 页码:50-55
  • 全文大小:3,900 KB
  • 参考文献:1. Allain, J, Goutallier, D, Voisin, MC, Lemouel, S (1998) Failure of a stainless-steel femoral head of a revision total hip arthroplasty performed after a fracture of a ceramic femoral head. A case report. J Bone Joint Surg Am 80: pp. 1355-1360
    2. Allain, J, Roudot-Thoraval, F, Delecrin, J, Anract, P, Migaud, H, Goutallier, D (2003) Revision total hip arthroplasty performed after fracture of a ceramic femoral head. A multicenter survivorship study. J Bone Joint Surg 85-A: pp. 825-830
    3. Amanatullah, DF, Landa, J, Strauss, EJ, Garino, JP, Kim, SH, Cesare, PE (2011) Comparison of surgical outcomes and implant wear between ceramic-ceramic and ceramic-polyethylene articulations in total hip arthroplasty. J Arthroplasty 26: pp. 72-77 CrossRef
    4. Boutin, P, Christel, P, Dorlot, JM (1988) The use of dense alumina-alumina ceramic combination in total hip replacement. J Biomed Mater Res 22: pp. 1203-1232 CrossRef
    5. Chotai, PN, Su, EP (2011) Fracture of a titanium sleeve-encased third-generation ceramic liner in a modern THA. Orthopedics 34: pp. e682-e684
    6. D'Antonio, J, Capello, W, Manley, M, Bierbaum, B (2002) New experience with alumina-on-alumina ceramic bearings for total hip arthroplasty. J Arthroplasty 17: pp. 390-397 CrossRef
    7. D'Antonio, JA, Capello, WN, Manley, MT, Naughton, M, Sutton, K (2005) A titanium-encased alumina ceramic bearing for total hip arthroplasty: 3- to 5-year results. Clin Orthop Relat Res 441: pp. 151-158 CrossRef
    8. Fritsch, EW, Gleitz, M (1996) Ceramic femoral head fractures in total hip arthroplasty. Clin Orthop Relat Res 328: pp. 129-136 CrossRef
    9. Huet, R, Sakona, A, Kurtz, SM (2011) Strength and reliability of alumina ceramic femoral heads: Review of design, testing, and retrieval analysis. J Mech Behav Biomed Mater 4: pp. 476-483 CrossRef
    10. Jarrett, CA, Ranawat, AS, Bruzzone, M, Blum, YC, Rodriguez, JA, Ranawat, CS (2009) The squeaking hip: a phenomenon of ceramic-on-ceramic total hip arthroplasty. J Bone Joint Surg Am 91: pp. 1344-1349 CrossRef
    11. Kempf, I, Semlitsch, M (1990) Massive wear of a steel ball head by ceramic fragments in the polyethylene acetabular cup after revision of a total hip prosthesis with fractured ceramic ball. Arch Orthop Trauma Surg 109: pp. 284-287 CrossRef
    12. Mai, K, Verioti, C, Ezzet, KA, Copp, SN, Walker, RH, Colwell, CW (2010) Incidence of 'squeaking' after ceramic-on-ceramic total hip arthroplasty. Clin Orthop Relat Res 468: pp. 413-417 CrossRef
    13. Matziolis, G, Perka, C, Disch, A (2003) Massive metallosis after revision of a fractured ceramic head onto a metal head. Arch Orthop Trauma Surg 123: pp. 48-50
    14. Meftah, M, Ebrahimpour, PB, He, C, Ranawat, AS, Ranawat, CS (2011) Preliminary clinical and radiographic results of large ceramic heads on highly cross-linked polyethylene. Orthopedics 34: pp. 133
    15. Murali R, Bonar SF, Kirsh G, Walter WK, Walter WL. Osteolysis in third-generation alumina ceramic-on-ceramic hip bearings with severe impingement and titanium metallosis. / J Arthroplasty. 2008; 23(8): 1240.e13-e19.
    16. Nevelos, J, Ingham, E, Doyle, C (2000) Microseparation of the centers of alumina-alumina artificial hip joints during simulator testing produces clinically relevant wear rates and patterns. J Arthroplasty 15: pp. 793-795 CrossRef
    17. Orradre Burusco, I, Romero, R, Brun, M, Lopez Blasco, JJ (2011) Cross-linked ultra-high-molecular weight polyethylene liner and ceramic femoral head in total hip arthroplasty: a prospective study at 5 years follow-up. Arch Orthop Trauma Surg 131: pp. 1711-1716 CrossRef
    18. Ranawat, AS, Ranawat, CS (2007) The squeaking hip: a cause for concern-agrees. Orthopedics 30: pp. 738-743
    19. Restrepo, C, Parvizi, J, Kurtz, SM, Sharkey, PF, Hozack, WJ, Rothman, RH (2008) The noisy ceramic hip: is component malpositioning the cause?. J Arthroplasty 23: pp. 643-649 CrossRef
    20. Sedel, L (2000) Evolution of alumina-on-alumina implants: a review. Clin Orthop Relat Res 379: pp. 48-54 CrossRef
    21. Sharma, V, Ranawat, AS, Rasquinha, VJ, Weiskopf, J, Howard, H, Ranawat, CS (2010) Revision total hip arthroplasty for ceramic head fracture: a long-term follow-up. J Arthroplasty 25: pp. 342-347 CrossRef
    22. Walter, WL, O'Toole, GC, Walter, WK, Ellis, A, Zicat, BA (2007) Squeaking in ceramic-on-ceramic hips: the importance of acetabular component orientation. J Arthroplasty 22: pp. 496-503 CrossRef
    23. Willmann, G (2000) Ceramic femoral head retrieval data. Clin Orthop Relat Res 379: pp. 22-28 CrossRef
  • 刊物主题:Surgical Orthopedics; Orthopedics; Rheumatology; Sports Medicine; Imaging / Radiology; Anesthesiology;
  • 出版者:Springer US
  • ISSN:1556-3324
文摘
Background Ceramic-on-ceramic bearing surfaces were developed to provide an alternate to metal-on-polyethylene to decrease wear-induced osteolysis in total hip arthroplasty patients. In an effort to decrease the risk of ceramic acetabular component fracture or damage during implantation, a raised metal rim was added. Questions/Purposes How many fractures or impingements have occurred in our population of patients with ceramic liners with raised rims? Methods With IRB-approved consent, a case series was reviewed from a single center registry and 4 of 169 patients were identified who had revision hip surgery with the ceramic liner with a raised metal rim: one for ceramic liner fracture and three for metallosis, pain, and squeaking. Implant alignment and operative findings were reviewed. Results One ceramic liner fracture and three cases of metallosis from impingement of the femoral neck on the posterior elevated metal rim of the acetabular liner were observed at revision. The femoral neck in each patient had a divot that corresponded to a divot in the posterosuperior liner rim. Three of the four patients had audible squeaking or clicking prior to revision. A total of 3% of patients in this series had clinically significant impingement with this implant type. Conclusion Acoustic phenomenon in a ceramic on ceramic bearing surface should be investigated with a cross-table lateral radiograph to evaluate component position. If symptomatic impingement is demonstrated, revision should be considered to avoid failure from metallosis or fracture.