In vitro artefact assessment of a new MR-compatible microwave antenna and a standard MR-compatible radiofrequency ablation electrode for tumour ablation
详细信息    查看全文
  • 作者:Rüdiger Hoffmann ; Hansjörg Rempp ; Frank Eibofner…
  • 关键词:Microwave ablation ; Magnetic resonance imaging ; Magnetic resonance imaging ; interventional ; Tumour ablation ; Artefact
  • 刊名:European Radiology
  • 出版年:2016
  • 出版时间:March 2016
  • 年:2016
  • 卷:26
  • 期:3
  • 页码:771-779
  • 全文大小:950 KB
  • 参考文献:1.Cance WG, Stewart AK, Menck HR (2000) The National Cancer Data Base Report on treatment patterns for hepatocellular carcinomas: improved survival of surgically resected patients, 1985–1996. Cancer 88:912–920CrossRef PubMed
    2.N’Kontchou G, Mahamoudi A, Aout M et al (2009) Radiofrequency ablation of hepatocellular carcinoma: long-term results and prognostic factors in 235 Western patients with cirrhosis. Hepatology 50:1475–1483CrossRef PubMed
    3.Solbiati L, Ahmed M, Cova L, Ierace T, Brioschi M, Goldberg SN (2012) Small liver colorectal metastases treated with percutaneous radiofrequency ablation: local response rate and long-term survival with up to 10-year follow-up. Radiology 265:958–968CrossRef PubMed
    4.Gillams AR, Lees WR (2009) Five-year survival in 309 patients with colorectal liver metastases treated with radiofrequency ablation. Eur Radiol 19:1206–1213CrossRef PubMed
    5.Gillams A, Goldberg N, Ahmed M et al (2015) Thermal ablation of colorectal liver metastases: a position paper by an international panel of ablation experts, the interventional oncology sans frontieres meeting 2013. Eur Radiol. 2015 May 22. [Epub ahead of print] PubMedPMID: 25994193
    6.de Jong KP, Wertenbroek MW (2011) Liver resection combined with local ablation: where are the limits? Dig Surg 28:127–133CrossRef PubMed
    7.Lubner MG, Brace CL, Hinshaw JL, Lee FT Jr (2010) Microwave tumor ablation: mechanism of action, clinical results, and devices. J Vasc Interv Radiol 21:S192–203PubMedCentral CrossRef PubMed
    8.Fan W, Li X, Zhang L, Jiang H, Zhang J (2012) Comparison of microwave ablation and multipolar radiofrequency ablation in vivo using two internally cooled probes. AJR Am J Roentgenol 198:W46–50CrossRef PubMed
    9.Laeseke PF, Lee FT Jr, Sampson LA, van der Weide DW, Brace CL (2009) Microwave ablation versus radiofrequency ablation in the kidney: high-power triaxial antennas create larger ablation zones than similarly sized internally cooled electrodes. J Vasc Interv Radiol 20:1224–1229PubMedCentral CrossRef PubMed
    10.Wright AS, Sampson LA, Warner TF, Mahvi DM, Lee FT Jr (2005) Radiofrequency versus microwave ablation in a hepatic porcine model. Radiology 236:132–139CrossRef PubMed
    11.Bhardwaj N, Dormer J, Ahmad F et al (2011) Microwave ablation of the liver: a description of lesion evolution over time and an investigation of the heat sink effect. Pathology 43:725–731CrossRef PubMed
    12.Kang TW, Lim HK, Lee MW, Kim YS, Choi D, Rhim H (2014) Perivascular versus nonperivascular small HCC treated with percutaneous RF ablation: retrospective comparison of long-term therapeutic outcomes. Radiology 270:888–899CrossRef PubMed
    13.Brace CL, Hinshaw JL, Laeseke PF, Sampson LA, Lee FT Jr (2009) Pulmonary thermal ablation: comparison of radiofrequency and microwave devices by using gross pathologic and CT findings in a swine model. Radiology 251:705–711PubMedCentral CrossRef PubMed
    14.Goldberg SN, Gazelle GS, Compton CC, Mueller PR, Tanabe KK (2000) Treatment of intrahepatic malignancy with radiofrequency ablation: radiologic-pathologic correlation. Cancer 88:2452–2463CrossRef PubMed
    15.Leyendecker JR, Dodd GD 3rd, Halff GA et al (2002) Sonographically observed echogenic response during intraoperative radiofrequency ablation of cirrhotic livers: pathologic correlation. AJR Am J Roentgenol 178:1147–1151CrossRef PubMed
    16.Rempp H, Loh H, Hoffmann R et al (2014) Liver lesion conspicuity during real-time MR-guided radiofrequency applicator placement using spoiled gradient echo and balanced steady-state free precession imaging. J Magn Reson Imaging 40:432–439CrossRef PubMed
