Effects of stemmed and nonstemmed hip replacement on stress distribution of proximal femur and implant
详细信息    查看全文
  • 作者:Chun-Ming Chen (1)
    Wen-Chi Tsai (2) (3)
    Shang-Chih Lin (4)
    Ching-Shiow Tseng (1)

    1. Department of Mechanical Engineering
    ; National Central University ; Taoyuan ; Taiwan
    2. BoneCare Orthopedic Centers
    ; Han-Chiung Clinics ; Taipei ; Taiwan
    3. Department of Orthopedic Surgery
    ; National Taiwan University Hospital ; Taipei ; Taiwan
    4. Graduate Institute of Biomedical Engineering
    ; National Taiwan University of Science and Technology ; No. 43 ; Sec. 4 ; Keelung Rd ; Taipei ; 106 ; Taiwan
  • 关键词:Hip ; Stemmed ; Nonstemmed ; Stress ; shielding ; Finite ; element
  • 刊名:BMC Musculoskeletal Disorders
  • 出版年:2014
  • 出版时间:December 2014
  • 年:2014
  • 卷:15
  • 期:1
  • 全文大小:1,405 KB
  • 参考文献:1. Callaghan, JJ, Forest, EE, Olejniczak, JP, Goetz, DD, Johnston, RC (1998) Charnley total hip arthroplasty in patients less than fifty years old. A twenty to twenty-five-year follow-up note. J Bone Joint Surg Am 80: pp. 704-714
    2. Chiu, KY, Ng, TP, Tang, WM, Poon, KC, Ho, WY, Yip, D (2001) Charnley total hip arthroplasty in Chinese patients less than 40聽years old. J Arthroplasty 16: pp. 92-101 CrossRef
    3. Keener, JD, Callaghan, JJ, Goetz, DD, Pederson, DR, Sullivan, PM, Johnston, RC (2003) Twenty-five-year results after Charnley total hip arthroplasty in patients less than fifty years old: a concise follow-up of a previous report. J Bone Joint Surg Am 85: pp. 1066-1072
    4. Park, YS, Lee, JY, Yun, SH, Jung, MW, Oh, I (2003) Comparison of hydroxyapatite- and porous-coated stems in total hip replacement. Acta Orthop Scand 74: pp. 259-263
    5. Epinette, JA, Manley, MT (2003) Fifteen years of clinical experience with hydroxyapatite coating in joint arthroplasty. Springer, Health and Medicine - Medical Specialties. Clinical, New York, pp. 217-224
    6. Lutz, A, Nackenhorst, U, Lewinski, G, Windhagen, H, Floerkemeier, T (2010) Numerical studies on alternative therapies for femoral head necrosis. A finite element approach and clinical experience. Biomech Model Mechanobiol 10: pp. 627-640 CrossRef
    7. Chen, WP, Tai, CL, Shih, CH, Hsieh, PH, Leou, MC, Lee, MS (2004) Selection of fixation devices in proximal femur rotational osteotomy: clinical complications and finite element analysis. Clin Biomech 19: pp. 255-262 CrossRef
    8. Mont, MA, Hungerford, DS (1995) Non-traumatic avascular necrosis of the femoral head. J Bone Joint Surg Am 77: pp. 459-474
    9. Siguier, T, Siguier, M, Judet, T, Charnley, G, Brumpt, B (2001) Partial resurfacing arthroplasty of the femoral head in avascular necrosis. Methods, Indications, and Results. Clin Orthop 386: pp. 85-92 CrossRef
    10. Orishimo, KF, Claus, AM, Sychterz, CJ, Engh, CA (2003) Relationship between polyethylene wear and osteolysis in hips with a second-generation porous-coated cementless cup after seven years of follow-up. J Bone Joint Surg Am 85: pp. 1095-1099
    11. Joshi, MG, Advani, SG, Miller, F, Santare, MH (2000) Analysis of a femoral hip prosthesis designed to reduce stress shielding. J Biomech 33: pp. 1655-1662 CrossRef
    12. Shih, CH, Chen, WP, Tai, CL, Kuo, RF, Wu, CC, Chen, CH (1997) New concepts-biomechanical studies of a newly designed femoral prosthesis (cervico-trochanter prosthesis). Clin Biomech 12: pp. 482-490 CrossRef
