Improvement in performance of a hyoscine butylbromide potentiometric sensor using a new nanocomposite carbon paste: a comparison study with polymeric membrane sensor
详细信息    查看全文
  • 作者:Abbas Afkhami (1)
    Ali Shirzadmehr (1)
    Tayyebeh Madrakian (1)
  • 关键词:Hyoscine butylbromide ; Potentiometric sensor ; TiO2 nanoparticles ; MWCNTs
  • 刊名:Ionics
  • 出版年:2014
  • 出版时间:August 2014
  • 年:2014
  • 卷:20
  • 期:8
  • 页码:1145-1154
  • 全文大小:497 KB
  • 参考文献:1. Klavarioti M, Mantzavinos D, Kassinos D (2009) Removal of residual pharmaceuticals from aqueous systems by advanced oxidation processes. Environ Int 35:402鈥?17 CrossRef
    2. Rajendra N, Gupta VK, Bachheti N (2007) Fullerene-C60-modified electrode as a sensitive voltammetric sensor for detection of nandrolone鈥攁n anabolic steroid used in doping. Anal Chim Acta 597:82鈥?9 CrossRef
    3. Goyal RN, Gupta VK, Chatterjee S (2009) Fullerene-C60-modified edge plane pyrolytic graphite electrode for the determination of dexamethasone in pharmaceutical formulations and human biological fluids. Biosens Bioelectron 24:1649鈥?654 CrossRef
    4. Goyal RN, Gupta VK, Chatterjee S (2009) A sensitive voltammetric sensor for determination of synthetic corticosteroid triamcinolone, abused for doping. Biosens Bioelectron 24:3562鈥?568 CrossRef
    5. Gupta VK, Jain R, Radhapyari K, Jadon N, Agarwal S (2011) Voltammetric techniques for the assay of pharmaceuticals鈥攁 review. Anal Biochem 408:179鈥?96 CrossRef
    6. Beitollahi H, Mohadesi A, Khalilizadeh Mahani S, Karimi-Maleh H, Akbari A (2012) New voltammetric strategy for simultaneous determination of norepinephrine, acetaminophen, and folic acid using a 5-amino-3鈥?4鈥?dimethoxy-biphenyl-2-ol/carbon nanotube paste electrode. Ionics 18:703鈥?10 CrossRef
    7. Madrakian T, Ahmadi M, Afkhami A, Soleimani M (2013) Selective solid-phase extraction of naproxen drug from human urine samples using molecularly imprinted polymer-coated magnetic multi-walled carbon nanotubes prior to its spectrofluorometric determination. Analyst 138:4542鈥?549 CrossRef
    8. Crossland J (ed) (1980) Lewis鈥檚 pharmacology, 5th edn. Churchill Livingstone, New York, pp 224鈥?34
    9. Erk N, Onur F (1996) Spectrophotometric simultaneous determination of analgin and hyoscine N-butyl bromide in sugar-coated tablets. Anal Lett 29:369鈥?80 CrossRef
    10. Toral MI, Munoz MA, Orellana SL (2005) Simultaneous determination of / N-butylscopolamine and oxazepam in pharmaceutical formulations by first-order digital derivative spectrophotometry. J AOAC Int 88:1173鈥?178
    11. Mahrous MS, Daabees HG, Beltagy YA (1992) New sensitive method for the analysis of some non UV absorbing quaternised compounds. Spectrosc Lett 25:389鈥?00 CrossRef
    12. Gouda AA, El-Shafey Z, Hossny N, El-Azzazy R (2008) Spectrophotometric determination of hyoscine butylbromide and famciclovir in pure form and in pharmaceutical formulations. Spectrochim Acta A 70:785鈥?92 CrossRef
    13. Bayne WF, Tao FT, Crisologo N (1975) Submicrogram assay for scopolamine in plasma and urine. J Pharm Sci 64:288鈥?91 CrossRef
    14. Mandal S, Naqvi AA, Thakur RS (1991) Analysis of some tropane alkaloids in plants by mixed-column high-performance liquid chromatography. J Chromatogr A 547:468鈥?71 CrossRef
    15. Cherkaoui S, Mateus L, Christen P, Veuthey JL (1999) Nonaqueous versus aqueous capillary electrophoresis for the dosage of / N-butylscopolamine in various pharmaceutical formulations. J Pharm Biomed 21:165鈥?74 CrossRef
    16. Bobacka J, Ivaska A, Lewenstam A (2008) Potentiometric Ion Sensors. Chem Rev 108:329鈥?51 CrossRef
    17. S藝vancara I, Vytr藝as K, Kalcher K, Walcarius A, Wang J (2009) Carbon paste electrodes in facts, numbers, and notes: a review on the occasion of the 50-years jubilee of carbon paste in electrochemistry and electroanalysis. Electroanalysis 21:7鈥?8 CrossRef
