Passive leg raising: five rules, not a drop of fluid!
详细信息    查看全文
  • 作者:Xavier Monnet (1) (2)
    Jean-Louis Teboul (1) (2)

    1. Service de r茅animation m茅dicale
    ; H么pital de Bic锚tre ; H么pitaux Universitaires Paris-Sud ; 78 ; rue du G茅n茅ral Leclerc ; Le Kremlin-Bic锚tre ; Paris ; F-94270 ; France
    2. Facult茅 de m茅decine Paris-Sud
    ; Universit茅 Paris-Sud ; EA4533 ; Le Kremlin-Bic锚tre ; Paris ; F-94270 ; France
  • 刊名:Critical Care
  • 出版年:2015
  • 出版时间:December 2015
  • 年:2015
  • 卷:19
  • 期:1
  • 全文大小:44 KB
  • 参考文献:1. Monnet X, Rienzo M, Osman D, Anguel N, Richard C, Pinsky MR, Teboul JL: Passive leg raising predicts fluid responsiveness in the critically ill. / Crit Care Med 2006, 34:1402鈥?407. CrossRef
    2. Jabot J, Teboul JL, Richard C, Monnet X: Passive leg raising for predicting fluid responsiveness: importance of the postural change. / Intensive Care Med 2009, 35:85鈥?0. CrossRef
    3. Boulain T, Achard JM, Teboul JL, Richard C, Perrotin D, Ginies G: Changes in BP induced by passive leg raising predict response to fluid loading in critically ill patients. / Chest 2002, 121:1245鈥?252. CrossRef
    4. Lakhal K, Ehrmann S, Runge I, Benzekri-Lefevre D, Legras A, Dequin PF, Mercier E, Wolff M, Regnier B, Boulain T: Central venous pressure measurements improve the accuracy of leg raising-induced change in pulse pressure to predict fluid responsiveness. / Intensive Care Med 2010, 36:940鈥?48. CrossRef
    5. Monnet X, Bataille A, Magalhaes E, Barrois J, Le Corre M, Gosset C, Guerin L, Richard C, Teboul JL: End-tidal carbon dioxide is better than arterial pressure for predicting volume responsiveness by the passive leg raising test. / Intensive Care Med 2013, 39:93鈥?00. CrossRef
    6. Bubenek-Turconi SI, Craciun M, Miclea I, Perel A: Noninvasive continuous cardiac output by the Nexfin before and after preload-modifying maneuvers: a comparison with intermittent thermodilution cardiac output. / Anesth Analg 2013, 117:366鈥?72. CrossRef
    7. Marik PE, Levitov A, Young A, Andrews L: The use of bioreactance and carotid Doppler to determine volume responsiveness and blood flow redistribution following passive leg raising in hemodynamically unstable patients. / Chest 2013, 143:364鈥?70. CrossRef
    8. Kupersztych-Hagege E, Teboul JL, Artigas A, Talbot A, Sabatier C, Richard C, Monnet X: Bioreactance is not reliable for estimating cardiac output and the effects of passive leg raising in critically ill patients. / Br J Anaesth 2013, 111:961鈥?66. CrossRef
    9. Mahjoub Y, Touzeau J, Airapetian N, Lorne E, Hijazi M, Zogheib E, Tinturier F, Slama M, Dupont H: The passive leg-raising maneuver cannot accurately predict fluid responsiveness in patients with intra-abdominal hypertension. / Crit Care Med 2010, 38:1824鈥?829. CrossRef
    10. Malbrain ML, Reuter DA: Assessing fluid responsiveness with the passive leg raising maneuver in patients with increased intra-abdominal pressure: be aware that not all blood returns! / Crit Care Med 2010, 38:1912鈥?915. CrossRef
    11. Cavallaro F, Sandroni C, Marano C, La Torre G, Mannocci A, De Waure C, Bello G, Maviglia R, Antonelli M: Diagnostic accuracy of passive leg raising for prediction of fluid responsiveness in adults: systematic review and meta-analysis of clinical studies. / Intensive Care Med 2010, 36:1475鈥?483. CrossRef
    12. Vincent JL, Weil MH: Fluid challenge revisited. / Crit Care Med 2006, 34:1333鈥?337. CrossRef
  • 刊物主题:Intensive / Critical Care Medicine; Emergency Medicine;
  • 出版者:BioMed Central
  • ISSN:1364-8535
文摘

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700