Clinical applications of SPECT/CT in imaging the extremities
详细信息    查看全文
  • 作者:Martin W. Huellner (1)
    Klaus Strobel (2)

    1. Department of Medical Radiology
    ; Division of Nuclear Medicine ; University Hospital Zurich ; 8091 ; Zurich ; Switzerland
    2. Department of Nuclear Medicine and Radiology
    ; Lucerne Cantonal Hospital ; 6004 ; Lucerne ; Switzerland
  • 关键词:SPECT/CT ; Musculoskeletal imaging ; Prostheses ; Arthroplasty ; Knee ; Hip ; Shoulder ; Elbow ; Hand/wrist ; Foot ; Bone
  • 刊名:European Journal of Nuclear Medicine and Molecular Imaging
  • 出版年:2014
  • 出版时间:May 2014
  • 年:2014
  • 卷:41
  • 期:1-supp
  • 页码:50-58
  • 全文大小:860 KB
  • 参考文献:1. Hegenscheid, K, Puls, R, Rosenberg, C (2012) Imaging strategies for knee injuries. Radiologe 52: pp. 980-986 3" target="_blank" title="It opens in new window">CrossRef
    2. Kaur, J, Chopra, R (2010) Three dimensional CT reconstruction for the evaluation and surgical planning of mid face fractures: a 100 case study. J Maxillofac Oral Surg 9: pp. 323-328 3-010-0137-1" target="_blank" title="It opens in new window">CrossRef
    3. Chen, KN, Wang, G, Cao, LG, Zhang, MC (2009) Differences of percutaneous retrograde screw fixation of anterior column acetabular fractures between male and female: a study of 164 virtual three-dimensional models. Injury 40: pp. 1067-1072 CrossRef
    4. Brown, GA, Firoozbakhsh, K, Gehlert, RJ (2001) Three-dimensional CT modeling versus traditional radiology techniques in treatment of acetabular fractures. Iowa Orthop J 21: pp. 20-24
    5. Heiba, SI, Kolker, D, Mocherla, B, Kapoor, K, Jiang, M, Son, H (2010) The optimized evaluation of diabetic foot infection by dual isotope SPECT/CT imaging protocol. J Foot Ankle Surg 49: pp. 529-536 3/j.jfas.2010.07.010" target="_blank" title="It opens in new window">CrossRef
    6. Yang, DC, Ratani, RS, Mittal, PK, Chua, RS, Pate, SM (2002) Radionuclide three-phase whole-body bone imaging. Clin Nucl Med 27: pp. 419-426 3072-200206000-00007" target="_blank" title="It opens in new window">CrossRef
    7. Pankaj, A, Kotwal, PP, Mittal, R, Deepak, KK, Bal, CS (2006) Diagnosis of post-traumatic complex regional pain syndrome of the hand: current role of sympathetic skin response and three-phase bone scintigraphy. J Orthop Surg (Hong Kong) 14: pp. 284-290
    8. Huellner, MW, Burkert, A, Schleich, FS, Schurch, M, Hug, U, Wartburg, U (2012) SPECT/CT versus MRI in patients with nonspecific pain of the hand and wrist 鈥?a pilot study. Eur J Nucl Med Mol Imaging 39: pp. 750-759 34-3" target="_blank" title="It opens in new window">CrossRef
    9. Linke, R, Kuwert, T, Uder, M, Forst, R, Wuest, W (2010) Skeletal SPECT/CT of the peripheral extremities. AJR Am J Roentgenol 194: pp. W329-W335 3288" target="_blank" title="It opens in new window">CrossRef
    10. Ito S, Yamamoto Y, Tanii T, Aga F, Nishiyama Y. SPECT/CT imaging in ulnocarpal impaction syndrome. Clin Nucl Med. 2013. doi:10.1097/RLU.0b013e31828da39d
    11. Allainmat, L, Aubault, M, Noel, V, Baulieu, F, Laulan, J, Eder, V (2013) Use of hybrid SPECT/CT for diagnosis of radiographic occult fractures of the wrist. Clin Nucl Med 38: pp. e246-e251 3e318263819e" target="_blank" title="It opens in new window">CrossRef
    12. Schleich, FS, Schurch, M, Huellner, MW, Hug, U, Wartburg, U, Strobel, K (2012) Diagnostic and therapeutic impact of SPECT/CT in patients with unspecific pain of the hand and wrist. EJNMMI Res 2: pp. 53 3" target="_blank" title="It opens in new window">CrossRef
    13. Tetsumura, A, Honda, E, Sasaki, T, Kino, K (1999) Metallic residues as a source of artifacts in magnetic resonance imaging of the temporomandibular joint. Dentomaxillofac Radiol 28: pp. 186-190 38/sj.dmfr.4600429" target="_blank" title="It opens in new window">CrossRef
