A study on the dependence of the change in total scan time on the timing of the scan-time determination
详细信息    查看全文
  • 作者:Jong-Hun Lee (1919)
    Woo-Young Jung (1919)
    Ho-Sung Kim (1919)
    Mi-Hyun Kim (2919) (3919)
    Woon-Kwan Chung (4919)
    Jae-Hwan Cho (5919)
  • 关键词:Total scan time ; Dose ; Detector
  • 刊名:Journal of the Korean Physical Society
  • 出版年:2013
  • 出版时间:March 2013
  • 年:2013
  • 卷:62
  • 期:5
  • 页码:820-825
  • 全文大小:170KB
  • 参考文献:1. C. Nichol and E. E. Kim, J. Nucl. Med. 42, 1368 (2001).
    2. S. H. Britz-Cunningham and S. J. Adelstein, J. Nucl. Med. 44, 1945 (2003).
    3. R. Weissleder and U. Mahmood, Radiology 219, 316 (2001).
    4. J. S. Mulligan, P. W. Blue and J. A. Hasbargen, J. Nucl. Med. 31, 1211 (1990).
    5. G. F. Gates, J. Nucl. Med. 25, 613 (1984).
    6. R. Puchal, J. Pavia, A. Gonzalez and D. Ros, Phys. Med. Biol. 33, 831 (1988). CrossRef
    7. T. Sharir, D. S. Berman, P. B. Waechter, J. Areeda, P. B. Kavanagh and J. Gerlach, J. Nucl. Med. 42, 1630 (2001).
    8. S. R. Cherry, J. A. Sorenson and M. E. Phelps, / Physics in Nuclear Medicine, 3rd ed. (Saunders, Philadelphia, 2002).
    9. K. H. Lee, / Computers in Nuclear Medicine: A Practical Approach (The Society of Nuclear Medicine, New York, 1991).
    10. M. M. Khalil, / Basic Sciences of Nuclear Medicine (Springer, New York, 2011). CrossRef
    11. M. S. Rosenthal, J. Cullom, W. Hawkins, S. C. Moore, B. M. Tsui and M. Yester, J. Nucl. Med. 36, 1489 (1995).
    12. M. H. Li, H. S. Bom, A. S. Kwon, Y. H. Kim and J. Y. Kim, J. Korean Asso. Radiat. Prot. 28, 117 (2003).
    13. A. Steinstrasser, R. Berberich, L. Kuhlmann, S. Zabori and A. Schwarz, Nucl. Med. 31, 57 (1992).
    14. P. P. Bruyant, J. Nucl. Med. 43, 1343 (2002).
    15. M. M. Khalil, / Basic Sciences of Nuclear Medicine (Springer, Berlin, 2010).
  • 作者单位:Jong-Hun Lee (1919)
    Woo-Young Jung (1919)
    Ho-Sung Kim (1919)
    Mi-Hyun Kim (2919) (3919)
    Woon-Kwan Chung (4919)
    Jae-Hwan Cho (5919)

    1919. Department of Nuclear Medicine, Asan Medical Center, Seoul, 138-736, Korea
    2919. Department of Radiological Technology, Gwangju Health University, Gwangju, 501-701, Korea
    3919. Department of Radiation Science & Technology, Chonbuk National University, Jeonju, 561-756, Korea
    4919. Department of Nuclear Engineering, Chosun University, Gwangju, 501-759, Korea
    5919. Department of International Radiological Science, Hallym University of Graduate Studies, Seoul, 135-841, Korea
  • ISSN:1976-8524
文摘
This study examined the change in the scan time according to the scan-time determination in an examination by using a pre-set time to identify a reasonable alternative to altering the scan time. A hepatobiliary scan was conducted using the radiopharmaceutical 99m Tc-mebrofenin in the Nuclear Medicine Department of Asan Medical Center from January to March 2012. Scanning began five minutes after an intravenous injection of 222 MBq (megabecquere) (6 mCi). As two detectors were placed facing each other, the patient was asked to stand between the two detectors with the front of the abdomen pressed as close as possible against the detector. After scanning, the measurement was carried out to determine the expected end time of scanning when the scan time was 10, 25, 50, and 75% of the total scan time. After scanning had been completed, the measurement time was compared with the final scan time and the expected scan time in the middle of scanning. A phantom was also used to examine the dependence of the change in time on the dose. The difference was examined when the scan time was 10, 25, 50, and 75% of the total expected scan time after beginning the scan. According to the study results, the difference was five seconds or more at the maximum when the scan time was 10% of the total expected scan time. The difference was significant when the scan time was 25% or 50% of the total expected scan time.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700