Evaluation of the BreastSimulator Software Platform for Breast Tomography: Preliminary Results
详细信息    查看全文
  • 关键词:Breast computed tomography ; Noise power spectrum ; Breast software phantoms ; X ; ray simulations
  • 刊名:Lecture Notes in Computer Science
  • 出版年:2016
  • 出版时间:2016
  • 年:2016
  • 卷:9699
  • 期:1
  • 页码:145-151
  • 全文大小:1,345 KB
  • 参考文献:1.Longo, R., et al.: Towards breast tomography with synchrotron radiation at Elettra: first images. Phys. Med. Biol. 61, 1634–1649 (2016)CrossRef
    2.McKinley, R.L., et al.: Initial study of quasi-monochromatic X-ray beam performance for X-ray computed mammotomography. IEEE Trans. Nucl. Sci. 52, 1243–1250 (2005)CrossRef
    3.Mettivier, G., et al.: Dedicated scanner for laboratory investigations on cone-beam CT/SPECT imaging of the breast. Nucl. Meth. A 629, 350–356 (2011)CrossRef
    4.Sarno, A., Mettivier, G., Russo, P.: Dedicated breast computed tomography: basic aspects. Med. Phys. 42, 2786–2804 (2015)CrossRef
    5.Mettivier, G., et al.: Glandular dose in breast computed tomography. Phys. Med. Biol. 61, 569–587 (2016)CrossRef
    6.Lanconelli, N., et al.: Investigation of the dose distribution for a cone beam CT system dedicated to breast imaging. Physica Med. 29, 379–387 (2013)CrossRef
    7.Bliznakova, K., et al.: A three-dimensional breast software phantom for mammography simulation. Phys. Med. Biol. 48, 3699–3719 (2003)CrossRef
    8.Bliznakova, K., et al.: Evaluation of an improved algorithm for producing realistic 3D breast software phamtoms: application of mammography. Med. Phys. 37, 5604–5617 (2010)CrossRef
    9.Lindfors, K.K., et al.: Dedicated breast CT: initial clinical experience. Radiology 246, 725–733 (2008)CrossRef
    10.O’Connell, A., et al.: Cone-beam CT for breast imaging: radiation dose, breast coverage, and image quality. Am. J. Roentgenol. 195, 496–509 (2010)CrossRef
    11.Metheani, K.G., et al.: Characterizing anatomical variability in breast CT images. Med. Phys. 35, 4685–4694 (2008)CrossRef
    12.Chen, L., et al.: Association between power law coefficients of the anatomical noise power spectrum and lesion detectability in breast imaging modalities. Phys. Med. Biol. 58, 1663–1681 (2013)CrossRef
  • 作者单位:Giovanni Mettivier (16)
    Kristina Bliznakova (17)
    Francesca Di Lillo (16)
    Antonio Sarno (16)
    Paolo Russo (16)

    16. Dipartimento di Fisica “Ettore Pancini”, Università di Napoli Federico II, and INFN Sezione di Napoli, Naples, Italy
    17. Department of Electronics, Technical University of Varna, Varna, Bulgaria
  • 丛书名:Breast Imaging
  • ISBN:978-3-319-41546-8
  • 刊物类别:Computer Science
  • 刊物主题:Artificial Intelligence and Robotics
    Computer Communication Networks
    Software Engineering
    Data Encryption
    Database Management
    Computation by Abstract Devices
    Algorithm Analysis and Problem Complexity
  • 出版者:Springer Berlin / Heidelberg
  • ISSN:1611-3349
  • 卷排序:9699
文摘
The aim of this work is the evaluation of the software BreastSimulator, as a tool for the creation of 3D uncompressed breast digital models and for the simulation and the optimization of Computed Tomography (CT) equipment. Three 3D digital breast phantoms were created, having different sizes and with realistic anatomical features. We calculated 2D X-ray CT projections simulating a breast tomogram with a dedicated cone-beam CT scanner. From the reconstructed CT slices, the power-law exponent, has been evaluated from the Noise Power Spectrum function S(f) = α/f β. The results were then verified by comparison against clinical CT and published data. The preliminary results of this study showed that the simulated model complexity may reproduce the real anatomical complexity of the breast tissues as described, in terms of β values, since the measured β coefficients are close to that of clinical CT data from a dedicated breast CT scanner.