    18. Abbastabar-Ahangar H, Shirzadmehr A, Marjani K, Khoshsafar H, Chaloosi M, Mohammadi L (2009) Ion-selective carbon paste electrode based on new tripodal ligand for determination of cadmium (II). J Inc. Phenom Macrocycl Chem 63:287鈥?93 CrossRef
    19. Ganjali MR, Khoshsafar H, Shirzadmehr A, Javanbakht M, Faridbod F (2009) Improvement of carbon paste ion selective electrode response by using room temperature ionic liquids (RTILs) and multi-walled carbon nanotubes (MWCNTs). Int J Electrochem Sci 4:435鈥?43
    20. Ganjali MR, Khoshsafar H, Faridbod F, Shirzadmehr A, Javanbakht M, Norouzi P (2009) Room temperature ionic liquids (RTILs) and multiwalled carbon nanotubes (MWCNTs) as modifiers for improvement of carbon paste ion selective electrode response; a comparison study with PVC membrane. Electroanalysis 21:2175鈥?178 CrossRef
    21. Gupta VK, Agarwal S, Singhal B (2011) Potentiometric assay of antipsychotic drug (ziprasidone hydrochloride) in pharmaceuticals, serum and urine. Int J Electrochem Sci 6:3036鈥?056
    22. Afkhami A, Madrakian T, Shirzadmehr A, Bagheri H, Tabatabaee M (2012) A selective sensor for nanolevel detection of lead (II) in hazardous wastes using ionic-liquid/Schiff base/MWCNTs/nanosilica as a highly sensitive composite. Ionics 18:881鈥?89 CrossRef
    23. Afkhami A, Madrakian T, Shirzadmehr A, Tabatabaee M, Bagheri H (2012) New Schiff base-carbon nanotube鈥搉anosilica鈥搃onic liquid as a high performance sensing material of a potentiometric sensor for nanomolar determination of cerium(III) ions. Sensors Actuators B 174:237鈥?44 CrossRef
    24. Mashhadizadeh MH, Eskandari K, Foroumadi A, Shafiee A (2008) Self-assembled mercapto-compound-gold-nanoparticle-modified carbon paste electrode for potentiometric determination of cadmium(II). Electroanalysis 20:1891鈥?896 CrossRef
    25. Mashhadizadeh MH, Khani H (2010) Sol-gel-Au nano-particle modified carbon paste electrode for potentiometric determination of sub ppb level of Al(III). Anal Methods 2:24鈥?1 CrossRef
    26. Mashhadizadeh MH, Yousefi, NozadGolikand A (2012) A nickel hexacyanoferrate and poly(1-naphthol) hybrid film modified electrode used in the selective electroanalysis of dopamine. Electrochim Acta 59:321鈥?28 CrossRef
    27. Bagheri H, Afkhami A, Saber-Tehrani M, Shirzadmehr A, Husain SW, Khoshsafar H, Tabatabaee M (2012) Novel sensor fabrication for the determination of nanomolar concentrations of Ce3+ in aqueous solutions. Anal Methods 4:1753鈥?758 CrossRef
    28. Afkhami A, Bagheri H, Shirzadmehr A, Khoshsafar H, Hashemi P (2012) A potentiometric sensor for Cd2+ based on carbon nanotube paste electrode constructed from room temperature ionic liquid, ionophore and silica Nanoparticles. Electroanalysis 24:2176鈥?185 CrossRef
    29. Bagheri H, Afkhami A, Shirzadmehr A, Khoshsafar H, Khoshsafar H, Ghaedi H (2013) Novel potentiometric sensor for the determination of Cd2+ based on a new nano-composite. Int J Environ Anal Chem 93:578鈥?91 CrossRef
    30. Gupta VK, Singh AK, Gupta B (2007) Schiff bases as cadmium (II) selective ionophores in polymeric membrane electrodes. Anal Chim Acta 583:340鈥?48 CrossRef
    31. Gupta VK, Singh AK, Al Khayat M, Gupta B (2007) Neutral carriers based polymeric membrane electrodes for selective determination of mercury (II). Anal Chim Acta 590:81鈥?0 CrossRef
    32. Nezamzadeh-Ejhieh A, Esmaeilian A (2012) Application of surfactant modified zeolite carbon paste electrode (SMZ-CPE) towards potentiometric determination of sulfate. Microporous Mesoporous Mater 147:302鈥?09 CrossRef
    33. Wo鈥檢nica E, W贸jcik MM, Wojciechowski M, Mieczkowski J, Bulska E, Maksymiuk K, Michalska A (2012) Dithizone modified gold nanoparticles films for potentiometric sensing. Anal Chem 84:4437鈥?442 CrossRef
    34. Yuan X, Chai Y, Yuan R, Zhao Q (2013) Improved potentiometric response of solid-contact lanthanum (III) selective electrode. Anal Chim Acta 779:35鈥?0 CrossRef
