Energy vessel sealing systems versus mechanical ligature of the inferior mesenteric artery in laparoscopic sigmoidectomy
详细信息    查看全文
  • 作者:Bertrand Trilling ; Romain Riboud ; Julio Abba…
  • 关键词:Inferior mesenteric artery ; Energized vessel sealing systems ; Mechanical ligature ; Colectomy ; Laparoscopy ; Diverticulitis
  • 刊名:International Journal of Colorectal Disease
  • 出版年:2016
  • 出版时间:April 2016
  • 年:2016
  • 卷:31
  • 期:4
  • 页码:903-908
  • 全文大小:281 KB
  • 参考文献:1.Faynsod M, Stamos MJ, Arnell T et al (2000) A case-control study of laparoscopic versus open sigmoid colectomy for diverticulitis. Am Surg 66:841–843PubMed
    2.Dwivedi A, Chahin F, Agrawal S et al (2002) Laparoscopic colectomy vs. open colectomy for sigmoid diverticular disease. Dis Colon Rectum 45:1309–1314. doi:10.​1097/​01.​DCR.​0000029596.​61627.​6A , discussion 1314–1315CrossRef PubMed
    3.Alves A, Panis Y, Slim K et al (2005) French multicentre prospective observational study of laparoscopicversus open colectomy for sigmoid diverticular disease. Br J Surg 92:1520–1525. doi:10.​1002/​bjs.​5148 CrossRef PubMed
    4.Levack M, Berger D, Sylla P et al (2011) Laparoscopy decreases anastomotic leak rate in sigmoid colectomy for diverticulitis. Arch Surg Chic Ill 1960 146:207–210. doi:10.​1001/​archsurg.​2010.​325
    5.Targarona EM, Balague C, Marin J et al (2005) Energy sources for laparoscopic colectomy: a prospective randomized comparison of conventional electrosurgery, bipolar computer-controlled electrosurgery and ultrasonic dissection. Operative outcome and costs analysis. Surg Innov 12:339–344CrossRef PubMed
    6.Heniford BT, Matthews BD, Sing RF et al (2001) Initial results with an electrothermal bipolar vessel sealer. Surg Endosc 15:799–801. doi:10.​1007/​s004640080025 CrossRef PubMed
    7.Tou S, Malik AI, Wexner SD, Nelson RL (2011) Energy source instruments for laparoscopic colectomy. Cochrane Database Syst Rev. doi:10.​1002/​14651858.​CD007886.​pub2 PubMed
    8.Sankaranarayanan G, Resapu RR, Jones DB et al (2013) Common uses and cited complications of energy in surgery. Surg Endosc 27:3056–3072. doi:10.​1007/​s00464-013-2823-9 CrossRef PubMed PubMedCentral
    9.Dindo D, Demartines N, Clavien P-A (2004) Classification of surgical complications: a new proposal with evaluation in a cohort of 6336 patients and results of a survey. Ann Surg 240:205–213. doi:10.​1097/​01.​sla.​0000133083.​54934.​ae CrossRef PubMed PubMedCentral
    10.Cirocchi R, Trastulli S, Farinella E et al (2012) High tie versus low tie of the inferior mesenteric artery in colorectal cancer: a RCT is needed. Surg Oncol 21:e111–e123. doi:10.​1016/​j.​suronc.​2012.​04.​004 CrossRef PubMed
    11.Cirocchi R, Trastulli S, Farinella E et al (2012) Is inferior mesenteric artery ligation during sigmoid colectomy for diverticular disease associated with increased anastomotic leakage? A meta-analysis of randomized and non-randomized clinical trials: IMA ligation in sigmoidectomy for diverticular disease. Colorectal Dis 14:e521–e529. doi:10.​1111/​j.​1463-1318.​2012.​03103.​x CrossRef PubMed
    12.Harold KL, Pollinger H, Matthews BD et al (2003) Comparison of ultrasonic energy, bipolar thermal energy, and vascular clips for the hemostasis of small-, medium-, and large-sized arteries. Surg Endosc 17:1228–1230. doi:10.​1007/​s00464-002-8833-7 CrossRef PubMed
    13.Leonardo C, Guaglianone S, De Carli P et al (2005) Laparoscopic nephrectomy using Ligasure system: preliminary experience. J Endourol Endourol Soc 19:976–978. doi:10.​1089/​end.​2005.​19.​976 CrossRef
    14.Ikeda M, Hasegawa K, Sano K et al (2009) The vessel sealing system (LigaSure) in hepatic resection: a randomized controlled trial. Ann Surg 250:199–203. doi:10.​1097/​SLA.​0b013e3181a334f9​ CrossRef PubMed
    15.Cakabay B, Sevinç MM, Gömceli I et al (2009) Ligasure versus clamp-and-tie in thyroidectomy: a single-center experience. Adv Ther 26:1035–1041. doi:10.​1007/​s12325-009-0078-6 CrossRef PubMed
    16.Bansal N, Roberts WS, Apte SM et al (2009) Electrothermal bipolar coagulation decreases the rate of red blood cell transfusions for pelvic exenterations. J Surg Oncol 100:511–514. doi:10.​1002/​jso.​21372 CrossRef PubMed
    17.Campagnacci R, de Sanctis A, Baldarelli M et al (2007) Electrothermal bipolar vessel sealing device vs. ultrasonic coagulating shears in laparoscopic colectomies: a comparative study. Surg Endosc 21:1526–1531. doi:10.​1007/​s00464-006-9143-2 CrossRef PubMed