    14. Bagheri, MH, Ahmadloo, N, Rezaian, S (2013) Artifacts in magnetic resonance imaging after surgical resection of brain tumors. Magn Reson Imaging 31: pp. 700-702 CrossRef
    15. Henderson, RA, Lachiewicz, PF (2012) Groin pain after replacement of the hip: aetiology, evaluation and treatment. J Bone Joint Surg Br 94: pp. 145-151 302/0301-620X.94B2.27736" target="_blank" title="It opens in new window">CrossRef
    16. Classen, T, Zaps, D, Landgraeber, S, Li, X, Jager, M (2013) Assessment and management of chronic pain in patients with stable total hip arthroplasty. Int Orthop 37: pp. 1-7 CrossRef
    17. Chang, EY, McAnally, JL, Horne, JR, Statum, S, Wolfson, T, Gamst, A (2012) Metal-on-metal total hip arthroplasty: do symptoms correlate with MR imaging findings?. Radiology 265: pp. 848-857 CrossRef
    18. Kruger, T, Hug, U, Hullner, MW, Schleich, F, Veit-Haibach, P, Wartburg, U (2011) SPECT/CT arthrography of the wrist in ulnocarpal impaction syndrome. Eur J Nucl Med Mol Imaging 38: pp. 792 CrossRef
    19. Hirschmann, MT, Schmid, R, Dhawan, R, Skarvan, J, Rasch, H, Friederich, NF (2011) Combined single photon emission computerized tomography and conventional computerized tomography: clinical value for the shoulder surgeons?. Int J Should Surg 5: pp. 72-76 3/0973-6042.86242" target="_blank" title="It opens in new window">CrossRef
    20. Degreef, I, Verduyckt, J, Debeer, P, Smet, L (2005) An unusual cause of shoulder pain: osteoid osteoma of the acromion 鈥?a case report. J Shoulder Elbow Surg 14: pp. 643-644 CrossRef
    21. Berquist, TH (2006) Imaging of joint replacement procedures. Radiol Clin North Am 44: pp. 419-437 CrossRef
    22. Temmerman, OP, Raijmakers, PG, Berkhof, J, Hoekstra, OS, Teule, GJ, Heyligers, IC (2005) Accuracy of diagnostic imaging techniques in the diagnosis of aseptic loosening of the femoral component of a hip prosthesis: a meta-analysis. J Bone Joint Surg Br 87: pp. 781-785 302/0301-620X.87B6.15625" target="_blank" title="It opens in new window">CrossRef
    23. Temmerman, OP, Raijmakers, PG, David, EF, Pijpers, R, Molenaar, MA, Hoekstra, OS (2004) A comparison of radiographic and scintigraphic techniques to assess aseptic loosening of the acetabular component in a total hip replacement. J Bone Joint Surg Am 86-A: pp. 2456-2463
    24. Aliabadi, P, Tumeh, SS, Weissman, BN, McNeil, BJ (1989) Cemented total hip prosthesis: radiographic and scintigraphic evaluation. Radiology 173: pp. 203-206
    25. Callaghan, JJ, Nostrand, D, Dysart, SH, Savory, CG, Hopkins, WJ (1996) Prospective serial technetium diphosphonate and indium-111 white blood cell labeled imaging in primary uncemented total hip arthroplasty. Iowa Orthop J 16: pp. 104-112
    26. Venesmaa, P, Vanninen, E, Miettinen, H, Kroger, H (2012) Periprosthetic bone turnover after primary total hip arthroplasty measured by single-photon emission computed tomography. Scand J Surg 101: pp. 241-248 CrossRef
    27. Strobel, K, Steurer-Dober, I, Huellner, MW, Veit-Haibach, P, Allgayer, B (2012) Importance of SPECT/CT for knee and hip joint prostheses. Radiologe 52: pp. 629-635 3" target="_blank" title="It opens in new window">CrossRef
    28. Love, C, Marwin, SE, Palestro, CJ (2009) Nuclear medicine and the infected joint replacement. Semin Nucl Med 39: pp. 66-78 3/j.semnuclmed.2008.08.007" target="_blank" title="It opens in new window">CrossRef
    29. Graute, V, Feist, M, Lehner, S, Haug, A, Muller, PE, Bartenstein, P (2010) Detection of low-grade prosthetic joint infections using 99mTc-antigranulocyte SPECT/CT: initial clinical results. Eur J Nucl Med Mol Imaging 37: pp. 1751-1759 31-3" target="_blank" title="It opens in new window">CrossRef