    35. Burd C, Chen X, Narayanan R, El-Sayed MA (2005) Chemistry and properties of nanocrystals of different shapes. Chem Rev 105:1025鈥?102 CrossRef
    36. O鈥橰egan B, Gratzel M (1991) A low-cost, high-efficiency solar cell based on dye-sensitized colloidal TiO2 films. Nature 353:737鈥?40 CrossRef
    37. Macak JM, Barczuk PJ, Tsuchiya H, Nowakowska MZ, Ghicov A, Chojak M, Bauer S, Virtanen S, Kulesza PJ, Schmuki P (2005) Self-organized nanotubular TiO2 matrix as support for dispersed Pt/Ru nanoparticles: enhancement of the electrocatalytic oxidation of methanol. Electrochem Commun 7:1417鈥?422 CrossRef
    38. He R, Zhao L, Liu Y, Zhang N, Cheng B, He Z, Cai B, Li S, Liu W, Guo S, Chen Y, Xiong B, Zhao XZ (2013) Biocompatible TiO2 nanoparticle-based cell immunoassay for circulating tumor cells capture and identification from cancer patients. Biomed Microdevices 15:617鈥?26 CrossRef
    39. El-Saharty YS, Metwaly FH, Refaat M, El-Khateeb SZ (2007) Development of membrane electrodes for the selective determination of hyoscine butylbromide. Talanta 72:675鈥?81 CrossRef
    40. Valentini F, Amine A, Orlandocci S, Terranova ML, Palleschi G (2003) Carbon nanotube purification: preparation and characterization of carbon nanotube paste electrodes. Anal Chem 75:5413鈥?421 CrossRef
    41. Madrakian T, Afkhami A, Ahmadi M, Bagheri H (2011) Removal of some cationic dyes from aqueous solutions using magnetic-modified multi-walled carbon nanotubes. J Hazard Mater 196:109鈥?14 CrossRef
    42. Bhat SV, Ijeri SV, Srivastava AK (2004) Coated wire lead (II) selective potentiometric sensor based on 4-tert-butylcalix[6]arene. Sensors Actuators B 99:98鈥?05 CrossRef
    43. Afkhami A, Bagheri H, Khoshsafar H, Saber-Tehrani M, Tabatabaee M, Shirzadmehr A (2012) Simultaneous trace-levels determination of Hg(II) and Pb(II) ions in various samples using a modified carbon paste electrode based on multi-walled carbon nanotubes and a new synthesized Schiff base. Anal Chim Acta 746:98鈥?06 CrossRef
    44. Karimi-Maleh H, Ensafi AA, Beitollahi H, Nasiri V, Khalilzadeh MA, Biparva P (2012) Electrocatalytic determination of sulfite using a modified carbon nanotubes paste electrode: application for determination of sulfite in real samples. Ionics 18:687鈥?94 CrossRef
    45. Ensafi AA, Izadi M, Karimi-Maleh H (2013) Sensitive voltammetric determination of diclofenac using room-temperature ionic liquid-modified carbon nanotubes paste electrode. Ionics 19:137鈥?44 CrossRef
    46. Bagheri H, Afkhami A, Khoshsafar H, Rezaei M, Shirzadmehr A (2013) Simultaneous electrochemical determination of heavy metals using atriphenylphosphine/MWCNTs composite carbon ionic liquid electrode. Sensors Actuators B 186:451鈥?60 CrossRef
    47. Li Q, Wang Y, Luo G (2000) Voltammetric separation of dopamine and ascorbic acid with graphite electrodes modified with ultrafine TiO2. Mater Sci Eng C 11:71鈥?4 CrossRef
    48. Li G, Qu J, Zhang X, Ge J (2006) Electrochemically assisted photocatalytic degradation of Acid Orange 7 with / 尾-PbO2 electrodes modified by TiO2. Water Res 40:213鈥?20 CrossRef
    49. Lunsford SK, Choi H, Stinson J, Yeary A, Dionysiou DD (2007) Voltammetric determination of catechol using a sonogel carbon electrode modified with nanostructured titanium dioxide. Talanta 73:172鈥?77 CrossRef
    50. Lo PH, Kumar SA, Chen SM (2008) Amperometric determination of H2O2 at nano-TiO2/DNA/thionin nanocomposite modified electrode. Colloids Surf B 66:266鈥?73 CrossRef
    51. Raoof JB, Ojani R, Baghayeri M (2011) Sensitive voltammetric determination of captopril using a carbon paste electrode modified with nano-TiO2/ferrocene carboxylic acid. Chin J Catal 32:1685鈥?692 CrossRef
    52. Gupta VK, Chandra S, Mangla R (2002) Dicyclohexano-18-crown-6 as active material in PVC matrix membrane for the fabrication of cadmium selective potentiometric sensor. Electrochim Acta 47:1579鈥?586 CrossRef
