Voltammetric determination of ultratrace levels of cerium(III) using a carbon paste electrode modified with nano-sized cerium-imprinted polymer and multiwalled carbon nanotubes
详细信息    查看全文
  • 作者:Taher Alizadeh ; Mohammad Reza Ganjali ; Maede Akhoundian…
  • 关键词:Square wave voltammetry ; Ion imprinted polymer ; Nanomaterial ; Precipitation polymerization ; Scanning electron microscopy ; Zeta potential
  • 刊名:Microchimica Acta
  • 出版年:2016
  • 出版时间:March 2016
  • 年:2016
  • 卷:183
  • 期:3
  • 页码:1123-1130
  • 全文大小:1,438 KB
  • 参考文献:1.Wilson CL, Wilson DW (1962) 477 Comprehensive analytical chemistry, vol 1C. Elsevier, Amsterdam
    2.Fricker SP (2006) The therapeutic application of lanthanides. Chem Soc Rev 35:524–533CrossRef
    3.Rao CK, Reddy VK, Reddy TS (1994) Rapid and sensitive spectrophotometric determination of cerium (IV) with 2, 4-dihydroxy benzophenone benzoic hydrazone. Talanta 41:237–241CrossRef
    4.Gupta VK, Singh AK, Gupta B (2006) A cerium (III) selective polyvinyl chloride membrane sensor based on a schiff base complex of N, N-bis [2-(salicylideneamino) ethyl] ethane-1, 2-diamine. Anal Chim Acta 575:198–204CrossRef
    5.Osman AM, Hilhorst R, Laane C (2000) Chemiluminescent determination of Ce (IV) using cypridina luciferin analog. Anal Chim Acta 422:81–87CrossRef
    6.Akseli A, Rakicioğlu Y (1996) Fluorimetric trace determination of cerium (III) with sodium triphosphate. Talanta 43:1983–1988CrossRef
    7.Singh AK, Singh P (2010) Determination of cerium ion by polymeric membrane and coated graphite electrode based on novel pendant armed macrocycle. Anal Chim Acta 675:170–180CrossRef
    8.Afkhami A, Madrakian T, Shirzadmehr A, Tabatabaee M, Bagheri H (2012) New schiff base-carbon nanotube-nanosilica-ionic liquid as a high performance sensing material of a potentiometric sensor for nanomolar determination of cerium (III) ions. Sensors Actuators B Chem 174:237–244CrossRef
    9.Hamajima Y, Koba M, Endo K, Nakahara H (1985) Determination of lanthanoids in Japanese standard rocks by radiochemical neutron activation method. J Radioanal Nucl Chem 89:315–321CrossRef
    10.Wang J, Farias PA, Mahmoud JS (1985) Trace determination of lanthanum, cerium, and praseodymium based on adsorptive stripping voltammetry. Anal Chim Acta 171:215–223CrossRef
    11.Svancara I, Vytras K, Barek J, Zima J (2001) Carbon paste electrodes in modern electroanalysis. Crit Rev Anal Chem 31:311–345CrossRef
    12.Alizadeh T, Fard LA (2013) Synthesis of Cu2+-mediated nano-sized salbutamol-imprinted polymer and its use for indirect recognition of ultra-trace levels of salbutamol. Anal Chim Acta 769:100–107CrossRef
    13.Zhang X, Li C, Yan Y, Pan J, Xu P, Zhao X (2010) A Ce3+-imprinted functionalized potassium tetratitanate whisker sorbent prepared by surface molecularly imprinting technique for selective separation and determination of Ce3 +. Microchim Acta 169:289–296CrossRef
    14.Alizadeh T, Amjadi S (2011) Preparation of nano-sized Pb 2+ imprinted polymer and its application as the chemical interface of an electrochemical sensor for toxic lead determination in different real samples. J Hazard Mater 190:451–459CrossRef
    15.Alizadeh T, Ganjali MR, Nourozi P, Zare M, Hoseini M (2011) A carbon paste electrode impregnated with Cd 2+ imprinted polymer as a new and high selective electrochemical sensor for determination of ultra-trace Cd2+ in water samples. J Electroanal Chem 657:98–106CrossRef
    16.Alizadeh T, Ganjali MR, Zare M (2011) Application of an Hg 2+ selective imprinted polymer as a new modifying agent for the preparation of a novel highly selective and sensitive electrochemical sensor for the determination of ultratrace mercury ions. Anal Chim Acta 689:52–59CrossRef
    17.Garcia R, Pinel C, Madic C, Lemaire M (1998) Ionic imprinting effect in gadolinium/lanthanum separation. Tetrahedron Lett 39:8651–8654CrossRef
    18.Alizadeh T, Ganjali MR (2015) Alizadeh T (2015) competitive extraction of Gd(III) into a carbon paste electrode impregnated with a nano-sized Gd(III)-imprinted polymer as a new method for its indirect voltammetric determination. Microchim Acta 182:1205–1212CrossRef
    19.Jiajia GUO, Jibao CAI, Qingde SU (2009) Ion imprinted polymer particles of neodymium: synthesis, characterization and selective recognition. J Rare Earths 27:22–27CrossRef
    20.Shirvani-Arani S, Ahmadi SJ, Bahrami-Samani A, Ghannadi-Maragheh M (2008) Synthesis of nano-pore samarium (III)-imprinted polymer for preconcentrative separation of samarium ions from other lanthanide ions via solid phase extraction. Anal Chim Acta 623:82–88CrossRef
