Primary side control of load voltage for transcutaneous energy transmission
详细信息    查看全文
  • 作者:Yang Fu ; Liang Hu ; Xiaodong Ruan ; Xin Fu
  • 关键词:Transcutaneous energy transmission ; Primary side control ; Artificial heart
  • 刊名:Journal of Artificial Organs
  • 出版年:2016
  • 出版时间:March 2016
  • 年:2016
  • 卷:19
  • 期:1
  • 页码:14-20
  • 全文大小:2,212 KB
  • 参考文献:1.Holman WL, Kirklin JK, Naftel DC, Kormos RL, Desvign-Nickens P, Camacho MT, et al. Infection after implantation of pulsatile mechanical circulatory support devices. J Thorac Cardiovasc Surg. 2010;139:1632–6 e2.CrossRef PubMed
    2.Houghton P. Living with the Jarvik 2000: a five-plus year experience. Artif Organs. 2006;30:322–3.CrossRef PubMed
    3.Fang W, Liu W, Qian J, Tang H, Ye P. Modeling and simulation of a transcutaneous energy transmission system used in artificial organ implants. Artif Organs. 2009;33:1069–74.CrossRef PubMed
    4.Ozeki T, Chinzei T, Abe Y, Saito I, Isoyama T, Ono T, et al. Preliminary study of a new type of energy transmission system for artificial hearts. J Artif Organs. 2003;6:0014–9.CrossRef
    5.Yamamoto T, Koshiji K, Homma A, Tatsumi E, Taenaka Y. Improvement in magnetic field immunity of externally-coupled transcutaneous energy transmission system for a totally implantable artificial heart. J Artif Organs. 2008;11:238–40.CrossRef PubMed
    6.Slaughter MS, Myers TJ. Transcutaneous energy transmission for mechanical circulatory support systems: history, current status, and future prospects. J Card Surg. 2010;25:484–9.CrossRef PubMed
    7.Chen Q, Wong SC, Tse CK, Ruan X. Analysis, design, and control of a transcutaneous power regulator for artificial hearts. IEEE Trans Biomed Circuits Syst. 2009;3:23–31.CrossRef
    8.Wang B, Hu AP, Budgett D. Power flow control based solely on slow feedback loop for heart pump applications. IEEE Trans Biomed Circuits Syst. 2012;6:279–86.CrossRef PubMed
    9.Si P, Hu AP, Malpas S, Budgett D. A frequency control method for regulating wireless power to implantable devices. IEEE Trans Biomed Circuits Syst. 2008;2:22–9.CrossRef
    10.Tamura N, Yamamoto T, Aoki H, Koshiji K, Homma A, Tatsumi E, et al. Investigation of unifying transcutaneous transformer for transmission of energy and information. J Artif Organs. 2009;12:138–40.CrossRef PubMed
    11.Fu Y, Hu L, Ruan X, Fu X. A transcutaneous energy transmission system for artificial heart adapting to changing impedance. Artif Organs. 2015;39:378–87.CrossRef PubMed
    12.Åström KJ, Hägglund T. Automatic tuning of simple regulators with specifications on phase and amplitude margins. Automatica. 1984;20:645–51.CrossRef
  • 作者单位:Yang Fu (1)
    Liang Hu (1)
    Xiaodong Ruan (1)
    Xin Fu (1)

    1. The State Key Laboratory of Fluid Power Transmission and Control, Zhejiang University, Zheda Road 38, Hangzhou, 310027, China
  • 刊物类别:Medicine
  • 刊物主题:Medicine & Public Health
    Surgery
    Cardiac Surgery
    Biomedical Engineering
    Orthopedics
    Nephrology
    Hepatology
  • 出版者:Springer Japan
  • ISSN:1619-0904
文摘
Transcutaneous energy transmission (TET) is considered as a good way to wirelessly power the implanted devices in human bodies. The load voltage provided from the TET to the implanted device should be kept stable to ensure the device working well, which however, is easily affected by the required power variation for different body movements and coil-couple malposition accompanying skin peristalsis. Commonly, the load voltage applied onto the device should be measured and feedback for power is regulated by implanting sensing and communication units into the body, which causes additional energy cost, increased size and weight of the implanted device. This paper takes the TET for artificial heart as an example to propose a novel primary side control method of the load voltage for TET, which does not require any additional implanted components. In the method, sensing coils are used to measure the malposition between the transmitter coil (TC) and receiver coil, and the magnitude of the TC current outside the human body. The measurement results are used to estimate the load voltage inside the body through calculation, whose value provide a base to develop a PI control system to regulate the input power of TET for the load voltage stability. The proposed method is experimentally validated on an actual TET for artificial heart by varying its load in a wide range under serious coil-couple malposition. With applying the primary side control, the variation of the load voltage is reduced to only 25 % of that without the control.