    53. Gupta VK, Prasad R, Kumar A (2003) Preparation of ethambutol鈥揷opper(II) complex and fabrication of PVC based membrane potentiometric sensor for copper. Talanta 60:149鈥?60 CrossRef
    54. Gupta VK, Chandra S, Lang H (2005) A highly selective mercury electrode based on a diamine donor ligand. Talanta 66:575鈥?80 CrossRef
    55. Gupta VK, Jain AK, Kumar P, Agarwal S, Maheshwari G (2006) Chromium(III)-selective sensor based on tri- / o-thymotide in PVC matrix. Sensors Actuators B 113:182鈥?86 CrossRef
    56. Gupta VK, Jain AK, Maheshwari G, Lang H, Ishtaiwi Z (2006) Copper(II)-selective potentiometric sensors based on porphyrins in PVC matrix. Sensors Actuators B 117:99鈥?06 CrossRef
    57. Gupta VK, Jain AK, Kumar P (2006) PVC-based membranes of N, N鈥?dibenzyl-1,4,10,13-tetraoxa-7,16-diazacyclooctadecane as Pb(II)-selective sensor. Sensors Actuators B 120:259鈥?65 CrossRef
    58. Gupta VK, Singh AK, Mehtab S, Gupta B (2006) Cobalt(II)-selective PVC membrane based on a Schiff base complex of N, N鈥?bis(salicylidene)-3,4-diaminotoluene. Anal Chim Acta 566:5鈥?0 CrossRef
    59. Ensafi AA, Allafchian AR (2008) Novel and selective potentiometric membrane sensor for amiloride determination in pharmaceutical compounds and urine. J Pharm Biomed 47:802鈥?06 CrossRef
    60. Mostafa GAE, Al-Majed A (2008) Characteristics of new composite- and classical potentiometric sensors for the determination of pioglitazone in some pharmaceutical formulations. J Pharm Biomed 48:57鈥?1 CrossRef
    61. Abu-Shawish HM, Dalou AA, Abu Ghalwa N, Khraish GI, Hammad J, Basheer AH (2014) Determination of pethidine hydrochloride using potentiometric coated graphite and carbon paste electrodes. Drug Test Anal. doi:10.1002/dta.287
    62. Abu-Shawish HM, Abu Ghalwa N, Saadeh SM, El Harazeen H (2013) Development of novel potentiometric sensors for determination of tartrazine dye concentration in foodstuff products. Food Chem 138:126鈥?32 CrossRef
    63. Umezawa Y, Umezawa K, Sato H (1995) Selectivity coefficients for ion-selective electrodes: recommended methods for reporting / K A,聽B pot values (Technical Report). Pure Appl Chem 67:507鈥?18 CrossRef
    64. Li B, Zhang Z, You X, Lu T, Yin G (1988) PVC membrane electrodes of anisodamine, / N-butylscopolamine and homatropine. Analyst 113:57鈥?0 CrossRef
    65. Wassel AA, Abu-Talib NF (2010) Sensors membrane electrodes for sensitive determination of / hyoscine butylbromide in pharmaceutical formulation and in human plasma. Sens Electroanalysis 5:229鈥?42
  • 作者单位:Abbas Afkhami (1)
    Ali Shirzadmehr (1)
    Tayyebeh Madrakian (1)

    1. Faculty of Chemistry, Bu-Ali Sina University, Hamedan, Iran
  • ISSN:1862-0760
文摘
Multiwalled carbon nanotubes and TiO2 nanoparticles were used for the improvement of a hyoscine butylbromide (HYBB) potentiometric carbon paste electrode response. The electrode was based on the ammonium reineckate-hyoscine ion association complex as an ion-exchange site dissolved in 2-nitrophenyloctyl ether as pasting liquid. The characteristics of the suggested potentiometric nanocomposite-modified HYBB carbon paste electrode in comparison with the PVC membrane sensor show better responses in terms of sensitivity, dynamic concentration range, detection limit, Nernstain slope, low potential drift, response time, lifetime, and mechanical stability. The electrode exhibits good selectivity for HYB ion with respect to a large number of cations. For investigation of the effects of carbon nanotubes and TiO2 nanoparticles on the conductivity property of the electrode surface, electrochemical impedance spectroscopy measurements were done. The prepared electrode was successfully applied to the determination of hyoscine butylbromide in pharmaceutical formulations and biological samples.