    21.Prasad K, Kala R, Rao TP, Naidu GRK (2006) Ion imprinted polymer based ion-selective electrode for the trace determination of dysprosium (III) ions. Anal Chim Acta 566:69–74CrossRef
    22.Kala R, Biju VM, Rao TP (2005) Synthesis, characterization, and analytical applications of erbium (III) ion imprinted polymer particles prepared via gamma-irradiation with different functional and crosslinking monomers. Anal Chim Acta 549:51–58CrossRef
    23.Alizadeh T, Amjadi S (2013) Synthesis of nano-sized Eu3+−imprintedpolymeranditsapplication for indirectvoltammetricdeterminationofeuropium. Talanta 106:431–439CrossRef
    24.Pan J, Zou X, Li C, Liu Y, Yan Y, Han J (2010) Synthesis and applications of Ce (III)-imprinted polymer based on attapulgite as the sacrificial support material for selective separation of cerium (III) ions. Microchim Acta 171:151–160CrossRef
    25.Sinha N, Ma J, Yeow JT (2006) Carbon nanotube-based sensors. J Nanosci Nanotechnol 6:573–590CrossRef
    26.Dam HA, Kim D (2009) Selective copper (II) sorption behavior of surface-imprinted core-shell-type polymethacrylate microspheres. Ind Eng Chem Res 48:5679–5685CrossRef
    27.Javanbakht M, Khoshsafar H, Ganjali MR, Norouzi P, Badei A, Hasheminasab A (2008) Stripping voltammetry of cerium (IIl) with a chemically modified carbon paste electrode containing functionalized nanoporous silica gel. Electroanalysis 20:203–206CrossRef
    28.Javanbakht M, Khoshsafar H, Reza Ganjali M, Norouzi P, Adib M (2009) Adsorptive stripping voltammetric determination of nanomolar concentration of cerium (III) at a carbon paste electrode modified by N′-[(2-hydroxyphenyl)methylidene]-2-furohydrazide. Electroanalysis 21:1605–1610CrossRef
    29.Li J, Liu S, Yan Z, Mao X, Gao P (2006) Adsorptive voltammetric studies on the cerium (III)-alizarin complexon complex at a carbon paste electrode. Microchim Acta 154:241–246CrossRef
    30.Prasad BB, Jauhari D (2015) Double-ion imprinted polymer@ magnetic nanoparticles modified screen printed carbon electrode for simultaneous analysis of cerium and gadolinium ions. Anal Chim Acta 875:83–91CrossRef
    31.Liu S, Li J, Zhang S, Zhao J (2005) Study on the adsorptive stripping voltammetric determination of trace cerium at a carbon paste electrode modified in situ with cetyltrimethylammonium bromide. Appl Surf Sci 252:2078–2084CrossRef
  • 作者单位:Taher Alizadeh (1)
    Mohammad Reza Ganjali (1)
    Maede Akhoundian (1)
    Parviz Norouzi (1)

    1. Department of Analytical Chemistry, Faculty of Chemistry, University College of Science, University of Tehran, P.O. Box 14155-6455, Tehran, Iran
  • 刊物类别:Chemistry and Materials Science
  • 刊物主题:Chemistry
    Analytical Chemistry
    Inorganic Chemistry
    Physical Chemistry
    Characterization and Evaluation Materials
    Monitoring, Environmental Analysis and Environmental Ecotoxicology
  • 出版者:Springer Wien
  • ISSN:1436-5073
文摘
A carbon paste electrode was modified with a Ce(III)-imprinted polymer (Ce-IP) and used for voltammetric determination of Ce(III) ions in real water samples. Precipitation polymerization was used for synthesis of the nano-sized Ce-IP from vinylpyridine and methacrylic acid (acting as the complexing ligands and functional monomers), divinylbenzene (cross-linker) and AIBN as the radical starter. The Ce-IP was characterized by scanning electron microscopy and zeta potentials. A carbon paste electrode (CPE) was then impregnated with the Ce-IP and used for the extraction and subsequent determination of Ce(III). Oxidative square wave voltammetry showed the electrode to give a significantly better response than an electrode modified with the non-imprinted polymer. The addition of multiwalled carbon nanotubes to the Ce-IP-modified electrode further improves the signal, thereby increasing the sensitivity of the method. The effects of electrode composition, extraction pH value, volume and time were optimized. The electrode, if operated at a voltage of 1.05 V (vs. Ag/AgCl), displays a linear response to Ce(III) in the 1.0 μM to 25 pM concentration range, and the detection limit is 10 pM (at an S/N ratio of 3). The relative standard deviation of 5 separate determinations is 3.1 %. The method was successfully applied to the determination of Ce(III) in the spiked samples of drinking water and sea water.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700