Introduction to a calibration facility for hard X-ray detectors
详细信息    查看全文
  • 作者:Xu Zhou (1) (2)
    XinQiao Li (1)
    YaNing Xie (1)
    CongZhan Liu (1)
    Shu Zhang (1)
    JinJie Wu (2)
    Jian Zhang (2)
    XuFang Li (1)
    YiFei Zhang (1)
    Bing Li (1)
    HongLiang Hu (1)
    YuPeng Chen (1)
    Wei Jiang (2) (3)
    ZeShu Li (2) (4)
  • 关键词:Hard X ; ray ; Calibration ; Monochromator ; Double crystal ; HXMT ; HE ; 95.55.Ka ; 41.50.+h ; 07.85.Fv
  • 刊名:Experimental Astronomy
  • 出版年:2014
  • 出版时间:December 2014
  • 年:2014
  • 卷:38
  • 期:3
  • 页码:433-441
  • 全文大小:549 KB
  • 参考文献:1. Lu, F.J.: The Hard X-ray Modulation Telescope (HXMT): mission and its current status. AAPPS Bull. 19(2) (2009)
    2. Freyberg, M.J., et al.: The MPE X-ray test facility PANTER: calibration of hard X-ray (15-0?keV) optics. Exp. Astron. 20, 405-12 (2005) CrossRef
    3. Burwitz, V., et al.: In focus measurements of IXO type optics using the new PANTER x-ray test facility extension. SPIE Proc. 8861, 88611J (2013) CrossRef
    4. Loffredo, G., et al.: The Ferrara hard X-ray facility for testing/calibrating hard X-ray focusing telescopes. Exp. Astron. 20, 413-20 (2005) CrossRef
    5. Loffredo, G., et al.: The X-ray facility of the physics department of the Ferrara University. Exp. Astron. 18, 1-1 (2004) CrossRef
    6. Kegley, J., et al.: Improved cryogenic test capability at Marshall Space Flight Center’s X-ray Cryogenic Facility. SPIE Proc. 6265, 62654E (2006) CrossRef
    7. Brejnholt, N.F., et al.: NuSTAR ground calibration: the Rainwater Memorial Calibration Facility (RaMCaF). SPIE Proc. 8147-16 (2011)
    8. Brejnholt, N.F., et al.: The Rainwater Memorial Calibration Facility (RaMCaF) for X-ray optics. X-Ray Opt. Instrum. 2011, 285079 (2011) CrossRef
    9. Collura, A., et al.: The X-ray astronomy calibration and testing facility (XACT) at Osservatorio Astronomico Di Palermo G.S. Vaiana. SPIE Proc. 2280, 206-13 (1994) CrossRef
    10. Yan, Y.L, et al.: Applying to the T device and method of the synchrotron radiation stationary exit’s the double crystal monochromator. PRC Patent, ZL 200410083805.3, 2007-09-19
    11. John, M.C.: Diffraction Physics (North-Holland, Amsterdam). ISBN 0-444-10791-6 (1975)
  • 作者单位:Xu Zhou (1) (2)
    XinQiao Li (1)
    YaNing Xie (1)
    CongZhan Liu (1)
    Shu Zhang (1)
    JinJie Wu (2)
    Jian Zhang (2)
    XuFang Li (1)
    YiFei Zhang (1)
    Bing Li (1)
    HongLiang Hu (1)
    YuPeng Chen (1)
    Wei Jiang (2) (3)
    ZeShu Li (2) (4)

    1. Key Laboratory of Particle Astrophysics, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, 100049, China
    2. Division of Ionizing Radiation Metrology, National Institute of Metrology, Beijing, 100013, China
    3. Chengdu University of Technology, Chengdu, 620059, China
    4. Nanhua University, Hengyang, 421001, China
  • ISSN:1572-9508
文摘
This paper introduces the current configuration of the Hard X-ray Calibration Facility (HXCF) in 2014, which is used to calibrate the high energy X-ray detectors that will be onboard the Hard X-ray Modulation Telescope (HXMT) satellite, China’s first astronomy satellite. The HXCF consists of an X-ray tube, a skid platform system, a double crystal monochromator, a “T-structure mechanism, a collimator, an adjustable beam, a background shielding box, as well as the box of the control system. The HXCF covers 15-00?keV energy band and has a high fraction of monochromatic light (exceeding 92?% at 15-00?keV) and good monochromaticity (1-level). The flux of the monochromatic light is around 104 photons cm? s?. This HXCF could be used to calibrate the energy linearities, the energy resolutions and detection efficiencies of hard X-ray detectors.