    17.Terraz S, Cernicanu A, Lepetit-Coiffe M et al (2010) Radiofrequency ablation of small liver malignancies under magnetic resonance guidance: progress in targeting and preliminary observations with temperature monitoring. Eur Radiol 20:886–897CrossRef PubMed
    18.Clasen S, Rempp H, Hoffmann R, Graf H, Pereira PL, Claussen CD (2014) Image-guided radiofrequency ablation of hepatocellular carcinoma (HCC): is MR guidance more effective than CT guidance? Eur J Radiol 83:111–116CrossRef PubMed
    19.Hoffmann R, Thomas C, Rempp H et al (2012) Performing MR-guided biopsies in clinical routine: factors that influence accuracy and procedure time. Eur Radiol 22:663–671CrossRef PubMed
    20.Hoffmann R, Rempp H, Erhard L et al (2013) Comparison of four microwave ablation devices: an experimental study in ex vivo bovine liver. Radiology 268:89–97CrossRef PubMed
    21.(ASTM) ASfTaM (2001) Designation: F 2119-01 - standard test method for evaluation of MR image artifacts from passive implants
    22.Lubner MG, Hinshaw JL, Andreano A, Sampson L, Lee FT Jr, Brace CL (2012) High-powered microwave ablation with a small-gauge, gas-cooled antenna: initial ex vivo and in vivo results. J Vasc Interv Radiol 23:405–411PubMedCentral CrossRef PubMed
    23.Liu H, Hall WA, Martin AJ, Truwit CL (2001) Biopsy needle tip artifact in MR-guided neurosurgery. J Magn Reson Imaging 13:16–22CrossRef PubMed
    24.Aube C, Schmidt D, Brieger J et al (2004) Magnetic resonance imaging characteristics of six radiofrequency electrodes in a phantom study. J Vasc Interv Radiol 15:385–392CrossRef PubMed
    25.Thomas C, Wojtczyk H, Rempp H et al (2011) Carbon fibre and nitinol needles for MRI-guided interventions: first in vitro and in vivo application. Eur J Radiol 79:353–358CrossRef PubMed
    26.Thomas C, Springer F, Rothke M et al (2010) In vitro assessment of needle artifacts with an interactive three-dimensional MR fluoroscopy system. J Vasc Interv Radiol 21:375–380CrossRef PubMed
    27.Penzkofer T, Peykan N, Schmidt K, Krombach G, Kuhl CK (2013) How MRI compatible is “MRI compatible”? A systematic comparison of artifacts caused by biopsy needles at 3.0 and 1.5 T. Cardiovasc Intervent Radiol 36:1646–1657CrossRef PubMed
    28.Wonneberger U, Schnackenburg B, Streitparth F, Walter T, Rump J, Teichgraber UK (2010) Evaluation of magnetic resonance imaging-compatible needles and interactive sequences for musculoskeletal interventions using an open high-field magnetic resonance imaging scanner. Cardiovasc Intervent Radiol 33:346–351CrossRef PubMed
    29.Montorsi F, Guazzoni G, Colombo R, Galli L, Bergamaschi F, Rigatti P (1992) Transrectal microwave hyperthermia for advanced prostate cancer: long-term clinical results. J Urol 148:342–345PubMed
  • 作者单位:Rüdiger Hoffmann (1)
    Hansjörg Rempp (1)
    Frank Eibofner (1)
    David-Emanuel Keßler (1)
    Gunnar Blumenstock (2)
    Jakob Weiß (1)
    Philippe L. Pereira (3)
    Konstantin Nikolaou (1)
    Stephan Clasen (1)

    1. Department of Diagnostic and Interventional Radiology, Eberhard Karls University, Hoppe-Seyler-Strasse 3, 72076, Tübingen, Germany
    2. Department of Clinical Epidemiology and Applied Biometry, Eberhard Karls University, Silcherstr. 5, 72076, Tübingen, Germany
    3. Department of Radiology, Minimally Invasive Therapies, and Nuclear Medicine, SLK-Kliniken Heilbronn GmbH, Am Gesundbrunnen 20-26, 74078, Heilbronn, Germany
  • 刊物类别:Medicine
  • 刊物主题:Medicine & Public Health
    Imaging and Radiology
    Diagnostic Radiology
    Interventional Radiology
    Neuroradiology
    Ultrasound
    Internal Medicine
  • 出版者:Springer Berlin / Heidelberg
  • ISSN:1432-1084
文摘
Objective To evaluate and compare artefact configuration and diameters in a magnetic resonance (MR)-compatible prototype microwave (MW) applicator and a standard MR-compatible radiofrequency (RF) applicator for MR-guided tumour ablation.