Parametric imaging using contrast-enhanced ultrasound with Sonazoid for hepatocellular carcinoma
详细信息    查看全文
  • 作者:Manabu Watanabe (1)
    Kazue Shiozawa (1)
    Masayoshi Takahashi (1)
    Noritaka Wakui (1)
    Yuichiro Otsuka (2)
    Hironori Kaneko (2)
    Kayoko Tanikawa (3)
    Kazutoshi Shibuya (3)
    Naohisa Kamiyama (4)
    Yasukiyo Sumino (1)
  • 关键词:Contrast ; enhanced ultrasound ; Sonazoid ; Parametric image ; Time ; intensity curve ; Hepatocellular carcinoma
  • 刊名:Journal of Medical Ultrasonics
  • 出版年:2010
  • 出版时间:April 2010
  • 年:2010
  • 卷:37
  • 期:2
  • 页码:81-86
  • 全文大小:432KB
  • 参考文献:1. Hatanaka K, Kudo M, Minami Y, et al. Differential diagnosis of hepatic tumors: value of contrast-enhanced harmonic sonography using the newly developed contrast agent, Sonazoid. Intervirology. 2008;51:61-. CrossRef
    2. Nakano H, Ishida Y, Hatakeyama T, et al. Contrast-enhanced intraoperative ultrasonography equipped with late Kupffer-phase image obtained by sonazoid in patients with colorectal liver metastases. World J Gastroenterol. 2008;14:3207-1. CrossRef
    3. Luo W, Numata K, Morimoto M, et al. Three-dimensional contrast-enhanced sonography of vascular patterns of focal liver tumors: pilot study of visualization methods. AJR Am J Roentgenol. 2009;192:165-3. CrossRef
    4. Shiozawa K, Watanabe M, Sumino Y. Evaluation of the hemodynamic status of focal hepatic lesions 20?mm or less in diameter by contrast-enhanced ultrasonography using Sonazoid. Intervirology. 2009;52:213-2. CrossRef
    5. Sugimoto K, Moriyasu F, Kamiyama N, et al. Correlation between parametric imaging using contrast ultrasound and the histological differentiation of hepatocellular carcinoma. Hepatol Res. 2007;38:273-0. CrossRef
    6. Kudo M. Multistep human hepatocarcinogenesis: correlation of imaging with pathology. J Gastroenterol. 2009;44:112-. CrossRef
    7. Hayashi M, Matsui O, Ueda K, et al. Correlation between the blood supply and grade of malignancy of hepatocellular nodules associated with liver cirrhosis: evaluation by CT during intraarterial injection of contrast medium. AJR Am J Roentgenol. 1999;172:969-6.
    8. Ueda K, Terada T, Nakamura Y, et al. Vascular supply in adenomatous hyperplasia of the liver and hepatocellular: a morphometric study. Hum Pathol. 1992;23:619-6. CrossRef
    9. Huang-Wei C, Bleuzen A, Olar M, et al. Role of parametric imaging in contrast-enhanced sonography of hepatic focal nodular hyperplasia. Interscience. 2006;34:367-3.
    10. Huang-Wei C, Bleuzen A, Bourlier P, et al. Differential diagnosis of focal nodular hyperplasia with quantitative parametric analysis in contrast-enhanced sonography. Invest Radiol. 2006;41:363-. CrossRef
    11. Ogawa S, Kumada T, Toyoda H, et al. Evaluation of pathological features of hepatocellular carcinoma by contrast-enhanced ultrasonography: comparison with pathology on resected specimen. Euro J Radiol. 2006;59:74-1. CrossRef
  • 作者单位:Manabu Watanabe (1)
    Kazue Shiozawa (1)
    Masayoshi Takahashi (1)
    Noritaka Wakui (1)
    Yuichiro Otsuka (2)
    Hironori Kaneko (2)
    Kayoko Tanikawa (3)
    Kazutoshi Shibuya (3)
    Naohisa Kamiyama (4)
    Yasukiyo Sumino (1)

    1. Department of Gastroenterology and Hepatology, Toho University Medical Center, Omori Hospital, 6-11-1, Omorinishi, Ota-ku, Tokyo, 143-8541, Japan
    2. Department of Hepato-Biliary-Pancreatic Surgery, Toho University Medical Center, Omori Hospital, 6-11-1, Omorinishi, Ota-ku, Tokyo, 143-8541, Japan
    3. Department of Surgical Pathology, Toho University Medical Center, Omori Hospital, 6-11-1, Omorinishi, Ota-ku, Tokyo, 143-8541, Japan
    4. The Ultrasound Systems Development Department, Toshiba Medical Systems Corporation, Otawara, Tochigi, Japan
文摘
Purpose To clarify the usefulness of parametric imaging using contrast-enhanced ultrasound (CE-US) with Sonazoid by comparing parametric images of hepatocellular carcinoma (HCC) with histopathological findings. Methods Two patients with HCCs underwent CE-US with Sonazoid before surgical resection. A single focus point was set at the lower margin of the tumor, and a bolus intravenous injection of Sonazoid (0.5?ml) was administered. Images of the ideal scanning plane were displayed in real-time mode for the early vascular phase. We analyzed these images using prototype PC software. The software watches, pixel by pixel, the increase in the intensity due to the inflow of the microbubbles, and displays colors if the intensity becomes larger than a certain threshold. Parametric images were compared with histopathological findings. Results The level of blood flow in the tumor could be visually evaluated using a single image by expressing the detailed hemodynamics of the tumor in terms of differences in color using a time axis appropriate for each case. Conclusions Parametric imaging is a very useful way of facilitating straightforward visualization of the level of blood flow within HCC and the distribution of histopathological findings in single static images.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700