Performance of one-view breast tomosynthesis as a stand-alone breast cancer screening modality: results from the Malm枚 Breast Tomosynthesis Screening Trial, a population-based study
参考文献:1.Independent UK Panel on Breast Cancer Screening (2012) The benefits and harms of breast cancer screening: an independent review. Lancet 380:1778鈥?786CrossRef 2.Laming D, Warren R (2000) Improving the detection of cancer in the screening of mammograms. J Med Screen 7:24鈥?0CrossRef PubMed 3.Bochud FO, Valley JF, Verdun FR et al (1999) Estimation of the noisy component of anatomical backgrounds. Med Phys 26:1365鈥?370CrossRef PubMed 4.Carney PA, Miglioretti DL, Yankaskas BC et al (2003) Individual and combined effects of age, breast density, and hormone replacement therapy use on the accuracy of screening mammography. Ann Intern Med 138:168鈥?75CrossRef PubMed 5.Baker JA, Lo JY (2011) Breast tomosynthesis: state-of-the-art and review of the literature. Acad Radiol 18:1298鈥?10CrossRef PubMed 6.Niklason LT, Christian BT, Niklason LE et al (1997) Digital tomosynthesis in breast imaging. Radiology 205:399鈥?06CrossRef PubMed 7.Houssami N, Skaane P (2013) Overview of the evidence on digital breast tomosynthesis in breast cancer detection. Breast 22:101鈥?08CrossRef PubMed 8.Lei J, Yang P, Zhang L et al (2013) Diagnostic accuracy of digital breast tomosynthesis versus digital mammography for benign and malignant lesions in breasts: a meta-analysis. Eur Radiol 24:595鈥?02CrossRef 9.Andersson I, Ikeda DM, Zackrisson S et al (2008) Breast tomosynthesis and digital mammography: a comparison of breast cancer visibility and BIRADS classification in a population of cancers with subtle mammographic findings. Eur Radiol 18:2817鈥?825CrossRef PubMed 10.Svahn TM, Chakraborty DP, Ikeda D et al (2012) Breast tomosynthesis and digital mammography: a comparison of diagnostic accuracy. Br J Radiol 85:e1074鈥?2PubMedCentral CrossRef PubMed 11.Ciatto S, Houssami N, Bernardi D et al (2013) Integration of 3D digital mammography with tomosynthesis for population breast-cancer screening (STORM): a prospective comparison study. Lancet Oncol 14:583鈥?89CrossRef PubMed 12.Skaane P, Bandos AI, Gullien R et al (2013) Comparison of digital mammography alone and digital mammography plus tomosynthesis in a population-based screening program. Radiology 267:47鈥?6CrossRef PubMed 13.Haas BM, Kalra V, Geisel J et al (2013) Comparison of tomosynthesis plus digital mammography and digital mammography alone for breast cancer screening. Radiology 269:694鈥?00CrossRef PubMed 14.Friedewald SM, Rafferty EA, Rose SL et al (2014) Breast cancer screening using tomosynthesis in combination with digital mammography. JAMA 311:2499鈥?07CrossRef PubMed 15.The National Board of Health and Welfare. (2007) [The National Guidelines for breast-, colorectal and prostate cancer]. Stockholm, Sweden. Available via http://鈥媤ww.鈥媠ocialstyrelsen.鈥媠e/鈥媙ationellariktli鈥媙jerforbrostpros鈥媡atatjocktarmsoc鈥媓andtarmscancerv鈥媋rd . Accessed 9 Sep 2014 16.Van Engen R, Bouwman R, Dance D, Heid P, Lazzari B, Marshall N, Schopphoven S, Strudley C, Thjissen M, Young K BH (2013) Protocol for the quality control of the physical and technical aspects of digital breast tomosynthesis system. EUREF, European Guidelines for Quality Assurance in Breast Cancer Screening and Diagnosis 17.Hemdal B (2011) Forward-scattered radiation from the compression paddle should be considered in glandular dose estimations. Radiat Prot Dosim 147:196鈥?01CrossRef 18.Mertelmeier T (2006) Optimizing filtered backprojection reconstruction for a breast tomosynthesis prototype device. Proc SPIE. doi:10.鈥?117/鈥?2.鈥?51380 19.F枚rnvik D, Andersson I, Svahn T, et al. The effect of reduced breast compression in breast tomosynthesis: human observer study using clinical cases. Radiat Prot Dosimetry 139:118鈥?3 20.D鈥橭rsi CJ, Mendelson EB, Morris EASEA (2013) ACR BI-RADS庐 Atlas, Breast Imaging Reporting and Data System. American College of Radiology, Reston, VA 21.Sullivan M (2003) The statistical evaluation of medical tests for classification and prediction, 2nd edn. Oxford University Press Inc, New York, pp 230鈥?33 22.Tabar L, Fagerberg CJ, Gad A et al (1985) Reduction in mortality from breast cancer after mass screening with mammography. Randomised trial from the Breast Cancer Screening Working Group of the Swedish National Board of Health and Welfare. Lancet 1:829鈥?32CrossRef PubMed 23.F枚rnvik D, Zackrisson S, Ljungberg O et al (2010) Breast tomosynthesis: Accuracy of tumor measurement compared with digital mammography and ultrasonography. Acta Radiol 51:240鈥?47CrossRef PubMed 24.Evans AJ, Pinder SE, James JJ et al (2006) Is mammographic spiculation an independent, good prognostic factor in screening-detected invasive breast cancer? AJR Am J Roentgenol 187:1377鈥?380CrossRef PubMed 25.Perry N, Broeders M, de Wolf C et al (2008) European guidelines for quality assurance in breast cancer screening and diagnosis. Fourth edition鈥攕ummary document. Ann Oncol 19:614鈥?22CrossRef PubMed 26.Lundgren B, Helleberg A (1982) Single oblique-view mammography for periodic screening for breast cancer in women. J Natl Cancer Inst 68:351鈥?55PubMed 27.Dustler M, F枚rnvik D, Timberg P, Tingberg A (2013) A Study of the Feasibility of using slabbing to reduce Tomosynthesis Review Time. Proc SPIE. doi:10.鈥?117/鈥?2.鈥?006987 28.Stout NK, Rosenberg MA, Trentham-Dietz A et al (2006) Retrospective cost-effectiveness analysis of screening mammography. J Natl Cancer Inst 98:774鈥?2CrossRef PubMed
1. Department of Diagnostic Radiology, Translational Medicine Malm枚, Lund University, Inga Marie Nilssons gata 49, SE-20502, Malm枚, Sweden 2. Epidemiology and Register Centre South, Sk氓ne University Hospital, Klinikgatan 22, SE-221 85, Lund, Sweden 3. Department of Medical Radiation Physics, Translational Medicine Malm枚, Lund University, Inga Marie Nilssons gata 49, SE-20502, Malm枚, Sweden
刊物类别:Medicine
刊物主题:Medicine & Public Health Imaging and Radiology Diagnostic Radiology Interventional Radiology Neuroradiology Ultrasound Internal Medicine
出版者:Springer Berlin / Heidelberg
ISSN:1432-1084
文摘
Objective To assess the performance of one-view digital breast tomosynthesis (DBT) in breast cancer screening.