Determination of Gastrodin and Ligustrazine Hydrochloride in Plasma and Brain Dialysate by LC¨CTandem MS
详细信息    查看全文
文摘
A gradient liquid chromatography-tandem mass spectrometry method has been developed and validated for the determination of gastrodin and ligustrazine hydrochloride in rat plasma and brain dialysates. Zolpidem was used as internal standard. For plasma samples, solid-phase extraction was used and the brain dialysates were collected from freely moving rats using brain microdialysis. Both were followed by HPLC separation and positive electrospray ionization tandem mass spectrometry detection (ESI–MS–MS). Chromatographic separation was achieved on a Symmetry RP-18 column using gradient elution with methanol and water containing 0.5 % formic acid and 2 mM ammonium formate. Selected reaction monitoring (SRM) mode was used for quantitation. Good linearities were obtained in the range of 0.05–100 and 0.01–50 μg mL−1 for gastrodin and ligustrazine hydrochloride in rat plasma, and 0.05–1,000 ng mL−1 for both in dialysate. The lower limit of quantitation was 0.01 ng mL−1 for gastrodin and 0.05 ng mL−1 for ligustrazine. The method is precise and reliable and can be applied to pharmacokinetic studies.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700