Estimation of Radius of Curvature of Lumbar Spine Using Bending Sensor for Low Back Pain Prevention
详细信息    查看全文
  • 关键词:Bending sensor ; Herniated disk ; Wearable sensing system ; Radius of curvature
  • 刊名:Lecture Notes in Computer Science
  • 出版年:2015
  • 出版时间:2015
  • 年:2015
  • 卷:9299
  • 期:1
  • 页码:533-536
  • 全文大小:536 KB
  • 参考文献:1.Andersson, B.J.G., Örtengren, R., Nachemson, A., Elfström, G.: Lumbar disc pressure and myoelectric back muscle activity during sitting, I. Studies on an experimental chair. Scand. J. Rehabil. Med. 6, 104–114 (1974)
    2.Rohlman, A., Zander, T., Schmidt, H., Wilke, H.-J., Bergmann, G.: Analysis of the influence of disc degeneration on the mechanical behavior of a lumbar motion segment using the finite element method. J. Biomech. 39, 2484–2490 (2006)CrossRef
    3.Shibata, K., Inoue, Y., Iwata, Y., Katagawa, J., Fujii, R.: Study on noninvasive estimate method for intervertebral disk load at lumbar vertebrae. Jpn. Soc. Mech. Eng. 78(791), 2483–2495 (2012)CrossRef
  • 作者单位:Takakuni Iituka (19)
    Kyoko Shibata (19)
    Yoshio Inoue (19)

    19. Kochi University of Technology, Miyanokuchi 185, Tosayamada, Kami, Kochi, Japan
  • 丛书名:Human-Computer Interaction ᾿INTERACT 2015
  • ISBN:978-3-319-22723-8
  • 刊物类别:Computer Science
  • 刊物主题:Artificial Intelligence and Robotics
    Computer Communication Networks
    Software Engineering
    Data Encryption
    Database Management
    Computation by Abstract Devices
    Algorithm Analysis and Problem Complexity
  • 出版者:Springer Berlin / Heidelberg
  • ISSN:1611-3349
文摘
Estimation of the disk load in order to prevent low back pain is useful. However, the conventional methods of measuring disc load are invasive and their use is limited due to measurement environments. This study proposes a new method of estimating the lumbar disc load to measure curvature of the lumbar portion and to estimate the lumbar disc load safely using a bending sensor. The radius curvature can be measured relatively easily and without damaging the body by using this method. The bending sensors are attached along vertebra end of five vertebras and the curvature of the lumbar portion is estimated by reading the change in output voltage. The lumbar disk load with static posture was estimated by proposed method. The result shows the same tendency as the previous method. The proposed method has a possibility of developing a new system using the biofeedback based on the lumbar disc load.