Non-contact imaging of venous compliance in humans using an RGB camera
详细信息    查看全文
  • 作者:Kazuya Nakano ; Ryota Satoh ; Akira Hoshi ; Ryohei Matsuda ; Hiroyuki Suzuki
  • 关键词:Venous compliance ; Skin hemodynamics ; RGB image ; Monte Carlo simulation ; Upper ; arm occlusion ; Non ; contact measurement
  • 刊名:Optical Review
  • 出版年:2015
  • 出版时间:April 2015
  • 年:2015
  • 卷:22
  • 期:2
  • 页码:335-341
  • 全文大小:1,127 KB
  • 参考文献:1.T. Wada, K. Kodaira, K. Fujishiro, K. Maie, E. Tsukiyama, T. Fukumoto, T. Uchida, S. Yamazaki, Correlation of ultrasound-measured common carotid artery stiffness with pathological finding.聽Arterioscler Thromb. 14, 479 (1994)View Article
    2.J.C. Bramwell, A.V. Hill, Velocity transmission of the pulse wave and elasticity of arteries. Lancet 199, 891 (1922)View Article
    3.A. Yamashina, H. Tomiyama, K. Takeda, H. Tsuda, T. Arai, K. Hirose, Y. Koji, S. Hori, Y. Yamamoto, Validity, reproducibility, and clinical significance of noninvasive brachial-ankle pulse wave velocity measurement.聽Hypertens. Res. 25, 359 (2002)View Article
    4.S. Laurent, P. Boutouyrie, R. Asmar, I. Gautier, B. Laloux, L. Guize, P. Ducimetiere, A. Benetos, Aortic stiffness is an independent predictor of all-cause and cardiovascular mortality in hypertensive patients.聽Hypertension 37, 1236 (2001)View Article
    5.K.D. Monahan, F.A. Dikenno, D.R. Seals, J.R. Halliwill, Smaller age-associated reductions in leg venous compliance in endurance exercise-trained men. Am. J. Physiol. Heart Circ. Physiol. 281, 1267 (2001)
    6.J.P. Hernandez, W.D. Franke, Age- and fitness-related differences in limbs venous compliance do not affect tolerance to maximal lower body negative pressure in men and women. J. Appl. Physiol. 97(2004), 925 (1985)
    7.J.P. Hernandez, W.D. Franke, Effect of a 6-mo endurance training program on venous compliance and maximal lower body negative pressure in older men and women. J. Appl. Physiol. 99(2005), 1070 (1985)
    8.H. Kawano, M. Tanimoto, K. Yamamoto, Y. Gando, K. Sanada, I. Tabata, M. Higuchi, M. Miyachi, Greater forearm venous compliance in resistance-trained men.聽Eur. J. Appl. Physiol. 110, 769 (2010)View Article
    9.A.P. Avolio, S.G. Chen, R.P. Wang, C.L. Zhang, M.F. Li, M.F. O鈥橰ourke, Effects of aging on changing arterial compliance and left ventricular load in a northern Chinese urban community.聽Circulation 68, 50 (1983)View Article
    10.C.N. Young, M.E. Stillabower, A. DiSabatino, W.B. Farquhar, Venous smooth muscle tone and responsiveness in older adults.聽J. Appl. Physiol. 101(2006), 1362 (1985)
    11.W. W. Nichols, M. F. O鈥橰ourke, in McDonald鈥檚 Blood Flow in Arteries: Theoretical. Experimental and Clinical Principles, 3rd edn. (Edward Arnold, London, 1990), p. 77
    12.K.D. Monahan, C.A. Ray, Gender affects calf venous compliance at rest and during baroreceptor unloading in humans. Am. J. Physiol. Heart Circ. Physiol. 286, 895 (2004)View Article
    13.D.E. Hokanson, D.S. Sumner, D.E. Strandness, An electrically calibrated plethysmograph for direct measurement of limb blood flow. IEEE Trans. Biomed. Eng. 22, 25 (1975)View Article
    14.T. Thomsen, D. Hokanson, R. Barnes, Automatic quantitation of venous hemodynamics with an electrically calibrated strain gauge plethysmograph. 聽Med. Instrum. 11, 240 (1977)
    15.J.R. Halliwill, C.T. Minton, M.J. Joyner, Measurement of limb venous compliance in humans: technical considerations and physiological findings. J. Appl. Physiol. 87(1999), 1555 (1985)
    16.J.C. Buckey, L.D. Lane, G. Plath, F.A. Gaffney, F. Baisch, C.G. Blomqvist, Effects of head-down tilt for 10 days on the compliance of the leg. Acta Physiol. Scand. 144, 53 (1992)
    17.F.M. Melchior, S.M. Fortney, Orthostatic intolerance during a 13-day bed rest does not result from increased leg compliance. J. Appl. Physiol. 74(1993), 286 (1985)
    18.I. Nishidate, K. Sasaoka, T. Yuasa, K. Niizeki, T. Maeda, Y. Aizu, Visualizing of skin chromophore concentrations by use of RGB images. Opt. Lett. 33, 2263 (2008)View Article ADS
    19.I. Nishidate, N. Tanaka, T. Kawase, T. Maeda, T. Yuasa, Y. Aizu, T. Yuasa, K. Niizeki, Noninvasive imaging of human skin hemodynamics using a digital red-green-blue camera.聽J. Biomed. Opt. 16, 086012 (2011)View Article ADS
    20.I. Nishidate, N. Tanaka, T. Kawase, T. Maeda, T. Yuasa, Y. Aizu, T. Yuasa, K. Niizeki, Visualization of peripheral vasodilative indices in human skin by use of red, green, blue images. J. Biomed. Opt. 18, 061220 (2013)View Article ADS
  • 作者单位:Kazuya Nakano (1)
    Ryota Satoh (2)
    Akira Hoshi (2)
    Ryohei Matsuda (2)
    Hiroyuki Suzuki (3)
    Izumi Nishidate (2)

    1. Nippon Sport Science University, 1221-1 Kamoshidacho, Aobaku, Yokohama, Kanagawa, 227-0033, Japan
    2. Graduate School of Bio-Application and Systems Engineering, Tokyo University of Agriculture and Technology, Koganei, Tokyo, 184-8588, Japan
    3. Imaging Science and Engineering Laboratory, Tokyo Institute of Technology, Nagatsuta-cho, Midori-ku, Yokohama, Kanagawa, 226-8503, Japan
  • 刊物类别:Physics and Astronomy
  • 刊物主题:Physics
    Electromagnetism, Optics and Lasers
  • 出版者:The Optical Society of Japan, co-published with Springer-Verlag GmbH
  • ISSN:1349-9432
文摘
We propose a technique for non-contact imaging of venous compliance that uses the red, green, and blue (RGB) camera. Any change in blood concentration is estimated from an RGB image of the skin, and a regression formula is calculated from that change. Venous compliance is obtained from a differential form of the regression formula. In vivo experiments with human subjects confirmed that the proposed method does differentiate the venous compliances among individuals. In addition, the image of venous compliance is obtained by performing the above procedures for each pixel. Thus, we can measure venous compliance without physical contact with sensors and, from the resulting images, observe the spatial distribution of venous compliance, which correlates with the distribution of veins.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700