Effects of interpupillary distance on stereoacuity: the Frisby Davis distance stereotest versus a 3-dimensional distance stereotest
详细信息    查看全文
  • 作者:Youngsub Eom ; Jong-Suk Song ; Soh-Eun Ahn ; Su-Yeon Kang…
  • 关键词:Frisby Davis distance stereotest ; Interpupillary distance ; Stereoacuity ; 3 ; dimensional stereotest
  • 刊名:Japanese Journal of Ophthalmology
  • 出版年:2013
  • 出版时间:September 2013
  • 年:2013
  • 卷:57
  • 期:5
  • 页码:486-492
  • 全文大小:373KB
  • 参考文献:1. Von Noorden GK, Campos EC. Binocular vision and ocular motility: theory and management of strabismus. 6th ed. St Louis: Mosby; 2002. p. 21-.
    2. Parks MM. Binocular vision. In: Tasman W, Jaeger EA, editors. Duane’s clinical ophthalmology, vol. 1. Philadelphia: Lippincott; 2000. http://www.oculist.net/downaton502/prof/ebook/duanes/pages/v1/v1c005.html (Accessed 28 July 2012).
    3. Adams WE, Hrisos S, Richardson S, Davis H, Frisby JP, Clarke MP. Frisby Davis distance stereoacuity values in visually normal children. Br J Ophthalmol. 2005;89:1438-1. CrossRef
    4. Stathacopoulos RA, Rosenbaum AL, Zanoni D, Stager DR, McCall LC, Ziffer AJ, et al. Distance stereoacuity: assessing control in intermittent exotropia. Ophthalmology. 1993;100:495-00.
    5. Yildirim C, Altinsoy HI, Yakut E. Distance stereoacuity norms for the mentor B-VAT II-SG video acuity tester in young children and young adults. J AAPOS. 1998;2:26-2. CrossRef
    6. Holmes JM, Fawcett SL. Testing distance stereoacuity with the Frisby-Davis 2 (FD2) test. Am J Ophthalmol. 2005;139:193-. CrossRef
    7. Breyer A, Jiang X, Rutsche A, Mojon DS. A new 3D monitor-based random-dot stereotest for children. Invest Ophthalmol Vis Sci. 2006;47:4842-. CrossRef
    8. Kriegbaum-Stehberger B, Jiang X, Mojon DS. Performance of a new, 3D-monitor based random-dot stereotest for children under 4?years of age. Graefes Arch Clin Exp Ophthalmol. 2008;246:1-. CrossRef
    9. Kim J, Yang HK, Kim Y, Lee B, Hwang JM. Distance stereotest using a 3-dimensional monitor for adult subjects. Am J Ophthalmol. 2011;151:1081-. CrossRef
    10. Jimenez R, Perez MA, Garcia JA, Gonzalez MD. Statistical normal values of visual parameters that characterize binocular function in children. Ophthalmic Physiol Opt. 2004;24:528-2. CrossRef
    11. MacLachlan C, Howland HC. Normal values and standard deviations for pupil diameter and interpupillary distance in subjects aged 1?month to 19?years. Ophthalmic Physiol Opt. 2002;22:175-2. CrossRef
    12. Leske DA, Birch EE, Holmes JM. Real depth vs randot stereotests. Am J Ophthalmol. 2006;142:699-01. CrossRef
    13. Hong SW, Park SC. Development of distant stereoacuity in visually normal children as measured by the Frisby-Davis distance stereotest. Br J Ophthalmol. 2008;92:1186-. CrossRef
    14. Frisby Davis Distance Stereotest Manual. Sheffield: Stereotest Ltd; 2007. p. 4-.
    15. Spencer S, Firth AY. Stereoacuity is affected by induced phoria but returns toward baseline during vergence adaptation. J AAPOS. 2007;11:465-. CrossRef
    16. Legge GE, Gu YC. Stereopsis and contrast. Vision Res. 1989;29:989-004. CrossRef
    17. Lovasik JV, Szymkiw M. Effects of aniseikonia, anisometropia, accommodation, retinal illuminance, and pupil size on stereopsis. Invest Ophthalmol Vis Sci. 1985;26:741-0.
  • 作者单位:Youngsub Eom (1)
    Jong-Suk Song (1)
    Soh-Eun Ahn (1)
    Su-Yeon Kang (1)
    Young-Woo Suh (1)
    Jaeryung Oh (1)
    Seung-Hyun Kim (1)
    Hyo Myung Kim (1)

    1. Department of Ophthalmology, Guro Hospital, Korea University College of Medicine, 80 Guro-dong, Guro-gu, Seoul, 152-703, South Korea
  • ISSN:1613-2246
文摘
Purpose To evaluate the effect of interpupillary distance (IPD) on stereoacuity using 2 kinds of stereoacuity tests in a normal population. Methods The distance stereoacuities of 33 healthy volunteers with no evidence of ocular diseases were measured with the Frisby Davis distance (FD2) stereotest and a 3-dimensional monitor-based distance stereotest (distance 3-D stereotest). These 2 kinds of stereotests were repeated using horizontal periscopes to increase the IPD 2- and 3-fold in order to investigate the effect of IPD increase on stereoacuity. Results The mean age of the participants was 28.5?years (range 20-1?years). The mean logarithms of the individual minimum angle of stereodiscrimination (logMAS) were 1.04?±?0.23 (range 0.70-.48 logMAS) with the FD2 stereotest and 1.52?±?0.19 (range 1.00-.85 logMAS) with the distance 3-D stereotest. As the IPD increased 2- and 3-fold, the logMAS measured with the FD2 stereotest improved from 1.04 to 0.98 and 0.91 (P?=?0.061 and P?=?0.003), respectively, and those measured with the distance 3-D stereotest worsened from 1.52 to 1.73 and 1.85 (P?<?0.001 and P?<?0.001), respectively. Conclusions Changes in IPD measured with the FD2 stereotest exhibited opposite effects to those measured with the distance 3-D stereotest. This reflects what is known to happen in the real world, i.e., that stereoacuity improves as IPD increases.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700