Reconstruction of the treatment area by use of sinogram in helical tomotherapy
详细信息    查看全文
  • 作者:Akihiro Haga (1)
    Keiichi Nakagawa (1)
    Calvin Maurer (2)
    Ken Ruchala (2)
    Edward Chao (2)
    Dylan Casey (2)
    Satoshi Kida (1)
    Dousatsu Sakata (1)
    Masahiro Nakano (1)
    Taiki Magome (1)
    Yoshitaka Masutani (1)

    1. Department of Radiology
    ; University of Tokyo Hospital ; 7-3-1 Hongo ; Bunkyo ; Tokyo ; Japan
    2. Accuray Incorporated
    ; Sunnyvale ; CA ; USA
  • 关键词:Megavoltage CT ; In ; treatment CT ; Image reconstruction during treatment ; TomoTherapy庐
  • 刊名:Radiation Oncology
  • 出版年:2014
  • 出版时间:December 2014
  • 年:2014
  • 卷:9
  • 期:1
  • 全文大小:543 KB
  • 参考文献:ICRU Report 83: Prescribing, recording, and reporting photon-beam intensity-modulated radiation therapy (IMRT). J ICRU 10: pp. 1-106 CrossRef
    1. Balter, JM, Lam, KL, Sandler, HM, Littles, JF, Bree, RL, Haken, RK (1995) Automated localization of the prostate at the time of treatment using implanted radiopaque markers: technical feasibility. Int J Radiat Oncol Biol Phys 33: pp. 1281-1286 CrossRef
    2. Alasti, H, Petric, MP, Catton, CN, Warde, PR (2001) Portal imaging for evaluation of daily on-line setup errors and off-line organ motion during conformal irradiation of carcinoma of the prostate. Int J Radiat Oncol Biol Phys 49: pp. 869-884 CrossRef
    3. Bergstrom, P, Lofrot, PO, Widmark, A (1998) High-precision conformal radiotherapy (HPCRT) of prostate cancer鈥撯€揳 new technique for exact positioning of the prostate at the time of treatment. Int J Radiat Oncol Biol Phys 42: pp. 305-311 CrossRef
    4. Vigneault, E, Pouliot, J, Laverdiere, J, Roy, J, Dorion, M (1997) Electronic portal imaging device detection of radioopaque markers for the evaluation of prostate position during megavoltage irradiation: a clinical study. Int J Radiat Oncol Biol Phys 37: pp. 205-212 CrossRef
    5. Mah, D, Freedman, G, Milestone, B, Hanlon, A, Palacio, E, Richardson, T, Movsas, B, Mitra, R, Horwitz, E, Hanks, GE (2002) Measurement of intrafractional prostate motion using magnetic resonance imaging. Int J Radiat Oncol Biol Phys 54: pp. 568-575 CrossRef
    6. Chandra, A, Dong, L, Huang, E, Kuban, DA, O鈥橬eill, L, Rosen, I, Pollack, A, Kuban, DA, O鈥橬eill, L, Rosen, I, Pollack, A (2003) Experience of ultrasound-based daily prostate localization. Int J Radiat Oncol Biol Phys 56: pp. 436-447 CrossRef
    7. Morr, J, DiPetrillo, T, Tsai, JS, Engler, M, Wazer, DE (2002) Implementation and utility of a daily ultrasound-based localization system with intensity-modulated radiotherapy for prostate cancer. Int J Radiat Oncol Biol Phys 53: pp. 1124-1129 CrossRef
    8. Herk, M, Bruce, A, Kroes, AP, Shouman, T, Touw, A, Lebesque, JV (1995) Quantification of organ motion during conformal radiotherapy of the prostate by three dimensional image registration. Int J Radiat Oncol Biol Phys 33: pp. 1311-1320 CrossRef
    9. Jaffray, DA, Siewerdsen, JH, Wong, JW, Martinez, AA (2002) Flat-panel cone-beam computed tomography for image-guided radiation therapy. Int J Radiat Oncol Biol Phys 53: pp. 1337-1349 CrossRef
    10. Ruchala, KJ, Olivera, GH, Schloesser, EA, Mackie, TR (1999) Megavoltage CT on a tomotherapy system. Phys Med Biol 44: pp. 2597-2621 CrossRef
    11. Sevillano, D, M铆nguez, C, S谩nchez, A, S谩nchez-Reyes, A (2012) Measurement and correction of leaf open times in helical tomotherapy. Med Phys 39: pp. 6972-6980 CrossRef
    12. Hashimoto, M, Uematsu, M, Ito, M, Hama, Y, Inomata, T, Fujii, M, Nishio, T, Nakamura, N, Nakagawa, K (2012) Investigation of the feasibility of a simple method for verifying the motion of a binary multileaf collimator synchronized with rotation of the gantry for helical tomotherapy. J Appl Clin Med Phys 13: pp. 27-43
    13. Poludniowski, G, Thomas, MDR, Evans, PM, Webb, S (2011) CT reconstruction from portal images acquired during volumetric-modulated arc therapy. Phys Med Biol 55: pp. 5635-5651 CrossRef
    14. Kida, S, Saotome, N, Masutani, Y, Yamashita, H, Ohtomo, K, Nakagawa, K, Sakumi, A, Haga, A (2011) 4D-CBCT reconstruction using MV portal imaging during volumetric modulated arc therapy. Radiother Oncol 100: pp. 380-385 CrossRef
    15. Ruchala, KJ, Olivera, GH, Kapatoes, JM, Schloesser, EA, Reckwerdt, PJ, Mackie, TR (2000) Megavoltage CT image reconstruction during tomotherapy treatments. Phys Med Biol 45: pp. 3545-3562 CrossRef
  • 刊物主题:Oncology; Radiotherapy;
  • 出版者:BioMed Central
  • ISSN:1748-717X
文摘
Background TomoTherapy (Accuray, USA) has an image-guided radiotherapy system with a megavoltage (MV) X-ray source and an on-board imaging device. This system allows one to acquire the delivery sinogram during the actual treatment, which partly includes information from the irradiated object. In this study, we try to develop image reconstruction during treatment with helical tomotherapy. Findings Sinogram data were acquired during helical tomotherapy delivery using an arc-shaped detector array that consists of 576 xenon-gas filled detector cells. In preprocessing, these were normalized with full air-scan data. A software program was developed that reconstructs 3D images during treatment with corrections as; (1) the regions outside the field were masked not to be added in the backprojection (a masking correction), and (2) each voxel of the reconstructed image was divided by the number of the beamlets passing through its voxel (a ray-passing correction). The masking correction produced a reconstructed image, however, it contained streak artifacts. The ray-passing correction reduced this artifact. Although the SNR (the ratio of mean to standard deviation in a homogeneous region) and the contrast of the reconstructed image were slightly improved with the ray-passing correction, use of only the masking correction was sufficient for the visualization purpose. Conclusions The visualization of the treatment area was feasible by using the sinogram in helical tomotherapy. This proposed method would be useful in the treatment verification.