Feasibility analysis of a hybrid off-grid wind–DG-battery energy system for the eco-tourism remote areas
详细信息    查看全文
  • 作者:SK. A. Shezan ; R. Saidur ; K. R. Ullah…
  • 关键词:Renewable energy ; Wind energy ; Wind turbines HOMER ; Diesel generator ; Sensitivity analysis ; Optimization ; Hybrid model
  • 刊名:Clean Technologies and Environmental Policy
  • 出版年:2015
  • 出版时间:December 2015
  • 年:2015
  • 卷:17
  • 期:8
  • 页码:2417-2430
  • 全文大小:2,109 KB
  • 参考文献:Abdullah M, Yung V, Anyi M, Othman A, Ab Hamid K, Tarawe J (2010) Review and comparison study of hybrid diesel/solar/hydro/fuel cell energy schemes for a rural ICT Telecenter. Energy 35(2):639-46CrossRef
    Abutayeh M, Goswami YD, Stefanakos EK (2013) Solar thermal power plant simulation. Environ Prog Sustain Energy 32(2):417-24CrossRef
    Ajan CW, Ahmed SS, Ahmad HB, Taha F, Mohd Zin AAB (2003) On the policy of photovoltaic and diesel generation mix for an off-grid site: east Malaysian perspectives. Sol Energy 74(6):453-67CrossRef
    Ali R, Daut I, Taib S (2012) A review on existing and future energy sources for electrical power generation in Malaysia. Renew Sustain Energy Rev 16(6):4047-055CrossRef
    Alwi SRW, Tin OS, Rozali NEM, Manan ZA, Kleme? JJ (2013) New graphical tools for process changes via load shifting for hybrid power systems based on power pinch analysis. Clean Technol Environ Policy 15(3):459-72CrossRef
    Bechrakis D, McKeogh E, Gallagher P (2006) Simulation and operational assessment for a small autonomous wind–hydrogen energy system. Energy Convers Manag 47(1):46-9CrossRef
    Bouzerdoum M, Mellit A, Massi Pavan A (2013) A hybrid model (SARIMA–SVM) for short-term power forecasting of a small-scale grid-connected photovoltaic plant. Solar Energy 98:226-35 Part C(0) CrossRef
    Bravo Y, Monné C, Bernal N, Carvalho M, Moreno F, Mu?oz M (2014) Hybridization of solar dish-stirling technology: analysis and design. Environ Prog Sustain Energy 33:1459-466
    Chinchilla M, Arnaltes S, Burgos JC (2006) Control of permanent-magnet generators applied to variable-speed wind-energy systems connected to the grid. IEEE Trans Energy Convers 21(1):130-35CrossRef
    Cucchiella F, D’Adamo I, Gastaldi M (2013) Financial analysis for investment and policy decisions in the renewable energy sector. Clean Technol Environ Policy 1-8
    Dalton G, Lockington D, Baldock T (2009) Case study feasibility analysis of renewable energy supply options for small to medium-sized tourist accommodations. Renew Energy 34(4):1134-144CrossRef
    Fokaides PA, Miltiadous I-C, Neophytou MK-A, Spyridou L-P (2014) Promotion of wind energy in isolated energy systems: the case of the Orites wind farm. Clean Technol Environ Policy 16(3):477-88CrossRef
    Ho WS, Hashim H, Lim JS, Kleme? JJ (2013) Combined design and load shifting for distributed energy system. Clean Technol Environ Policy 15(3):433-44CrossRef
    Ho WS, Khor CS, Hashim H, Macchietto S, Kleme? JJ (2014) SAHPPA: a novel power pinch analysis approach for the design of off-grid hybrid energy systems. Clean Technol Environ Policy 16(5):957-70CrossRef
    Hossain FM, Hasanuzzaman M, Rahim N, Ping H (2014) Impact of renewable energy on rural electrification in Malaysia: a review. Clean Technol Environ Policy 1-3
    Hossain AK, Badr O (2007) Prospects of renewable energy utilisation for electricity generation in Bangladesh. Renew Sustain Energy Rev 11(8):1617-649CrossRef
    Jaafar A, Akli CR, Sareni B, Roboam X, Jeunesse A (2009) Sizing and energy management of a hybrid locomotive based on flywheel and accumulators. IEEE Trans Veh Technol 58(8):3947-958CrossRef
    Jacobus H, Lin B, Jimmy DH, Ansumana R, Malanoski AP, Stenger D (2011) Evaluating the impact of adding energy storage on the performance of a hybrid power system. Energy Convers Manag 52(7):2604-610CrossRef
    Jain A, Chalapathi Rao P, Choudhury P, Mehta R, Mittal SK (2013a) Optimization studies for hybrid and storage designs for parabolic solar trough systems with the system advisor model. Environ Prog Sustain Energy 32(4):1247-254CrossRef
