Influences of different vasopressors on stroke volume variation and pulse pressure variation
详细信息    查看全文
  • 作者:Ran Kong ; Yi Liu ; Weidong Mi ; Qiang Fu
  • 关键词:Phenylephrine ; Dopamine ; Ephedrine ; Pulse pressure variation ; Stroke volume variation
  • 刊名:Journal of Clinical Monitoring and Computing
  • 出版年:2016
  • 出版时间:February 2016
  • 年:2016
  • 卷:30
  • 期:1
  • 页码:81-86
  • 全文大小:348 KB
  • 参考文献:1.Michard F. Changes in arterial pressure during mechanical ventilation. Anesthesiology. 2005;103:419–28.CrossRef PubMed
    2.Dunki-Jacobs EM, Philips P, Scoqqins CR, McMasters KM, Martin RC 2nd. Stroke volume variation in hepatic resection: a replacement for standard central venous pressure monitoring. Ann Surg Oncol. 2014;21:473–8.CrossRef PubMed
    3.Kramer A, Zygun D, Hawes H, Easton P, Ferland A. Pulse pressure variation predicts fluid responsiveness following coronary artery bypass surgery. Chest. 2004;126:1563–8.CrossRef PubMed
    4.Renner J, Cavus E, Meybohm P, Tonner P, Steinfath M, Scholz J, Lutter G, Bein B. Stroke volume variation during hemorrhage and after fluid loading: impact of different tidal volumes. Acta Anaesthesiol Scand. 2007;51(5):538–44.CrossRef PubMed
    5.Kim HK, Pinsky MR. Effect of tidal volume, sampling duration, and cardiac contractility on pulse pressure and stroke volume variation during positive-pressure ventilation. Crit Care Med. 2008;36(10):2858–62.PubMedCentral CrossRef PubMed
    6.Suehiro K, Okutani R. Influence of tidal volume for stroke volume variation to predict fluid responsiveness in patients undergoing one-lung ventilation. Jpn Soc Anesthesiol. 2011;25(5):777–80.
    7.Biais M, Nouette-Gaulain K, Cottenceau V, Revel P, Sztark F. Uncalibrated pulse contour-derived stroke volume variation predicts fluid responsiveness in mechanically ventilated patients undergoing liver transplantation. Br J Anaesth. 2008;101:761–8.CrossRef PubMed
    8.Jacques D, Bendjelid K, Duperret S, Colling J, Piriou V, Viale JP. Pulse pressure variation and stroke volume variation during increased intra-abdominal pressure: an experimental study. Crit Care. 2011;15:R33.PubMedCentral CrossRef PubMed
    9.Chin JH, Lee EH, Hwang GS, Choi WJ. Prediction of fluid responsiveness using dynamic preload indices in patients undergoing robot-assisted surgery with pneumoperitoneum in the Trendelenburg position. Anaesth Intensive Care. 2013;41(5):515–22.PubMed
    10.Darlong V, Kunhabdulla NP, Pandey R, Chandralekha Puni J, Garq R, Kumar R. Hemodynamic changes during robotic radical prostatectomy. Saudi J Anaesth. 2012;6(3):213–8.PubMedCentral CrossRef PubMed
    11.Hadian M, Severyn DA, Pinsky MR. The effects of vasoactive drugs on pulse pressure and stroke volume variation in postoperative ventilated patients. J Crit Care. 2011;26(3):328.e1–8.CrossRef
    12.Wajima Z, Shiga T, Imanaga K, Inoue T. Do induced hypertension and hypotension affect stroke volume variation in man. J Clin Anesth. 2012;24(3):207–11.CrossRef PubMed
    13.Pinsky MR. Instantaneous venous return curves in an intact canine preparation. J Appl Physiol. 1984;56:765–71.PubMed
    14.Michard F, Chemla D, Richard C, et al. Clinical use of respiratory changes in arterial pulse pressure to monitor the hemodynamic effects of PEEP. Am J Respir Crit Care Med. 1999;159:935–9.CrossRef PubMed
    15.Reuter DA, Bayerlein J, Goepfert MSG, et al. Influence of tidal volume on left ventricular stroke volume variation measured by pulse contour analysis in mechanically ventilated patients. Intensive Care Med. 2003;29:476–80.PubMed
    16.Thiele RH, Nemergut EC, Lynch C 3rd. The physiologic implications of isolated alpha(1) adrenergic stimulation. Anesth Analg. 2011;113:284–96.CrossRef PubMed
    17.Thiele RH, Nemergut EC, Lynch C 3rd. The clinical implications of isolated alpha(1) adrenergic stimulation. Anesth Analg. 2011;113:297–304.CrossRef PubMed
    18.Butterworth J. Do alpha agonist increase venous return? Anesthesiology 2004; 101:1038. Author reply 1039.
    19.Simon AC, Levenson JA, Levy BY, Bouthier JE, Peronneau PP, Safar ME. Effect of nitroglycerin on peripheral large arteries in hypertension. Br J Clin Pharmacol. 1982;14:241–6.PubMedCentral CrossRef PubMed
    20.Toraman F, Karabulut H, Goksel O, Evrenkaya S, Tarcan S, Alhan C. Comparison of antihypertensives after coronary artery surgery. Asian Cardiovasc Thorac Ann. 2005;13:302–6.CrossRef PubMed
    21.Pinsky MR. The dynamic interface between hemodynamic variables and autonomic tone. Crit Care Med. 2005;33:2437–8.CrossRef PubMed
  • 作者单位:Ran Kong (1)
    Yi Liu (1)
    Weidong Mi (1)
    Qiang Fu (1)

    1. Department of Anesthesiology, People’s Liberation Army General Hospital, 28 Fuxing Road, Haidian District, Beijing, 100853, China
  • 刊物类别:Medicine
  • 刊物主题:Medicine & Public Health
    Anesthesiology
    Intensive and Critical Care Medicine
    Statistics for Life Sciences, Medicine and Health Sciences
  • 出版者:Springer Netherlands
  • ISSN:1573-2614
文摘
Pulse pressure variation (PPV) and stroke volume variation (SVV) during mechanical ventilation have been shown to be effective parameters to predict preload responsiveness. Although induced hypertension decreases PPV and SVV, the influences of different vasopressors on PPV and SVV are unknown. 94 patients undergoing elective otologic surgery were randomly divided into three groups: Group P (patients were given phenylephrine), Group D (patients were given dopamine), Group E (patients were given ephedrine). When surgery was ongoing and the circulation state was stable, patients were given the vasopressor to increase the systolic arterial pressure (SAP) to the pre-calculated levels: low level, 10 % < ΔSAP ≤ 20 %; medium level, 20 % < ΔSAP ≤ 30 %; high level, 30 % < ΔSAP ≤ 40 %. When invasive arterial pressure reached the target value, PPV, SVV and other parameters were recorded. Dopamine decreased the PPV and SVV more significantly than ephedrine, but less significantly than phenylephrine. The influences of phenylephrine, dopamine and ephedrine on SVV and PPV are different due to their different pharmacological mechanisms. Keywords Phenylephrine Dopamine Ephedrine Pulse pressure variation Stroke volume variation

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700