    18.Adamina M, Champagne BJ, Hoffman L et al (2011) Randomized clinical trial comparing the cost and effectiveness of bipolar vessel sealers versus clips and vascular staplers for laparoscopic colorectal resection. Br J Surg 98:1703–1712. doi:10.​1002/​bjs.​7679 CrossRef PubMed
    19.Takada M, Ichihara T, Kuroda Y (2005) Comparative study of electrothermal bipolar vessel sealer and ultrasonic coagulating shears in laparoscopic colectomy. Surg Endosc 19:226–228. doi:10.​1007/​s00464-004-9072-x CrossRef PubMed
    20.Hübner M, Demartines N, Muller S et al (2008) Prospective randomized study of monopolar scissors, bipolar vessel sealer and ultrasonic shears in laparoscopic colorectal surgery. Br J Surg 95:1098–1104. doi:10.​1002/​bjs.​6321 CrossRef PubMed
    21.Marcello PW, Roberts PL, Rusin LC et al (2006) Vascular pedicle ligation techniques during laparoscopic colectomy: a prospective randomized trial. Surg Endosc 20:263–269. doi:10.​1007/​s00464-005-0258-7 CrossRef PubMed
    22.Morino M, Rimonda R, Allaix ME et al (2005) Ultrasonic versus standard electric dissection in laparoscopic colorectal surgery: a prospective randomized clinical trial. Ann Surg 242:897–901. doi:10.​1097/​01.​sla.​0000189607.​38763.​c5 CrossRef PubMed PubMedCentral
    23.Rimonda R, Arezzo A, Garrone C et al (2009) Electrothermal bipolar vessel sealing system vs. harmonic scalpel in colorectal laparoscopic surgery: a prospective, randomized study. Dis Colon Rectum 52:657–661. doi:10.​1007/​DCR.​0b013e3181a0a70a​ CrossRef PubMed
    24.Alfonsi P, Slim K, Chauvin M et al (2014) French guidelines for enhanced recovery after elective colorectal surgery. J Visc Surg 151:65–79. doi:10.​1016/​j.​jviscsurg.​2013.​10.​006 CrossRef PubMed
    25.Martin ST, Heeney A, Pierce C et al (2011) Use of an electrothermal bipolar sealing device in ligation of major mesenteric vessels during laparoscopic colorectal resection. Tech Coloproctol 15:285–289. doi:10.​1007/​s10151-011-0707-3 CrossRef PubMed
    26.Person B, Vivas DA, Ruiz D et al (2008) Comparison of four energy-based vascular sealing and cutting instruments: a porcine model. Surg Endosc 22:534–538. doi:10.​1007/​s00464-007-9619-8 CrossRef PubMed
    27.Goldstein SL, Harold KL, Lentzner A et al (2002) Comparison of thermal spread after ureteral ligation with the Laparo-Sonic ultrasonic shears and the Ligasure system. J Laparoendosc Adv Surg Tech A 12:61–63. doi:10.​1089/​1092642027534869​57 CrossRef PubMed
    28.Scarborough JE, Mantyh CR, Sun Z, Migaly J (2015) Combined mechanical and oral antibiotic bowel preparation reduces incisional surgical site infection and anastomotic leak rates after elective colorectal resection: an analysis of colectomy-targeted ACS NSQIP. Ann Surg 262:331–337. doi:10.​1097/​SLA.​0000000000001041​ CrossRef PubMed
    29.Fournel I, Tiv M, Soulias M et al (2010) Meta-analysis of intraoperative povidone-iodine application to prevent surgical-site infection. Br J Surg 97:1603–1613. doi:10.​1002/​bjs.​7212 CrossRef PubMed
    30.Cheng KP, Roslani AC, Sehha N et al (2012) ALEXIS O-Ring wound retractor vs conventional wound protection for the prevention of surgical site infections in colorectal resections. Colorectal Dis 14:e346–e351. doi:10.​1111/​j.​1463-1318.​2012.​02943.​x CrossRef PubMed
  • 作者单位:Bertrand Trilling (1) (2)
    Romain Riboud (1) (3)
    Julio Abba (1)
    Edouard Girard (1) (2)
    Jean-Luc Faucheron (1) (2)

    1. Colorectal Unit, Department of Surgery, Michalon University Hospital, CS 10 217, 38 043, Grenoble cedex, France
    2. Grenoble Alpes University, UMR 5525, CNRS, TIMC-IMAG, Grenoble, France
    3. Visceral Surgery Department, Voiron Regional Hospital, Voiron, France
  • 刊物类别:Medicine
  • 刊物主题:Medicine & Public Health
    Surgery
    Internal Medicine
    Gastroenterology
    Hepatology
    Proctology
  • 出版者:Springer Berlin / Heidelberg
  • ISSN:1432-1262
文摘
Purpose With the development of new devices, our ligation technique of the inferior mesenteric artery changed from mechanical ligature (ML) to energized vessel sealing systems (EVSS) ligature. The aim of this study was to determine if EVSS could be considered as safe and effective as the more convention ML of the inferior mesenteric vessels division during elective laparoscopic left colectomy.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700