    Jain A, Vu T, Mehta R, Mittal SK (2013b) Optimizing the cost and performance of parabolic trough solar plants with thermal energy storage in India. Environ Prog Sustain Energy 32(3):824-29CrossRef
    Kirschen DS, Strbac G (2004) Fundamentals of power system economics. Wiley, HobokenCrossRef
    Lau KY, Yousof M, Arshad S, Anwari M, Yatim A (2010) Performance analysis of hybrid photovoltaic/diesel energy system under Malaysian conditions. Energy 35(8):3245-255CrossRef
    Lee S, Pradhan B (2007) Landslide hazard mapping at Selangor, Malaysia using frequency ratio and logistic regression models. Landslides 4(1):33-1CrossRef
    Molera L, Pilar Albaladejo I (2007) Profiling segments of tourists in rural areas of South-Eastern Spain. Tour Manag 28(3):757-67CrossRef
    Nandi SK, Ghosh HR (2009) A wind–PV-battery hybrid power system at Sitakunda in Bangladesh. Energy Policy 37(9):3659-664CrossRef
    Ngan MS, Tan CW (2012) Assessment of economic viability for PV/wind/diesel hybrid energy system in southern Peninsular Malaysia. Renew Sustain Energy Rev 16(1):634-47CrossRef
    Pradhan B, Sezer EA, Gokceoglu C, Buchroithner MF (2010) Landslide susceptibility mapping by neuro-fuzzy approach in a landslide-prone area (Cameron Highlands, Malaysia). IEEE Trans Geosci Remote Sens 48(12):4164-177CrossRef
    Shafiullah G, Oo AM, Ali AS, Wolfs P (2013) Po
  • 作者单位:SK. A. Shezan (1)
    R. Saidur (3)
    K. R. Ullah (2)
    A. Hossain (1)
    W. T. Chong (1)
    S. Julai (1)

    1. Department of Mechanical Engineering, Faculty of Engineering, University of Malaya, 50603, Kuala Lumpur, Malaysia
    3. Center of Research Excellence in Renewable Energy (CoRE-RE), King Fahd University of Petroleum and Minerals (KFUPM), Dhahran, 31261, Saudi Arabia
    2. UM Power Energy Dedicated Advanced Centre (UMPEDAC), Level 4, Wisma R&D UM, University of Malaya, 59990, Kuala Lumpur, Malaysia
  • 刊物类别:Engineering
  • 刊物主题:Industrial and Production Engineering
    Industrial Chemistry and Chemical Engineering
    Industrial Pollution Prevention
    Environmental Economics
  • 出版者:Springer Berlin / Heidelberg
  • ISSN:1618-9558
文摘
The electrification process of the remote areas and decentralized areas is being a vital fact for the improvement of its eco-tourism issues such as the Cameron Highland of Malaysia. Renewable energy (RE) resources can be used extensively to support and fulfill the demand of the expected loads of these areas. This article presents an analysis of a complete off-grid wind–diesel-battery hybrid RE model. The main objective of the present analysis is to visualize the optimum volume of systems capable of fulfilling the requirements of 85 kWh/day primary load in coupled with 8.7 kW peak for 2 residential hotels of Cameron Highlands. The hybrid power system can be effective for the tourists of that area as it is a decentralized region of Malaysia. The main motto of this analysis is to minimize the electricity unit cost and ensure the most reliable and feasible system to fulfill the requirements of the desired or expected energy system using HOMER software. From the simulation result, it can be seen that 15 wind turbines (10 kW), 1 diesel generator (4 kW), and 2 battery (Hoppecke 4 OPzS) hybrid RE system is the most economically feasible and lowest cost of energy is nearing USD 0.199/kWh and net present cost is USD 77, 019. The decrement of the CO2 emissions also can be identified from the simulation results using that most feasible RE system including the renewable fraction value which is about 0.0914, 0.3 % capacity shortage and 20.3 % electricity as storage as compared to the other energy system. Keywords Renewable energy Wind energy Wind turbines HOMER Diesel generator Sensitivity analysis Optimization Hybrid model

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700