Refractive outcomes comparison between the Lenstar LS 900? optical biometry and immersion A-scan ultrasound
详细信息    查看全文
  • 作者:Palanyraj Naicker ; Siva Sundralingam ; Mohammadreza Peyman…
  • 关键词:Refractive outcomes ; Lenstar LS 900? ; Immersion A ; Scan ultrasound ; Phacoemulsification
  • 刊名:International Ophthalmology
  • 出版年:2015
  • 出版时间:August 2015
  • 年:2015
  • 卷:35
  • 期:4
  • 页码:459-466
  • 全文大小:476 KB
  • 参考文献:1.Jasvinder S, Khang TF, Sarinder KKS, Loo VP, Subrayan V (2011) Agreement analysis of Lenstar with other techniques of biometry. Eye 25:717-24PubMed Central PubMed View Article
    2.Nemeth G, Nagy A, Berta A, Modis LJ (2012) Comparison of intraocular lens power prediction using immersion ultrasound and optical biometry with and without formula optimization. Graefes Arch Clin Exp Ophthalmol 250(9):1321-325PubMed View Article
    3.Landers J, Goggin M (2009) Comparison of refractive outcomes using immersion ultrasound biometry and IOL master biometry. Clin Exp 37:566-69
    4.Narvaez J, Cherwek DH, Stulting RD, Waldron R, Zimmerman GJ, Wessels IE, Waring GO III (2008) Comparing Immersion ultrasound with partial coherence interferometry for intraocular lens power calculation. Ophthalmic Surg Lasers Imaging 39:30-4PubMed View Article
    5.Lam S (2013) Comparing optical low coherence reflectometry and immersion ultrasound in refractive outcome after cataract surgery. J Cataract Refract Surg 39(2):297-98PubMed View Article
    6.Fendl O, Kriechbaum K, Sacu S et al (2003) Influence of operator experience on the performance of ultrasound biometry compared to optical biometry before cataract surgery. J Cataract Refract Surg 29:1950-955View Article
    7.Trivedi RH, Wilson ME (2011) Prediction error after pediatric cataract surgery with intraocular lens implantation: contact versus immersion A-scan biometry. J Cataract Refract Surg 37:501-05PubMed View Article
    8.Chang SW, Yu CY, Chen DP (2009) Comparison of intraocular lens power calculation by the IOL master in phakic and eyes with hydrophobic acrylic lenses. Ophthalmology 116:1336-342PubMed View Article
    9.Hennessy MP, Chan DG (2003) Contact versus immersion biometry of axial length before cataract surgery. J Cataract Refract Surg 29:2195-198PubMed View Article
    10.Watson A, Armstrong R (1999) Contact or immersion technique for axial length measurement? Aust N Z J Ophthalmol 27:49-1PubMed View Article
    11.Olsen T, Nielsen PJ (1989) Immersion versus contact technique in the measurement of axial length by ultrasound. Acta Ophthalmol (Copenh) 67:101-02View Article
    12.Shammas HJ (1984) A comparison of immersion and contact techniques for axial length measurement. Am Intra-Ocular Implant Soc J 10:444-47View Article
    13.Tsang CS, Chong GS, Yiu EP, Ho CK (2003) Intraocular lens power calculation formulas in Chinese eyes with high axial myopia. J Cataract Refract Surg 29(7):1358-364PubMed View Article
    14.Gale RP, Saldana M, Johnston RL, Zuberbuhler B, McKibbin M (2009) Benchmark standards for refractive outcomes after NHS cataract surgery. Eye 23:149-52PubMed View Article
    15.Hahn U, Krummenauer F, Kolbl B, Neuhann T, Schayan-Araghi K, Schmickler S, von Wolff K, Weindler J, Will T, Neuhann I (2011) Determination of valid benchmarks for outcome indicators in cataract surgery; a multicenter, prospective cohort trial. Ophthalmology 118:2011-105View Article
    16.Butcher JM, O’Brien C (1991) The reproducibility of biometry and keratometry measurements. Eye 5:708-11PubMed View Article
    17.Raj PS, Ilango B, Watson A (1998) Measurement of axial length in the calculation of intraocular lens power. Eye 12:227-29PubMed View Article
  • 作者单位:Palanyraj Naicker (1)
    Siva Sundralingam (1)
    Mohammadreza Peyman (1)
    Azida Juana (1)
    Nor Fadhilah Mohamad (1)
    Maung Maung Win (1)
    Angela Loo (1)
    Visvaraja Subrayan (1)

    1. Department of Ophthalmology, University of Malaya, 59100, Kuala Lumpur, Malaysia
  • 刊物类别:Medicine
  • 刊物主题:Medicine & Public Health
    Ophthalmology
  • 出版者:Springer Netherlands
  • ISSN:1573-2630
文摘
To determine the accuracy of intraocular lens (IOL) calculations in eyes undergoing phacoemulsification cataract surgery with IOL implantation using immersion A-scan ultrasound (US) and Lenstar LS 900? biometry. In this prospective study, 200 eyes of 200 patients were randomized to undergo either Lenstar LS 900? or immersion A-scan US biometry to determine the IOL dioptric power prior to phacoemulsification cataract surgery. Post-operative refractive outcomes of these two groups of patients were compared. The result showed no significant difference between the target spherical equivalent (SE) and the post-operative SE value by the Lenstar LS 900? (p value?=?0.632) or immersion A-scan US biometry (p value?=?0.438) devices. The magnitude of difference between the two biometric devices were not significantly different (p value?=?0.868). There was no significant difference in the predicted post-operative refractive outcome between immersion A-scan US biometry and Lenstar LS 900?. Based on the results, the immersion A-scan US technique is as accurate as Lenstar LS 900? in the hands of an experienced operator.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700