Feasibility of three-dimensional ultrashort echo time magnetic resonance imaging at 1.5 T for the diagnosis of skull fractures
详细信息    查看全文
  • 作者:Hao Wu ; Yu-min Zhong ; Quan-min Nie ; Wei-bo Chen ; Lie-mei Guo ; Xi Yang…
  • 关键词:Ultrashort echo time ; Skull fracture ; Magnetic resonance imaging ; Computed tomography ; Radiation
  • 刊名:European Radiology
  • 出版年:2016
  • 出版时间:January 2016
  • 年:2016
  • 卷:26
  • 期:1
  • 页码:138-146
  • 全文大小:1,064 KB
  • 参考文献:1.Schmidt CW (2012) CT scans: balancing health risks and medical benefits. Environ Health Perspect 120:A118鈥揂121PubMedCentral CrossRef PubMed
    2.Hall EJ, Brenner DJ (2012) Cancer risks from diagnostic radiology: the impact of new epidemiological data. Br J Radiol 85:e1316鈥揺1317PubMedCentral CrossRef PubMed
    3.Nievelstein RA, van Dam IM, van der Molen AJ (2010) Multidetector CT in children: current concepts and dose reduction strategies. Pediatr Radiol 40:1324鈥?344PubMedCentral CrossRef PubMed
    4.Frush DP (2011) CT dose and risk estimates in children. Pediatr Radiol 41:483鈥?87CrossRef PubMed
    5.McCollough CH, Schueler BA, Atwell TD, Braun NN, Regner DM, Brown DL et al (2010) Radiation exposure and pregnancy: when should we be concerned? Radiographics 27:909鈥?17CrossRef
    6.Yamashita K, Yoshiura T, Hiwatashi A, Kamano H, Honda H (2012) Ultrashort echo time imaging of normal middle ear ossicles: a feasibility study. Dentomaxillofac Radiol 41:601鈥?04PubMedCentral CrossRef PubMed
    7.Robson MD, Gatehouse PD, Bydder M, Bydder GM (2003) Magnetic resonance: an introduction to ultrashort TE (UTE) imaging. J Comput Assist Tomogr 27:825鈥?46CrossRef PubMed
    8.Bae WC, Du J, Bydder GM, Chung CB (2010) Conventional and ultrashort time-to-echo magnetic resonance imaging of articular cartilage, meniscus, and intervertebral disk. Top Magn Reson Imaging 21:275鈥?89PubMedCentral CrossRef PubMed
    9.Du J, Bydder M, Takahashi AM, Carl M, Chung CB, Bydder GM (2011) Short T2 contrast with three-dimensional ultrashort echo time imaging. Magn Reson Imaging 29:470鈥?82PubMedCentral CrossRef PubMed
    10.Fernandez-Seara MA, Wehrli SL, Wehrli FW (2003) Multipoint mapping for imaging of semi-solid materials. J Magn Reson 160:144鈥?50CrossRef PubMed
    11.Cao H, Ackerman JL, Hrovat MI, Graham L, Glimcher MJ, Wu Y (2008) Quantitative bone matrix density measurement by water- and fat-suppressed proton projection MRI (WASPI) with polymer calibration phantoms. Magn Reson Med 60:1433鈥?443PubMedCentral CrossRef PubMed
    12.Gatehouse PD, Bydder GM (2003) Magnetic resonance imaging of short T2 components in tissue. Clin Radiol 58:1鈥?9CrossRef PubMed
    13.Bergin CJ, Pauly JM, Macovski A (1991) Lung parenchyma: projection reconstruction MR imaging. Radiology 179:777鈥?81CrossRef PubMed
    14.Bergin CJ, Noll DC, Pauly JM, Glover GH, Macovski A (1992) MR imaging of lung parenchyma: a solution to susceptibility. Radiology 183:673鈥?76CrossRef PubMed
    15.Gold GE, Pauly JM, Macovski A, Herfkens RJ (1995) MR spectroscopic imaging of collagen: tendons and knee menisci. Magn Reson Med 34:647鈥?54CrossRef PubMed
    16.Reichert IL, Robson MD, Gatehouse PD et al (2005) Magnetic resonance imaging of cortical bone with ultrashort TE pulse sequences. Magn Reson Imaging 23:611鈥?18CrossRef PubMed
    17.Gao S, Du J, Wang F, Bao S (2013) Magnetic resonance ultrashort echo time spin-echo imaging of the deepest layers of articular cartilage. Sci China Life Sci 56:672鈥?74CrossRef PubMed
    18.Du J, Hamilton G, Takahashi A, Bydder M, Chung CB (2007) Ultrashort echo time spectroscopic imaging (UTESI) of cortical bone. Magn Reson Med 58:1001鈥?009CrossRef PubMed
    19.Rahmer J, Blume U, Bornert P (2007) Selective 3D ultrashort TE imaging: comparison of 鈥渄ual-echo鈥?acquisition and magnetization preparation for improving short-T 2 contrast. MAGMA 20:83鈥?2CrossRef PubMed
    20.Ma L, Meng Q, Chen Y, Zhang Z, Sun H, Deng D (2013) Preliminary use of a double-echo pulse sequence with 3D ultrashort echo time in the MRI of bones and joints. Exp Ther Med 5:1471鈥?475PubMedCentral PubMed