    13. Chen, WP, Tai, CL, Lee, MS, Lee, PC, Liu, CP, Shih, CH (2004) Comparison of stress shielding among different cement fixation modes of femoral stem in total hip arthroplasty 鈥?A three-dimensional finite element analysis. J Med Biol Eng 24: pp. 183-187
    14. Tai, CL, Chen, WP, Lee, MS, Lee, PC, Shih, CH (2004) Comparison of stress shielding between straight and curved stem in cementless total hip arthroplasty 鈥?an in vitro experimental study. J Med Biol Eng 24: pp. 177-181
    15. Padgett, DE, Warashina, H (2004) The unstable total hip replacement. Clin Orthop 420: pp. 72-79 CrossRef
    16. Maloney, WJ, Schmalzried, T, Harris, WH (2003) Analysis of long-term cemented total hip arthroplasty retrievals. Clin Orthop 405: pp. 70-78 CrossRef
    17. Bugbee, WD, Culpepper, WJ, Engh, CA, Engh, CA (1997) Long-term clinical consequences of stress-shielding after total hip arthroplasty without cement. J Bone Joint Surg Am 79: pp. 1007-1012
    18. Tai, CL, Shih, CH, Chen, WP, Lee, SS, Liu, YL, Hsieh, PH, Chen, WJ (2003) Finite element analysis of the cervico-trochanteric stemless femoral prosthesis. Clin Biomech 18: pp. S53-S58 CrossRef
    19. Munting, E, Verhelpen, M (1995) Fixation and effect on bone strain pattern of a stemless hip prosthesis. J Biomech 28: pp. 949-961 CrossRef
    20. Chen, TH, Lung, CY, Cheng, CK (2009) Biomechanical comparison of a new stemless hip prosthesis with different shapes-a finite element analysis. J Med Biol Eng 29: pp. 108-113
    21. Barrett, ARW, Davies, BL, Gomes, MPSF, Harris, SJ, Henckel, J, Jakopec, M, Baena, FMR, Cobb, JP (2006) Preoperative planning and intraoperative guidance for accurate computer-assisted minimally invasive hip resurfacing surgery. Proc IMechE Part H: J Eng Med 220: pp. 759-773 CrossRef
    22. Adams, D, Quigley, S (2005) Hip resurfacing: Past, present and future. J Orthop Nursing 9: pp. 87-94 CrossRef
    23. Amstutz, HC, Duff, MJL, Campbell, PA, Dorey, FJ (2007) The Effects of Technique Changes on Aseptic Loosening of the Femoral Component in Hip Resurfacing. J Arthroplasty 22: pp. 481-489 CrossRef
    24. Huang, CY, Luo, LJ, Lee, PY, Lai, JY, Wang, WT, Lin, SC (2010) Efficient segmentation algorithm for 3D bone models construction on medical images. J Med Biol Eng 31: pp. 375-386 CrossRef
    25. Brand, RA, Pedersen, DR, Friederich, JA (1986) The sensitivity of muscle force predictions to changes in physiologic cross-sectional area. J Biomech 19: pp. 589-596 CrossRef
    26. Huiskes, R, Boeklagen, R (1989) Mathematical shape optimization of hip prosthesis design. J Biomech 22: pp. 793-804 CrossRef
    27. Duda, GN, Brand, D, Freitag, S, Lierse, W, Schneider, E (1996) Variability of femoral muscle attachments. J Biomech 29: pp. 1185-1190 CrossRef
    28. Simoes, JA, Vaz, MA, Blatcher, S, Taylor, M (2000) Influence of head constraint and muscle forces on the strain distribution within the intact femur. Med Eng Phy 22: pp. 453-459 CrossRef
    29. Taylor, ME, Tanner, KE, Freeman, MAR, Yettram, AL (1996) Stress and strain distribution within the intact femur: compression or bending?. Med Eng Phy 18: pp. 122-131 CrossRef
    30. Shih, KS, Tseng, CS, Lee, CC, Lin, SC (2008) Influence of muscular contractions on the stress analysis of distal femoral interlocking nailing. Clin Biomech 23: pp. 38-44 CrossRef
    31. Hoffler, CE, Moore, KE, Kozloff, K, Zysset, PK, Goldstein, SA (2000) Age, gender, and bone lamellae elastic moduli. J Orthop Res 18: pp. 432-437 CrossRef
