Stainless steel versus titanium volar multi-axial locking plates for fixation of distal radius fractures: a randomised clinical trial
详细信息    查看全文
  • 作者:Gregory B Couzens ; Susan E Peters ; Kenneth Cutbush…
  • 关键词:Distal radius ; Randomized trial ; Volar plating ; Trimed ; Medartis ; Wrist ; Surgery
  • 刊名:BMC Musculoskeletal Disorders
  • 出版年:2014
  • 出版时间:December 2014
  • 年:2014
  • 卷:15
  • 期:1
  • 全文大小:287 KB
  • 参考文献:1. Court-Brown, CM, Caesar, B (2006) Epidemiology of adult fractures: a review. Injury 37: pp. 691-697 CrossRef
    2. Yu, YR, Makhni, MC, Tabrizi, S, Rozental, TD, Mundanthanam, G, Day, CS (2011) Complications of low-profile dorsal versus volar locking plates in the distal radius: a comparative study. J Hand Surg 36A: pp. 1135-1141 CrossRef
    3. Gehrmann, SV, Windolf, J, Kaufmann, RA (2008) Distal radius fracture management in elderly patients: a literature review. J Hand Surg 33A: pp. 421-429 CrossRef
    4. Park, JH, Hagopian, J, Ilyas, AM (2010) Variable-angle locking screw volar plating of distal radius fractures. Hand Clinics 26: pp. 373-380 CrossRef
    5. Wolfe, SW, Hotchkiss, RN, Pederson, WC, Kozin, SH (2011) Green’s Operative Hand Surgery. Elsevier, New York
    6. Lam, J, Wolfe, SW (2010) Distal radius fractures: what cannot be fixed with a volar plate? The role of fragment-specific fixation in modern fracture treatment. Op Tech Sports Med 18: pp. 181-188 CrossRef
    7. Margliot, Z, Haase, SC, Kotsis, SV, Kim, HM, Chung, KC (2005) A meta-analysis of outcomes of external fixation versus plate osteosynthesis for unstable distal radius fractures. J Hand Surg 30A: pp. 1185-1199
    8. Ross, M, Heiss-Dunlop, W Volar angle stable plating for distal radius fractures. In: Slutsky, DJ eds. (2010) Principles and Practice of Wrist Surgery. Elsevier, Philadelphia, pp. 126-139
    9. Osada, D, Kamei, S, Masuzaki, K, Takai, M, Kameda, M, Tamai, K (2008) Prospective study of distal radius fractures treated with a volar locking plate system. J Hand Surg 33A: pp. 691-700 CrossRef
    10. Richards, MJ, Wartinbee, DA, Riboh, J, Miller, M, Leversedge, FJ, Ruch, DS (2011) Analysis of the complications of palmar plating versus external fixation of the distal radius. J Hand Surg 36A: pp. 1614-1620 CrossRef
    11. Soong, M, van Leerdam, R, Guitton, TG, Got, C, Katarincic, J, Ring, D (2011) Fracture of the distal radius: Risk factors for complications after locked volar plate fixation. J Hand Surg 36A: pp. 3-9 CrossRef
    12. Grewal, R, MacDermaid, JC, King, GJ, Faber, KJ (2011) Open reduction internal fixation versus percutanous pinning with external fixation of distal radius fractures: a prospective, randomized clinical trial. J Hand Surg 36A: pp. 1899-1906 CrossRef
    13. Souer, JS, Ring, D, Matschke, S, Audige, L, Maren-Hubert, M, Jupiter, J (2010) Comparison of functional outcome after volar plate fixation with 2.4?mm Titanium versus 3.5?mm Stainless-steel plate for extra-articular fracture of distal radius. J Hand Surg 35A: pp. 398-405 CrossRef
    14. Crespo MR, S - del Canto-Alvarez, F, de Diego-Gutierrez, V, Gutierrez-Santiago, M, Sanchez-Juan, P (2009) Functional results and complications of locked distal radius volar plates. Revista Espanola de Giruga Orthopedica y Traumatologia 53: pp. 381-385 CrossRef
    15. Cohen, MS, Turner, TM, Urban, RM (2006) Effects of implant material and plate design on tendon function and morphology. Clin Orthop Relat Res 445: pp. 81-90
    16. Ring, D, Jupiter, JB, Brennwald, J, Buchler, U (1997) Prospective multicenter trial of a plate for dorsal fixation of distal radius fractures. J Hand Surg 22A: pp. 777-784 CrossRef
    17. MacDermid, JC, Turgeon, T, Richards, R, Beadle, M, Roth, JH (1998) Patient rating of wrist pain and disability: a reliable and valid measurement tool. J Orth Traum 12: pp. 577-586
  • 刊物主题:Orthopedics; Rehabilitation; Rheumatology; Sports Medicine; Internal Medicine;
  • 出版者:BioMed Central
  • ISSN:1471-2474
文摘
Background Distal radius fractures are among the most common fractures seen in the hospital emergency department. Of these, over 40% are considered unstable and require some form of fixation. In recent years with the advent of low profile plating, open reduction and internal fixation (ORIF) using volar plates has become the surgical treatment of choice in many hospitals. However, it is currently unknown which plating system has the lowest complication rate and/or superior clinical and radiological outcomes following surgery. Few studies have compared different types of plates, which may have various features, different plate and screw designs or may be manufactured from different materials (for example, stainless steel or titanium). This study will specifically investigate and compare the clinical and radiological outcomes and complication rates of two commonly used volar plating systems for fixation of distal radius fractures: one made from stainless steel (Trimed?Volar Plate, Trimed? California, USA) and the other made from titanium (Medartis? Aptus Volar Plate, Medartis?, Basel, Switzerland). The primary aim of this study is to determine if there is a difference on the Patient Reported Wrist Evaluation six months following ORIF using a volar plate for adult patients with a distal radius fracture. Methods/Design This study will implement a randomized prospective clinical trial study design evaluating the outcomes of two different types of volar plates: one plate manufactured from stainless steel (Trimed?Volar Plate) and one plate manufactured from titanium (Medartis? Aptus Volar Plate). The surgery will be performed at a major trauma hospital in Brisbane, Australia. Outcome measures including function, adverse events, range of movement, strength, disability, radiological findings and health-related quality of life will be collected at 6?weeks, 3, 6, 12 and 24?months following surgery. A parallel economic analysis will also be performed. This randomized clinical trial is due to deliver results in December 2016. Discussion Results from this trial will contribute to the evidence on operative management of distal radius fractures and plate material type. Trial registration ACTRN12612000969864

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700