    30. Filippi, L, Schillaci, O (2006) Usefulness of hybrid SPECT/CT in 99mTc-HMPAO-labeled leukocyte scintigraphy for bone and joint infections. J Nucl Med 47: pp. 1908-1913
    31. Luk, WH, Au-Yeung, AW, Yang, MK (2010) Diagnostic value of SPECT versus SPECT/CT in femoral avascular necrosis: preliminary results. Nucl Med Commun 31: pp. 958-961 3e32833e7732" target="_blank" title="It opens in new window">CrossRef
    32. Sutter, R, Ulbrich, EJ, Jellus, V, Nittka, M, Pfirrmann, CW (2012) Reduction of metal artifacts in patients with total hip arthroplasty with slice-encoding metal artifact correction and view-angle tilting MR imaging. Radiology 265: pp. 204-214 CrossRef
    33. Bryant, LR, Song, WS, Banks, KP, Bui-Mansfield, LT, Bradley, YC (2008) Comparison of planar scintigraphy alone and with SPECT for the initial evaluation of femoral neck stress fracture. AJR Am J Roentgenol 191: pp. 1010-1015 3592" target="_blank" title="It opens in new window">CrossRef
    34. Buck, FM, Hoffmann, A, Hofer, B, Pfirrmann, CW, Allgayer, B (2009) Chronic medial knee pain without history of prior trauma: correlation of pain at rest and during exercise using bone scintigraphy and MR imaging. Skeletal Radiol 38: pp. 339-347 CrossRef
    35. Strobel, K, Wiesmann, R, Tornquist, K, Steurer-Dober, I, Muller, U (2012) SPECT/CT arthrography of the knee. Eur J Nucl Med Mol Imaging 39: pp. 1975-1976 3-4" target="_blank" title="It opens in new window">CrossRef
    36. Sacchetti, GM, Ghisellini, F, Brambilla, M, Consoli, A, Fornara, P, Rizzo, E (1996) Quantitative scintigraphic evaluation of total knee arthroplasties: a feasibility study. Clin Orthop Relat Res 325: pp. 181-189 3086-199604000-00021" target="_blank" title="It opens in new window">CrossRef
    37. Smith, SL, Wastie, ML, Forster, I (2001) Radionuclide bone scintigraphy in the detection of significant complications after total knee joint replacement. Clin Radiol 56: pp. 221-224 3/crad.2000.0620" target="_blank" title="It opens in new window">CrossRef
    38. Hirschmann, MT, Iranpour, F, Konala, P, Kerner, A, Rasch, H, Cobb, JP (2010) A novel standardized algorithm for evaluating patients with painful total knee arthroplasty using combined single photon emission tomography and conventional computerized tomography. Knee Surg Sports Traumatol Arthrosc 18: pp. 939-944 CrossRef
    39. Hirschmann, MT, Konala, P, Iranpour, F, Kerner, A, Rasch, H, Friederich, NF (2011) Clinical value of SPECT/CT for evaluation of patients with painful knees after total knee arthroplasty 鈥?a new dimension of diagnostics?. BMC Musculoskelet Disord 12: pp. 36 36" target="_blank" title="It opens in new window">CrossRef
    40. Hirschmann, MT, Mathis, D, Afifi, FK, Rasch, H, Henckel, J, Amsler, F (2013) Single photon emission computerized tomography and conventional computerized tomography (SPECT/CT) for evaluation of patients after anterior cruciate ligament reconstruction: a novel standardized algorithm combining mechanical and metabolic information. Knee Surg Sports Traumatol Arthrosc 21: pp. 965-974 3-6" target="_blank" title="It opens in new window">CrossRef
    41. Hirschmann, MT, Mathis, D, Rasch, H, Amsler, F, Friederich, NF, Arnold, MP (2013) SPECT/CT tracer uptake is influenced by tunnel orientation and position of the femoral and tibial ACL graft insertion site. Int Orthop 37: pp. 301-309 CrossRef
    42. Rasch, H, Falkowski, AL, Forrer, F, Henckel, J, Hirschmann, MT (2013) 4D-SPECT/CT in orthopaedics: a new method of combined quantitative volumetric 3D analysis of SPECT/CT tracer uptake and component position measurements in patients after total knee arthroplasty. Skeletal Radiol 42: pp. 1215-1223 3-1643-2" target="_blank" title="It opens in new window">CrossRef
