Biomechanical stability of a supra-acetabular pedicle screw Internal Fixation device (INFIX) vs External Fixation and plates for vertically unstable pelvic fractures
详细信息    查看全文
  • 作者:Jonathan M Vigdorchik (1)
    Amanda O Esquivel (2)
    Xin Jin (3)
    King H Yang (3)
    Ndidi A Onwudiwe (1)
    Rahul Vaidya (1)
  • 刊名:Journal of Orthopaedic Surgery and Research
  • 出版年:2012
  • 出版时间:December 2012
  • 年:2012
  • 卷:7
  • 期:1
  • 全文大小:1524KB
  • 参考文献:1. Gardner MJ, Kendoff D, Ostermeier S, Citak M, Hüfner T, Krettek C, Nork SE: Sacroiliac joint compression using an anterior pelvic compressor: a mechanical study in synthetic bone. / J Orthop Trauma 2007,21(7):435-41. CrossRef
    2. Gardner MJ, Nork SE: Stabilization of unstable pelvic fractures with supraacetabular compression external fixation. / J Orthop Trauma 2007,21(4):269273. CrossRef
    3. Grimm MR, Vrahas MS, Thomas KA: Pressure-volume characteristics of the intact and disrupted pelvic retroperitoneum. / J Trauma 1998,44(3):454-59. CrossRef
    4. Kregor PJ, Routt ML Jr: Unstable pelvic ring disruptions in unstable patients. / Injury 1999,30(Suppl 2):B19-B28. CrossRef
    5. Riemer BL, Butterfield SL, Diamond DL, Young JC, Raves JJ, Cottington E, Kislan K: Acute mortality associated with injuries to the pelvic ring: the role of early patient mobilization and external fixation. / J Trauma 1993,35(5):671-75. discussion 676-77 CrossRef
    6. Hupel TM, McKee MD, Waddell JP, Schemitsch EH: Primary external fixation of rotationally unstable pelvic fractures in obese patients. / J Trauma 1998,45(1):111-15. CrossRef
    7. Vaidya R, Colen R, Vigdorchik J, Tonnos F, Sethi A: Treatment of unstable pelvic ring injuries with an internal anterior fixator and posterior fixation: initial clinical series. / J Orthop Trauma 2012,26(1):1-. CrossRef
    8. Vaidya R, Kubiak EN, Bergin PF, Dombroski DG, Critchlow RJ, Sethi A, Starr AJ: Complications of Anterior Subcutaneous Internal Fixation for Unstable Pelvis Fractures: a Multicenter Study. / Clin Orthop Relat Res 2012. Epub ahead of print
    9. Varga E, Hearn T, Powell J, Tile M: Effects of method of internal fixation of symphyseal disruptions on stability of the pelvic ring. / Injury 1995, 26:75-0. CrossRef
    10. Yinger K, Scalise J, Olson SA, Bay BK, Finkemeier CG: Biomechanical comparison of posterior pelvic ring fixation. / J Orthop Trauma 2003,17(7):481-87. CrossRef
    11. Ponsen KJ, Joosse P, Van Dijke GA, Snijders CJ: External fixation of the pelvic ring: an experimental study on the role of pin diameter, pin position, and parasymphyseal fixator pins. / Acta Orthop 2007,78(5):648-53. CrossRef
    12. Pohlemann T, Angst M, Schneider E, Ganz R, Tscherne H: Fixation of transforaminal sacrum fractures: a biomechanical study. / J Orthop Trauma 1993,7(2):107-17. CrossRef
    13. Shaw JA, Mino DE, Werner FW, Murray DG: Posterior stabilization of pelvic fractures by use of threaded compression rods. Case reports and mechanical testing. / Clin Orthop Relat Res 1985, 192:240-54.
