Biomechanical comparison of two stabilization techniques for unstable sacral fractures
详细信息    查看全文
  • 作者:Tamás Bodzay (1) bodzaytamas@freemail.hu
    János Szita (1)
    Sándor Manó (23)
    László Kiss (3)
    Zoltán Jónás (3)
    Sándor Frenyó (1)
    Zoltán Csernátony (23)
  • 刊名:Journal of Orthopaedic Science
  • 出版年:2012
  • 出版时间:September 2012
  • 年:2012
  • 卷:17
  • 期:5
  • 页码:574-579
  • 全文大小:342.5 KB
  • 参考文献:1. Denis F, Davis S, Comfort T. Sacral fractures: an important problem retrospective analysis of 236 cases. Clin Orthop Relat Res. 1988;227:67–81.
    2. Gibbons K, Soloniuk D, Razack N. Neurological injury and patterns of sacral fractures. J Neurosurg. 1990;72:889–93.
    3. Ragnarsson B, Olerud C, Olerud S. Anterior square-plate fixation of sacroiliac disruption 2–8 years follow up of 23 consecutive cases. Acta Orthop Scand. 1993;64(2):138–42.
    4. Szita J. Experimental and clinical analysis of pelvic ring injuries (doctoral thesis). Budapest: Semmelweis University; 1992.
    5. van Zwienen CMA, van den Bosch EW, Snijders CJ, Kleinrensink G. Biomechanical comparison of sacroiliac screw techniques for unstable pelvic ring fractures. J Orthop Trauma. 2004;18:589–95.
    6. Schildhauer TA, Ledoux WR, Chapman JR, Henley MB, Tencer AF, Routt ML Jr. Triangular osteosynthesis and iliosacral screw fixation for unstable sacral fractures: a cadaveric and biomechanical evaluation under cyclic loads. J Orthop Trauma. 2003;17:2–31.
    7. Sagi HC, Ordway NR, DiPasquale T. Biomechanical analysis of fixation for vertically unstable sacroiliac dislocations with iliosacral screws and symphyseal plating. J Orthop Trauma. 2004;18:138–43.
    8. MacAvoy M, McCellan R, Trigg P, Goodman SB, Chien Chi-Ray D, Allen WA, van der Meulen MCH. Stability of open book pelvic fractures using a new biomechanical model of single-limb stance. J Orthop Trauma. 1997;11:590–3.
    9. van den Bosch E, van Zwienen C, van den Bosch E, Hoek van Dijke GA, Snijders CJ, van Vugt AB. Sacroiliac screw fixation for tile B fractures. J Trauma. 2003;55:962–5.
    10. Bodzay T, Burján T, Bagdi C, Flóris I, Vendégh Zs, Váradi K. Evaluation of stabilization methods of pelvic ring injuries by finite element modeling. Joint Dis Relat Surg. 2007;18(3):108–15.
    11. Li Z, Kim J, Davidson J, Etheridge B, Alonso J, Eberhardt A. Biomechanical response of the pubic symphysis in lateral pelvic impacts: a finite element study. J Biomech. 2007;40(12):2758–66.
    12. Hüfner T, Pohlemann T, Tarte S, G?nslen A, Geerling J, Bazak N, Citak M, Nolte LP, Krettek C. Computer-assisted fracture reduction of pelvic ring fractures: an in vitro study. Clin Orthop Relat Res. 2002;399:231–9.
    13. Yinger K, Scalise J, Olson S, Bay B, Finkemeyer C. Biomechanical comparison of pelvic ring fixation. J Orthop Trauma. 2003;17:481–7.
  • 作者单位:1. Trauma Center Péterfy Hospital, Fiumei ut 17, 1081 Budapest, Hungary2. Laboratory of Biomechanics, University of Debrecen, Debrecen, Hungary3. Department of Orthopaedics, University of Debrecen, Medical and Health Science Center, Nagyerdei ut 98, 4012 Debrecen, Hungary
  • ISSN:1436-2023
文摘
Aim The purpose of the study was to assess the stability provided by an ilio-iliac dorsal plate fixation technique using an AO narrow DCP on the pelvic brim in vertically and rotationally unstable type-C pelvic ring injuries.