    21.Omoumi P, Bae WC, Du J et al (2012) Meniscal calcifications: morphologic and quantitative evaluation by using 2D inversion-recovery ultrashort echo time and 3D ultrashort echo time 3.0-T MR imaging techniques: feasibility study. Radiology 264:260鈥?68PubMedCentral CrossRef PubMed
    22.Bae WC, Dwek JR, Znamirowski R et al (2010) Ultrashort echo time MR imaging of osteochondral junction of the knee at 3 T: identification of anatomic structures contributing to signal intensity. Radiology 254:837鈥?45PubMedCentral CrossRef PubMed
    23.Dikkers R, Willems TP, Piers LH et al (2008) Coronary revascularization treatment based on dual-source computed tomography. Eur Radiol 18:1800鈥?808PubMedCentral CrossRef PubMed
    24.Eley KA, Sheerin F, Taylor N, Watt-Smith SR, Golding SJ (2013) Identification of normal cranial sutures in infants on routine magnetic resonance imaging. J Craniofac Surg 24:317鈥?20CrossRef PubMed
    25.Eley KA, Watt-Smith SR, Sheerin F, Golding SJ (2014) 鈥淏lack Bone鈥?MRI: a potential alternative to CT with three-dimensional reconstruction of the craniofacial skeleton in the diagnosis of craniosynostosis. Eur Radiol 24:2417鈥?426CrossRef PubMed
    26.Du J (2012) Qualitative and quantitative ultrashort echo time (UTE) MRI of cortical bone. Proc Int Soc Magn Reson Med 20:1鈥?3
    27.Tyler DJ, Robson MD, Henkelman RM, Young IR, Bydder GM (2007) Magnetic resonance imaging with ultrashort TE (UTE) PULSE sequences: technical considerations. J Magn Reson Imaging 25:279鈥?89CrossRef PubMed
    28.Robson MD, Bydder GM (2006) Clinical ultrashort echo time imaging of bone and other connective tissues. NMR Biomed 19:765鈥?80CrossRef PubMed
    29.Bae WC, Chen PC, Chung CB, Masuda K, D'Lima D, Du J (2012) Quantitative ultrashort echo time (UTE) MRI of human cortical bone: correlation with porosity and biomechanical properties. J Bone Miner Res 27:848鈥?57PubMedCentral CrossRef PubMed
    30.Biswas R, Bae W, Diaz E et al (2012) Ultrashort echo time (UTE) imaging with bi-component analysis: bound and free water evaluation of bovine cortical bone subject to sequential drying. Bone 50:749鈥?55PubMedCentral CrossRef PubMed
    31.Techawiboonwong A, Song HK, Leonard MB, Wehrli FW (2008) Cortical bone water: in vivo quantification with ultrashort echo-time MR imaging. Radiology 248:824鈥?33PubMedCentral CrossRef PubMed
    32.Rad HS, Lam SC, Magland JF et al (2011) Quantifying cortical bone water in vivo by three-dimensional ultra-short echo-time MRI. NMR Biomed 24:855鈥?64PubMedCentral CrossRef PubMed
    33.Geiger D, Bae WC, Statum S, Du J, Chung CB (2014) Quantitative 3D ultrashort time-to-echo (UTE) MRI and micro-CT (muCT) evaluation of the temporomandibular joint (TMJ) condylar morphology. Skelet Radiol 43:19鈥?5CrossRef
    34.Du J, Hermida JC, Diaz E et al (2012) Assessment of cortical bone with clinical and ultrashort echo time sequences. Magn Reson Med. doi:10.鈥?002/鈥媘rm.鈥?4497
    35.Kim DS, Kong MH, Jang SY et al (2013) The usefulness of brain magnetic resonance imaging with mild head injury and the negative findings of brain computed tomography. J Korean Neurosurg Soc 54:100鈥?06PubMedCentral CrossRef PubMed
  • 作者单位:Hao Wu (1)
    Yu-min Zhong (1)
    Quan-min Nie (2)
    Wei-bo Chen (3)
    Lie-mei Guo (2)
    Xi Yang (2)
    Hong Zhang (1)
    Yi Lin (1)
    Jian-rong Xu (4)
    Yong-ming Dai (3)
    Ming Zhu (1)

    1. Department of Radiology, Shanghai Children鈥檚 Medical Center, Shanghai Jiao Tong University School of Medicine, No. 1678, Dongfang Road, Shanghai, 200127, China
    2. Department of Neurosurgery Ren Ji Hospital, Shanghai Jiao Tong University School of Medicine, No. 1630, Dongfang Road, Shanghai, 200127, China
    3. Philips Healthcare, Shanghai, China
    4. Department of Radiology, Ren Ji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
  • 刊物类别:Medicine
  • 刊物主题:Medicine & Public Health
    Imaging and Radiology
    Diagnostic Radiology
    Interventional Radiology
    Neuroradiology
    Ultrasound
    Internal Medicine
  • 出版者:Springer Berlin / Heidelberg
  • ISSN:1432-1084
文摘
Objectives To investigate the feasibility of ultrashort echo time (UTE) magnetic resonance imaging (MRI) for the diagnosis of skull fractures.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083