    43. Testa, EA, Rasch, H, Forrer, F, Hirschmann, MT (2013) Clinical value of 4D-SPECT/CT in patients with painful total knee arthroplasty. Br J Sports Med 47: pp. e3
    44. Hirschmann, MT, Henckel, J, Rasch, H (2013) SPECT/CT in patients with painful knee arthroplasty 鈥?what is the evidence?. Skeletal Radiol 42: pp. 1201-1207 3-1657-9" target="_blank" title="It opens in new window">CrossRef
    45. Biersack, HJ, Wingenfeld, C, Hinterthaner, B, Frank, D, Sabet, A (2012) SPECT-CT of the foot. Nuklearmedizin 51: pp. 26-31 3413/Nukmed-0421-11-08" target="_blank" title="It opens in new window">CrossRef
    46. Pagenstert, GI, Barg, A, Leumann, AG, Rasch, H, Muller-Brand, J, Hintermann, B (2009) SPECT-CT imaging in degenerative joint disease of the foot and ankle. J Bone Joint Surg Br 91: pp. 1191-1196 302/0301-620X.91B9.22570" target="_blank" title="It opens in new window">CrossRef
    47. Singh, VK, Javed, S, Parthipun, A, Sott, AH (2013) The diagnostic value of single photon-emission computed tomography bone scans combined with CT (SPECT-CT) in diseases of the foot and ankle. Foot Ankle Surg 19: pp. 80-83 CrossRef
    48. Chicklore, S, Gnanasegaran, G, Vijayanathan, S, Fogelman, I (2013) Potential role of multislice SPECT/CT in impingement syndrome and soft-tissue pathology of the ankle and foot. Nucl Med Commun 34: pp. 130-139 3e32835c0964" target="_blank" title="It opens in new window">CrossRef
    49. Davies, M, Cassar-Pullicino, VN, Davies, AM, McCall, IW, Tyrrell, PN (2002) The diagnostic accuracy of MR imaging in osteoid osteoma. Skeletal Radiol 31: pp. 559-569 CrossRef
    50. Newman, JS, Newberg, AH (2000) Congenital tarsal coalition: multimodality evaluation with emphasis on CT and MR imaging. Radiographics 20: pp. 321-332 3321" target="_blank" title="It opens in new window">CrossRef
    51. Filippi, L, Uccioli, L, Giurato, L, Schillaci, O (2009) Diabetic foot infection: usefulness of SPECT/CT for 99mTc-HMPAO-labeled leukocyte imaging. J Nucl Med 50: pp. 1042-1046 3" target="_blank" title="It opens in new window">CrossRef
  • 刊物类别:Medicine
  • 刊物主题:Medicine & Public Health
    Nuclear Medicine
    Imaging and Radiology
    Orthopedics
    Cardiology
    Oncology
  • 出版者:Springer Berlin / Heidelberg
  • ISSN:1619-7089
文摘
Today, SPECT/CT is increasingly used and available in the majority of larger nuclear medicine departments. Several applications of SPECT/CT as a supplement to or replacement for traditional conventional bone scintigraphy have been established in recent years. SPECT/CT of the upper and lower extremities is valuable in many conditions with abnormal bone turnover due to trauma, inflammation, infection, degeneration or tumour. SPECT/CT is often used in patients if conventional radiographs are insufficient, if MR image quality is impaired due to metal implants or in patients with contraindications to MR. In complex joints such as those in the foot and wrist, SPECT/CT provides exact anatomical correlation of pathological uptake. In many cases SPECT increases the sensitivity and CT the specificity of the study, increasing confidence in the final diagnosis compared to planar images alone. The CT protocol should be adapted to the clinical question and may vary from very low-dose (e.g. attenuation correction only), to low-dose for anatomical correlation, to normal-dose protocols enabling precise anatomical resolution. The aim of this review is to give an overview of SPECT/CT imaging of the extremities with a focus on the hand and wrist, knee and foot, and for evaluation of patients after joint arthroplasty.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700