A 3He beam stop for minimizing gamma-ray and fast-neutron background
详细信息    查看全文
文摘
Prompt gamma-ray activation analysis facilities with high neutron currents (≥109 s−1) generate triton-induced fast neutrons from 6Li-loaded collimators and beam stops at rates that damage gamma-ray detectors. We develop an alternative beam stop design using 3He gas that produces negligible gamma-ray and fast-neutron background following neutron absorption. Replacing a 6Li glass beam stop with a test cell containing 2.5 MPa cm of 3He reduced fast neutron production by 73 %. An optimal 3He beam stop design with a 100-µm-thick entrance window, modeled using MCNP6, enables operation of detectors closer to the beam stop.