A clivus plate fixation for reconstruction of ventral defect of the craniovertebral junction: a novel fixation device for craniovertebral instability
详细信息    查看全文
  • 作者:Wei Ji ; Jie Tong ; Zhiping Huang ; Minghui Zheng ; Xiuhua Wu…
  • 关键词:Craniovertebral junction ; Clivus plate ; Biomechanics ; Neutral zone ; Range of motion
  • 刊名:European Spine Journal
  • 出版年:2015
  • 出版时间:August 2015
  • 年:2015
  • 卷:24
  • 期:8
  • 页码:1658-1665
  • 全文大小:1,118 KB
  • 参考文献:1.Lee SC, Chen JF, Lee ST (2004) Complications of fixation to the occiput-anatomical and design implications. Br J Neurosurg 18:590-97PubMed View Article
    2.Suchomel P, Buchvald P, Barsa P et al (2007) Single-stage total C-2 intralesional spondylectomy for chordoma with three-column reconstruction. Technical note. J Neurosurg Spine 6:611-18PubMed View Article
    3.Goel A, Karapurkar AP (1994) Transoral plate and screw fixation of the craniovertebral region—a preliminary report. Br J Neurosurg 8:743-45PubMed View Article
    4.Rawlins JM, Batchelor AG, Liddington MI et al (2004) Tumor excision and reconstruction of the upper cervical spine: a multidisciplinary approach. Plast Reconstr Surg 114:1534-538PubMed View Article
    5.Guppy KH, Chakrabarti I, Isaacs RS et al (2013) En bloc resection of a multilevel high-cervical chordoma involving C-2: new operative modalities: technical note. J Neurosurg Spine 19:232-42PubMed View Article
    6.Rhines LD, Fourney DR, Siadati A et al (2005) En?bloc?resection?of?multilevel?cervical chordoma?with C-2 involvement. Case report and description of operative technique. J Neurosurg Spine 2:199-05PubMed View Article
    7.Goertzen DJ, Kawchuk GN (2009) A novel application of velocity-based force control for use in robotic biomechanical testing. J Biomech 42:366-69PubMed View Article
    8.Panjabi M, Dvorak J, Duranceau J et al (1988) Three-dimensional movements of the upper cervical spine. Spine 13:726-30PubMed View Article
    9.Panjabi MM, Crisco JJ, Vasavada A et al (2001) Mechanical properties of the human cervical spine as shown by three-dimensional load-displacement curves. Spine 26:2692-700PubMed View Article
    10.Sar C, Eralp L (2001) Transoral resection and reconstruction for primary osteogenic sarcoma of the second cervical vertebra. Spine 26:1936-941PubMed View Article
    11.Bailey CS, Fisher CG, Boyd MC et al (2006) En bloc marginal excision of a multilevel cervical chordoma. Case report. J Neurosurg Spine 4:409-14PubMed View Article
    12.Wei F, Liu ZJ, Liu XG et al (2014) Complications of total spondylectomy of upper cervical spine primary tumor. Chin J Spine Spinal Cord 24:227-33
    13.Ji W, Wang XY, Xu HZ et al (2012) The anatomic study of clival screw fixation for the craniovertebral region. Eur Spine J 21:1483-491PubMed Central PubMed View Article
    14.Luc PC, Carl EA, Guy G (2007) Biomechanical study of anterior spinal instrumentation configurations. Eur Spine J 16:1039-045View Article
    15.Muffoletto AJ, Yang J, Vadhva M et al (2003) Cervical stability with lateral mass plating: unicortical versus bicortical screw purchase. Spine 28:778-81PubMed
    16.Singh H, Harrop J, Schiffmacher P et al (2010) Ventral surgical approaches to craniovertebral junction chordomas. Neurosurgery 66(3 Suppl):96-03PubMed View Article
    17.Crockard HA (1995) Transoral surgery: some lessons learned. Br J Neurosurg 9:283-93PubMed View Article
    18.Menezes AH (2008) Surgical approaches: postoperative care and complications “transoral-transpalatopharyngeal approach to the craniocervical junction- Childs Nerv Syst 24:1187-193PubMed View Article
    19.Menezes AH, VanGilder JC (1988) Transoral-transpharyngeal approach to the anterior craniocervical junction: ten-year experience with 72 patients. J Neurosurg 69:895-03PubMed View Article
    20.Neo M, Asato R, Honda K et al (2007) Transmaxillary and transmandibular approach to a C1 chordoma. Spine 32:E236–E239PubMed View Article