    32. Reilly, DT, Burstein, AH (1975) The elastic and ultimate properties of compact bone tissue. J Biomech 8: pp. 393-405 CrossRef
    33. Wirtz, DC, Schiffers, N, Pandorf, T, Radermacher, K, Weichert, D, Forst, R (2000) Critical evaluation of known bone material properties to realize anisotropic FE-simulation of the proximal femur. J Biomech 33: pp. 1325-1330 CrossRef
    34. Spears, IR, Morlock, MM, Pfleiderer, M, Schneider, E, Hille, E (1999) The influence of friction and interference on the seating of a hemispherical press-fit cup: a finite element investigation. J Biomech 32: pp. 1183-1189 CrossRef
    35. Nuno, N, Groppetti, R, Senin, N (2006) Static coefficient of friction between stainless steel and PMMA used in cemented hip and knee implants. Clin Biomech 21: pp. 956-962 CrossRef
    36. Chen, CC, Cheng, CT, Lin, CS, Lin, SC, Chiang, CC, Luo, CA, Tseng, CS (2014) Biomechanical effects of bone-implant fitness and screw breakage on the stability and stress performance of the nonstemmed hip system. Clin Biomech 29: pp. 161-169 CrossRef
    37. Asgari, SA, Hamouda, AMS, Mansor, SB, Singh, H, Mahdi, E, Wirza, R, Prakash, B (2004) Finite element modeling of a generic stemless hip implant design in comparison with conventional hip implants. Finite Elem Anal Des 40: pp. 2027-2047 CrossRef
    38. The pre-publication history for this paper can be accessed here:http://www.biomedcentral.com/1471-2474/15/312/prepub
  • 刊物主题:Orthopedics; Rehabilitation; Rheumatology; Sports Medicine; Internal Medicine;
  • 出版者:BioMed Central
  • ISSN:1471-2474
文摘
Background Despite improvements in shape, material, and coating for hip stem, both stress shielding and aseptic loosening have been the major drawbacks of stemmed hip arthroplasty. Some nonstemmed systems were developed to avoid rasping off the intramedullary canal and evacuating the bone marrow due to stem insertion. Methods In this study, the finite-element models of one intact, one stemmed, and two nonstemmed femora with minimal removal of the healthy neck were investigated to evaluate their biomechanical effects. The resurfacing (ball-shaped) and fitting (neck-shaped) systems were respectively selected as the representative of the ready- and custom-made nonstemmed implants. The stress distribution and interface micromotion were selected as the comparison indices. Results The results showed that stress distributions of the two nonstemmed femora are consistently more similar to the intact femur than the stemmed one. Around the proximal femur, the stem definitely induces the stress-shielding phenomenon of its counterparts. The fitting system with the anatomy-shaped cup can make intimate contact with the neck cortex and reduce the bone-cup micromotion and the implant stress. Comparatively, the reamed femoral head provides weaker support to the resurfacing cup causing higher interfacial micromotion. Conclusions The reserved femoral neck could act as the load-transferring medium from the acetabular cup, femoral neck, to the diaphysial bone, thus depressing the stress-shielding effect below the neck region. If the hip-cup construct can be definitely stabilized, the nonstemmed design could be an alternative of hip arthroplasty for the younger or the specific patients with the disease limited only to the femoral head.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700