    14. Comstock CP, van der Meulen MC, Goodman SB: Biomechanical comparison of posterior internal fixation techniques for unstable pelvic fractures. / J Orthop Trauma 1996, 10:517-22. CrossRef
    15. Leighton RK, Waddell JP, Bray TJ, Bray TJ, Hapman MW, Simpson L, Martin RB, Sharkey NA: Biomechanical testing of new and old fixation devices for vertical shear fractures of the pelvis. / J Orthop Trauma 1991, 5:313-17. CrossRef
    16. Simonian PT, Routt C Jr, Harrington RM, Tencer AF: Internal fixation for the transforaminal sacral fracture. / Clin Orthop Relat Res 1996, 323:202-09. CrossRef
    17. Simonian PT, Routt ML Jr, Harrington RM, Mayo KA, Tencer AF: Biomechanical simulation of the anteroposterior compression injury of the pelvis. An understanding of instability and fixation. / Clin Orthop Relat Res 1994, 309:245-56.
    18. Simonian PT, Routt ML Jr, Harrington RM, Tencer AF: Internal fixation of the unstable anterior pelvic ring: a biomechanical comparison of standard plating techniques and the retrograde medullary superior pubic ramus screw. / J Orthop Trauma 1994,8(6):476-82.
    19. Van Zwienen CM, van den Bosch EW, Snijders CJ, Kleinrensink GJ, van Vugt AB: Biomechanical comparison of sacroiliac screw techniques for unstable pelvic ring fractures. / J Orthop Trauma 2004, 18:589-95. CrossRef
    20. Dujardin FH, Roussignol X, Hossenbaccus M, Thomine JM: Experimental study of the sacroiliac joint micromotion in pelvic disruption. / J Orthop Trauma 2002, 16:99-03. CrossRef
    21. MacAvoy MC, McClellan RT, Goodman SB, Chien CR, Allen WA, van der Meulen MC: Stability of open-book pelvic fractures using a new biomechanical model of single-limb stance. / J Orthop Trauma 1997, 11:590-93. CrossRef
    22. Pohlemann T, Culemann U, Tscherne H: Comparative biomechanical studies of internal stabilization of trans-foraminal sacrum fractures. / Orthopade 1992,21(6):413-21.
    23. Rubash HE, Brown TD, Nelson DD, Mears DC: Comparative mechanical performances of some new devices for fixation of unstable pelvic ring fractures. / Med Biol Eng Comput 1983, 21:657-63. CrossRef
  • 作者单位:Jonathan M Vigdorchik (1)
    Amanda O Esquivel (2)
    Xin Jin (3)
    King H Yang (3)
    Ndidi A Onwudiwe (1)
    Rahul Vaidya (1)

    1. Detroit Receiving Hospital, 4201 St Antoine St, Detroit, MI, 48201, USA
    2. Providence Hospital and Medical Centers, 16001 West 9 Mile Road, Southfield, MI, USA
    3. Wayne State University, 540 E Canfield St, Detroit, MI, USA
文摘
Background We have recently developed a subcutaneous anterior pelvic fixation technique (INFIX). This internal fixator permits patients to sit, roll over in bed and lie on their sides without the cumbersome external appliances or their complications. The purpose of this study was to evaluate the biomechanical stability of this novel supraacetabular pedicle screw internal fixation construct (INFIX) and compare it to standard internal fixation and external fixation techniques in a single stance pelvic fracture model. Methods Nine synthetic pelves with a simulated anterior posterior compression type III injury were placed into three groups (External Fixator, INFIX and Internal Fixation). Displacement, total axial stiffness, and the stiffness at the pubic symphysis and SI joint were calculated. Displacement and stiffness were compared by ANOVA with a Bonferroni adjustment for multiple comparisons Results The mean displacement at the pubic symphysis was 20, 9 and 0.8?mm for external fixation, INFIX and internal fixation, respectively. Plate fixation was significantly stiffer than the INFIX and external Fixator (P--.01) at the symphysis pubis. The INFIX device was significantly stiffer than external fixation (P--.017) at the symphysis pubis. There was no significant difference in SI joint displacement between any of the groups. Conclusions Anterior plate fixation is stiffer than both the INFIX and external fixation in single stance pelvic fracture model. The INFIX was stiffer than external fixation for both overall axial stiffness, and stiffness at the pubic symphysis. Combined with the presumed benefit of minimizing the complications associated with external fixation, the INFIX may be a more preferable option for temporary anterior pelvic fixation in situations where external fixation may have otherwise been used.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700