    21.Park SH, Sung JK, Lee SH et al (2007) High?anterior?cervical?approach?to the upper?cervical spine. Surg Neurol 68:519-24PubMed View Article
    22.Cavallo LM, Cappabianca P, Messina A et al (2007) The?extended?endoscopic?endonasal?approach to the?clivus?and cranio-vertebral junction: anatomical study. Childs Nerv Syst 23:665-71PubMed View Article
    23.Wang Y, Xu W, Yang XH et al (2013) Recurrent upper cervical chordomas after radiotherapy surgical outcomes and surgical approach selection based on complications. Spine 38:E1141–E1148PubMed View Article
    24.Chibbaro S, Cornelius JF, Froelich S et al (2014) Endoscopic endonasal approach in the management of skull base chordomas-clinical experience on a large series, technique, outcome, and pitfalls. Neurosurg Rev 37:217-24PubMed View Article
  • 作者单位:Wei Ji (1)
    Jie Tong (1)
    Zhiping Huang (1)
    Minghui Zheng (1)
    Xiuhua Wu (1)
    Jianting Chen (1)
    Qingan Zhu (1)

    1. Department of Spinal Surgery, Nanfang Hospital, Southern Medical University, 1838 North Guangzhou Avenue, Guangzhou, China
  • 刊物类别:Medicine
  • 刊物主题:Medicine & Public Health
    Surgical Orthopedics
    Neurosurgery
  • 出版者:Springer Berlin / Heidelberg
  • ISSN:1432-0932
文摘
Purpose A fabricated mesh cage and/or posterior occipitocervical instrumentation alone has been used for reconstruction of ventral defect of the upper cervical spine. However, using a trimmed mesh cage it was hard to achieve optimal clival screw purchase and it migrated or broke. A specific instrumentation at the craniovertebral junction (CVJ) should incorporate the morphology of the CVJ and biomechanical validation. The purpose of the present study was to develop an innovative clivus plate integrated with the clinical anatomy of CVJ and to evaluate the stability of the clivus plate fixation (CPF), stand-alone or combined with a posterior occipitocervical fixation (POCF). Methods Dimensions relevant to the clivus plate were measured on 40 adult dry bones and CT images of 30 patients. The CPF was composed of the clivus plate and a titanium mesh cage. The clivus plate was anchored to the clivus, atlas and C3 body and connected to the mesh cage. Six fresh cadaveric head–neck specimens (Oc–C4) were used in this study (46?±?15?years old, 2?F/4?M). A continuous pure moment of? ±1.5?Nm was applied to the specimen in flexion, extension, lateral bending and axial rotation. The status of intact, CPF alone, and CPF plus POCF was tested on each specimen. The CPF was implanted to the specimen following resection of the C1 anterior arch, C2 vertebral body, C2–C3 disc and atlantoaxial ligaments. The POCF was applied with screws anchoring at the occiput, C1, C3 and C4. The range of motion (ROM) and neutral zone (NZ) from the occiput to C3 were calculated. Results The clivus plate was developed based on measurements of 40 adult dry bones and CT images of 30 patients. The plates were successfully applied to all specimens. No obvious loosening or mismatch was observed. The mean clival length and widest and narrowest diameter of the clivus were 26, 33 and 19?mm, respectively. The clivus screw length was 8?mm for the caudal holes and 10?mm for the cephalad hole. The CPF reduced ROMs to 3.9° in flexion, 2.8° in extension, 4.2° in lateral bending and 6.8° in axial rotation. The combined CPF and POCF constrained motion within 0.6° in all directions and more than the CPF (P?<?0.05). NZs after the CPF were 1.0° in flexion–extension, 2.1° in lateral bending and 2.2° in axial rotation, respectively. NZs after the CPF plus POCF were within 0.2° in all directions and less than the CPF (P?<?0.05). Conclusion This study demonstrated screw purchase in the adult clivus and developed an innovative clivus plate fixation for reconstructing an extensive ventral defect in the upper cervical spine. The clivus plate fixation combined a posterior instrumentation ensuring reliable upper cervical stability.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700